libata: allow ->probe_reset to return ATA_DEV_UNKNOWN
PATCH 1/1 libata: allow ->probe_reset to return ATA_DEV_UNKNOWN
[PATCH] libata: allow ->probe_reset to return ATA_DEV_UNKNOWN
This patch makes ata_bus_probe() normalize classes[] returned by ->probe_reset such that ->probe_reset can return ATA_DEV_UNKNOWN. This eases implementation of ->probe_reset's which don't directly use ata_drive_probe_reset().
Signed-off-by Tejun Heo <[email protected]>
drivers/scsi/libata-core.c +4 -1
@@ -1142,8 +1142,11 @@ static int ata_bus_probe(struct ata_port rc = ap->ops->probe_reset (ap, classes);if (rc ==0 ) { -for (i =0 ; i <ATA_MAX_DEVICES ; i++) +for (i =0 ; i <ATA_MAX_DEVICES ; i++) { +if (classes[i] ==ATA_DEV_UNKNOWN ) + classes[i] =ATA_DEV_NONE ; ap->device[i].class = classes[i]; + } }else {printk (KERN_ERR "ata%u: probe reset failed, " "disabling port\n" , ap->id);
Jeff Garzik
AppliedQuoted 8 lines · Tejun Heo
[PATCH] libata: allow ->probe_reset to return
ATA_DEV_UNKNOWNThis patch makes
ata_bus_probe()normalize classes[] returned by ->probe_reset such that ->probe_reset can returnATA_DEV_UNKNOWN. This eases implementation of ->probe_reset's which don't directly useata_drive_probe_reset().Signed-off-by Tejun Heo <[email protected]>
applied