HP XP devinfo update
Hi all,
we've had some bug reports that the sequential scanning fails with HP XP arrays. Fancy, though, as (according to HP) those boxes support REPORT_LUN.
This patch updates the blacklist to always use REPORT_LUN scan on HP XP arrays.
Please apply.
Cheers,
Hannes
Signature · 4 lines
Dr. Hannes Reinecke [email protected] SuSE Linux Products GmbH S390 & zSeries Maxfeldstraße 5 +49 911 74053 688 90409 Nürnberg http://www.suse.de
HP XP array devinfo update
According to Anthony Cheung all HP XP arrays with "OPEN-" types support REPORT_LUN. So there is no reason why we shouldn't use it.
Signed-off-by Anthony Cheung <[email protected]>
Signed-off-by Hannes Reinecke <[email protected]>
drivers/scsi/scsi_devinfo.c +1 -1
@@ -160,7 +160,7 @@ static struct { {"HITACHI", "DISK-SUBSYSTEM", "*", BLIST_ATTACH_PQ3 | BLIST_SPARSELUN | BLIST_LARGELUN}, {"HITACHI", "OPEN-E", "*", BLIST_ATTACH_PQ3 | BLIST_SPARSELUN | BLIST_LARGELUN}, {"HP", "A6189A", NULL, BLIST_SPARSELUN | BLIST_LARGELUN}, /* HP VA7400 */ - {"HP", "OPEN-", "*", BLIST_SPARSELUN | BLIST_LARGELUN}, /* HP XP Arrays */ + {"HP", "OPEN-", "*", BLIST_REPORTLUN2}, /* HP XP Arrays */ {"HP", "NetRAID-4M", NULL, BLIST_FORCELUN}, {"HP", "HSV100", NULL, BLIST_REPORTLUN2 | BLIST_NOSTARTONADD}, {"HP", "C1557A", NULL, BLIST_FORCELUN},