Skip to contentSkip to conversation

Vendor field with USB, [SP]ATA etc-attached disks

DISCUSSION Michael Tokarev 3 participants 5 messages Sep 11, 2006 – Sep 13, 2006

lore
Share & tools
lore
#0 lore raw

With current SATA, PATA and at least some USB disks, Linux reports Vendor: $subsystem, instead of the actual vendor of the drive, like this:

scsi1 : ata_piix
Vendor: ATA Model: ST3808110AS Rev: n/a
Type: Direct-Access ANSI SCSI revision: 05

This should be Vendor: Seagate, not ATA (Note also the lack of "Revision" field). The same for PATA disk:

scsi0 : pata_via
Vendor: ATA Model: ST3120026A Rev: 3.76
Type: Direct-Access ANSI SCSI revision: 05

The same is shown in /sys/block/$DEV/device/vendor.

Can it be changed to show real vendor, instead of the subsystem name?

Thanks.

/mjt

#1 lore raw
Quoted 11 lines · Michael Tokarev

With current SATA, PATA and at least some USB disks, Linux reports Vendor: $subsystem, instead of the actual vendor of the drive, like this:

scsi1 : ata_piix
Vendor: ATA Model: ST3808110AS Rev: n/a
Type: Direct-Access ANSI SCSI revision: 05

This should be Vendor: Seagate, not ATA (Note also the lack of "Revision" field). The same for PATA disk:

Quoted 7 lines

scsi0 : pata_via
Vendor: ATA Model: ST3120026A Rev: 3.76
Type: Direct-Access ANSI SCSI revision: 05

The same is shown in /sys/block/$DEV/device/vendor.

Can it be changed to show real vendor, instead of the subsystem name?

No. Two reasons:

* ATA doesn't export the vendor separate from the model, and in some cases (Seagate) it isn't present at all, anywhere.
* "ATA" vendor string is the standardized value to put in that field, according to the SCSI T10 specifications.

Jeff

#2 lore raw
Quoted 16 lines · Jeff Garzik
Quoted 15 lines · Michael Tokarev

With current SATA, PATA and at least some USB disks, Linux reports Vendor: $subsystem, instead of the actual vendor of the drive, like this:

scsi1 : ata_piix
Vendor: ATA Model: ST3808110AS Rev: n/a
Type: Direct-Access ANSI SCSI revision: 05

This should be Vendor: Seagate, not ATA (Note also the lack of "Revision" field). The same for PATA disk:

scsi0 : pata_via
Vendor: ATA Model: ST3120026A Rev: 3.76
Type: Direct-Access ANSI SCSI revision: 05

Quoted 8 lines
Quoted 3 lines

The same is shown in /sys/block/$DEV/device/vendor.

Can it be changed to show real vendor, instead of the subsystem name?

No. Two reasons:

* ATA doesn't export the vendor separate from the model, and in some cases (Seagate) it isn't present at all, anywhere.
* "ATA" vendor string is the standardized value to put in that field, according to the SCSI T10 specifications.

To add a small detail. The reason it's printed that way is because libata (the new ATA driver) emulates SCSI device at the moment, so it has to fake SCSI vendor ID and model string, which BTW is shorter than ATA string and thus truncated in some cases. The vendor ID "ATA" is defined in SAT (SCSI ATA translation) standard, IIRC.

For the time being, we'll have to live with boilerplate ATA vendor and truncated vendor ID. There are plans to make libata independent from SCSI which should solve the problem but it will take quite some time.

Signature · 1 line
tejun
#3 lore raw
Quoted 1 line · Tejun Heo

For the time being, we'll have to live with boilerplate ATA vendor and truncated vendor ID. There are plans to make libata independent from

Truncated model ID, I presume you mean.

Quoted 1 line

SCSI which should solve the problem but it will take quite some time.

Since ATA does not distinguish between vendor and model, you can't really solve the problem. Two high volume disk vendors don't bother to put a vendor name in the model string at all.

Jeff

#4 lore raw
Quoted 4 lines · Jeff Garzik
Quoted 1 line · Tejun Heo

For the time being, we'll have to live with boilerplate ATA vendor and truncated vendor ID. There are plans to make libata independent from

Truncated model ID, I presume you mean.

Yeap.

Quoted 3 lines
Quoted 1 line

SCSI which should solve the problem but it will take quite some time.

Since ATA does not distinguish between vendor and model, you can't really solve the problem. Two high volume disk vendors don't bother to put a vendor name in the model string at all.

I meant by being solved "not printing emulated SCSI stuff including vendor ID while printing model ID fully and other ATA stuff".

Signature · 1 line
tejun