IBM DS4300
Hi list,
I have the following SAN hardware, and would be very grateful for any help:
SAN:
IBM DS4300 Storage Server with Turbo Option
HBA:
Fast Host Bus Adapter FC-2
Switch:
2 IBM TotalStorage SAN Switch H08 (8-portas)
Does multipath-tools support this hardware? How should I configure it?
I have tried to use multipath with it, using default configuration, but I am having performance problems. What I would like to figure out is if multipath-tools has anything to do with it.
Best regards,
Gil
Gil,
DS4300 has two modes:
AVT, which means only one path can be used at any point in time. Using an alternate path will cause Automated Volume Transfer and add significant latency.
RDAC, which means only one path can be used at any point in time. Using an alternate path will cause an I/O error unless the volume has been migrated manually or by a hardware_handler.
Best Regards
Holger Smolinski
--
Dr. Holger Smolinski, Linux Technology Center, Linux on zSeries Author of the '-t2'-Option
IBM Deutschland Entwicklung GmbH,Schönaicher Str. 220, 71032 Böblingen
FAX: +49-7031-16-3456, Tel. +49-7031-16-4652
"Gil"
<[email protected]>
Sent by: To
dm-devel-bounces@ <[email protected]>
redhat.com cc
Subject
29.05.2006 19:42 [dm-devel] IBM DS4300
Please respond to
device-mapper
development
<dm-devel@redhat.
com> Hi list,
I have the following SAN hardware, and would be very grateful for any help:
SAN:
IBM DS4300 Storage Server with Turbo Option
HBA:
Fast Host Bus Adapter FC-2
Switch:
2 IBM TotalStorage SAN Switch H08 (8-portas)
Does multipath-tools support this hardware? How should I configure it?
I have tried to use multipath with it, using default configuration, but I am having performance problems. What I would like to figure out is if multipath-tools has anything to do with it.
Best regards,
Gil--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel
Quoted 11 lines · Holger Smolinski
Gil,
DS4300 has two modes:
AVT, which means only one path can be used at any point in time. Using an alternate path will cause Automated Volume Transfer and add significant latency.
RDAC, which means only one path can be used at any point in time. Using an alternate path will cause an I/O error unless the volume has been migrated manually or by ahardware_handler.
And you _really_ will want to use AVT. RDAC mode is currently _not_ supported by multipath-tools.
For AVT mode you should use the pp_tpc prioritizer.
Cheers,
Hannes
Signature · 4 lines
Dr. Hannes Reinecke [email protected] SuSE Linux Products GmbH S390 & zSeries Maxfeldstraße 5 +49 911 74053 688 90409 Nürnberg http://www.suse.de