hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow USB and MPS Flow
Aleksa Savic
maintainercover hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow USB and MPS Flow
This series adds support for the Aquacomputer High Flow USB and MPS Flow flow sensor devices, which communicate through a proprietary USB protocol.
Patch 1 resolves the case when devices that communicate through the legacy way (such as these) don't contain a reading for a sensor, in which case -ENODATA is now returned.
Patch 2 adds support for the devices and implements reading their temperature and flow sensors.
Aleksa Savic (2):
hwmon: (aquacomputer_d5next) Check if temp sensors of legacy devices
are connected
hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow
USB and MPS Flow
Documentation/hwmon/aquacomputer_d5next.rst | 7 ++ drivers/hwmon/aquacomputer_d5next.c | 72 +++++++++++++++++++-- 2 files changed, 74 insertions(+), 5 deletions(-)
Signature · 1 line
2.41.0
Aleksa Savic
maintainerPATCH 1/2 hwmon: (aquacomputer_d5next) Check if temp sensors of legacy devices are connected
Return -ENODATA if a temp sensor of a legacy device does not contain a reading.
Originally-from: Leonard Anderweit <[email protected]>
--- drivers/hwmon/aquacomputer_d5next.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-)
drivers/hwmon/aquacomputer_d5next.c +4 -1
@@ -926,7 +926,10 @@ static int aqc_legacy_read(struct aqc_data *priv)for (i =0 ; i < priv->num_temp_sensors; i++) { sensor_value =get_unaligned_le16 (priv->buffer + priv->temp_sensor_start_offset + i *AQC_SENSOR_SIZE ); - priv->temp_input[i] = sensor_value *10 ; +if (sensor_value ==AQC_SENSOR_NA ) + priv->temp_input[i] = -ENODATA ; +else + priv->temp_input[i] = sensor_value *10 ; }/* Special-case sensor readings */
Signature · 1 line
2.41.0
Guenter Roeck
maintainerRe: [PATCH 1/2] hwmon: (aquacomputer_d5next) Check if temp sensors of legacy devices are connected
Quoted 3 lines · Aleksa Savic
Return
-ENODATAif a temp sensor of a legacy device does not contain a reading.
Why is the sensor instantiated in the first place ? Returning -ENODATA for every reading is not desirable. If this can happen, the is_visible function should check for it and skip affected sensors.
Guenter
Quoted 22 lines
Originally-from: Leonard Anderweit <[email protected]>
Signed-off-by Aleksa Savic <[email protected]>--- drivers/hwmon/aquacomputer_d5next.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-)drivers/hwmon/aquacomputer_d5next.c +4
-1@@ -926,7 +926,10 @@ static int aqc_legacy_read(struct aqc_data *priv)for (i =0 ; i < priv->num_temp_sensors; i++) { sensor_value =get_unaligned_le16 (priv->buffer + priv->temp_sensor_start_offset + i *AQC_SENSOR_SIZE ); - priv->temp_input[i] = sensor_value *10 ; +if (sensor_value ==AQC_SENSOR_NA ) + priv->temp_input[i] = -ENODATA ; +else + priv->temp_input[i] = sensor_value *10 ; }/* Special-case sensor readings */
Aleksa Savic
maintainerRe: [PATCH 1/2] hwmon: (aquacomputer_d5next) Check if temp sensors of legacy devices are connected
Quoted 8 lines · Guenter Roeck
Why is the sensor instantiated in the first place ? Returning
-ENODATAfor every reading is not desirable. If this can happen, theis_visiblefunction should check for it and skip affected sensors.Guenter
The external temp sensor(s) are hot-swappable and can be plugged or unplugged anytime. Similar logic already exists in aqc_raw_event() for the sensors.
Thanks,
Aleksa
Aleksa Savic
maintainerPATCH 2/2 hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow USB and MPS Flow
In reply to Aleksa SavicExtend aquacomputer_d5next driver to expose various hardware sensors of the Aquacomputer High Flow USB flow sensor, which communicates through a proprietary USB HID protocol. This commit also adds support for the sensors of the MPS Flow devices, as they have the same USB product ID and sensor layouts. Implemented by Leonard Anderweit [1].
Internal and external temp sensor readings are available, along with the flow sensor.
Additionally, serial number and firmware version are exposed through debugfs.
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/90
Originally-from: Leonard Anderweit <[email protected]>
--- Documentation/hwmon/aquacomputer_d5next.rst | 7 +++ drivers/hwmon/aquacomputer_d5next.c | 67 +++++++++++++++++++-- 2 files changed, 70 insertions(+), 4 deletions(-)
Documentation/hwmon/aquacomputer_d5next.rst +7 -0
@@ -16,6 +16,8 @@ Supported devices: * Aquacomputer Aquastream XT watercooling pump * Aquacomputer Aquastream Ultimate watercooling pump * Aquacomputer Poweradjust 3 fan controller +* Aquacomputer High Flow USB flow meter +* Aquacomputer MPS Flow devices Author: Aleksa Savic
@@ -73,6 +75,11 @@ It also exposes pressure and flow speed readings. The Poweradjust 3 controller exposes a single external temperature sensor. +The High Flow USB exposes an internal and external temperature sensor, and a flow meter. + +The MPS Flow devices expose the same entries as the High Flow USB because they have +the same USB product ID and report sensors equivalently. + Depending on the device, not all sysfs and debugfs entries will be available. Writing to virtual temperature sensors is not currently supported.
drivers/hwmon/aquacomputer_d5next.c +63 -4
140 lines not on this page · raw message
Signature · 1 line
2.41.0
Quoted 9 lines · Aleksa Savic
Extend
aquacomputer_d5nextdriver to expose various hardware sensors of the Aquacomputer High Flow USB flow sensor, which communicates through a proprietary USB HID protocol. This commit also adds support for the sensors of the MPS Flow devices, as they have the same USB product ID and sensor layouts. Implemented by Leonard Anderweit [1].Internal and external temp sensor readings are available, along with the flow sensor.
Quoted 7 lines
Additionally, serial number and firmware version are exposed through debugfs.
[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/90
Originally-from: Leonard Anderweit <[email protected]>
Signed-off-by Aleksa Savic <[email protected]>
Applied.
Thanks,
Guenter
Quoted 185 lines
--- Documentation/hwmon/aquacomputer_d5next.rst | 7 +++ drivers/hwmon/aquacomputer_d5next.c | 67 +++++++++++++++++++-- 2 files changed, 70 insertions(+), 4 deletions(-)Documentation/hwmon/aquacomputer_d5next.rst +7
-0@@ -16,6 +16,8 @@ Supported devices: * Aquacomputer Aquastream XT watercooling pump * Aquacomputer Aquastream Ultimate watercooling pump * Aquacomputer Poweradjust 3 fan controller +* Aquacomputer High Flow USB flow meter +* Aquacomputer MPS Flow devices Author: Aleksa Savic@@ -73,6 +75,11 @@ It also exposes pressure and flow speed readings. The Poweradjust 3 controller exposes a single external temperature sensor. +The High Flow USB exposes an internal and external temperature sensor, and a flow meter. + +The MPS Flow devices expose the same entries as the High Flow USB because they have +the same USB product ID and report sensors equivalently. + Depending on the device, not all sysfs and debugfs entries will be available. Writing to virtual temperature sensors is not currently supported.drivers/hwmon/aquacomputer_d5next.c +63
-4@@ -1,11 +1,12 @@// SPDX-License-Identifier: GPL-2.0+ /* * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo, -* Quadro, High Flow Next, Aquaero, Aquastream Ultimate, Leakshield) +* Quadro, High Flow Next, Aquaero, Aquastream Ultimate, Leakshield, +* High Flow USB/MPS Flow family) * * Aquacomputer devices send HID reports (with ID 0x01) every second to report * sensor values, except for devices that communicate through the -* legacy way (currently, Poweradjust 3). +* legacy way (currently, Poweradjust 3 and High Flow USB/MPS Flow family). * * Copyright 2021 Aleksa Savic <[email protected]> * Copyright 2022 Jack Doan <[email protected]> @@ -35,11 +36,12 @@#define USB_PRODUCT_ID_AQUASTREAMXT 0xf0b6#define USB_PRODUCT_ID_AQUASTREAMULT 0xf00b#define USB_PRODUCT_ID_POWERADJUST3 0xf0bd +#define USB_PRODUCT_ID_HIGHFLOW 0xf003enum kinds { d5next, farbwerk, farbwerk360, octo, quadro, highflownext, aquaero, poweradjust3, aquastreamult, - aquastreamxt, leakshield + aquastreamxt, leakshield, highflow };static const char *const aqc_device_names[] = {@@ -53,7 +55,8 @@ static const char *const aqc_device_names[] = { [aquastreamxt] = "aquastreamxt", [aquaero] = "aquaero", [aquastreamult] = "aquastreamultimate", - [poweradjust3] = "poweradjust3" + [poweradjust3] = "poweradjust3", + [highflow] = "highflow" /* Covers MPS Flow devices */ };#define DRIVER_NAME "aquacomputer_d5next"@@ -90,6 +93,8 @@ static u8 aquaero_secondary_ctrl_report[] = {#define POWERADJUST3_STATUS_REPORT_ID 0x03 +#define HIGHFLOW_STATUS_REPORT_ID 0x02 +/* Data types for reading and writing control reports */ #define AQC_8 0#define AQC_BE16 1@@ -282,6 +287,17 @@ static u16 aquastreamxt_sensor_fan_offsets[] = { 0x13, 0x1b };/* Sensor report offsets for the Poweradjust 3 */ #define POWERADJUST3_SENSOR_START 0x03 +/* Specs of the High Flow USB */ +#define HIGHFLOW_NUM_SENSORS 2 +#define HIGHFLOW_NUM_FLOW_SENSORS 1 +#define HIGHFLOW_SENSOR_REPORT_SIZE 0x76 + +/* Sensor report offsets for the High Flow USB */ +#define HIGHFLOW_FIRMWARE_VERSION 0x3 +#define HIGHFLOW_SERIAL_START 0x9 +#define HIGHFLOW_FLOW_SENSOR_OFFSET 0x23 +#define HIGHFLOW_SENSOR_START 0x2b +/* Labels for D5 Next */ static const char *const label_d5next_temp[] = {"Coolant temp" @@ -486,6 +502,16 @@ static const char *const label_poweradjust3_temp_sensors[] = {"External sensor" }; +/* Labels for Highflow */ +static const char *const label_highflow_temp[] = { +"External temp" , +"Internal temp" +}; + +static const char *const label_highflow_speeds[] = { +"Flow speed [dL/h]" +}; +struct aqc_fan_structure_offsets {u8 voltage;u8 curr;@@ -819,6 +845,7 @@ static umode_t aqc_is_visible(const void *data, enum hwmon_sensor_types type, u3break ;case aquaero:case quadro: +case highflow:/* Special case to support flow sensors */ if (channel < priv->num_fans + priv->num_flow_sensors)return 0444 ;@@ -965,6 +992,17 @@ static int aqc_legacy_read(struct aqc_data *priv) sensor_value =get_unaligned_le16 (priv->buffer +AQUASTREAMXT_FAN_VOLTAGE_OFFSET ); priv->voltage_input[1 ] =DIV_ROUND_CLOSEST (sensor_value *1000 ,63 );break ; +case highflow: +/* Info provided with every report */ + priv->serial_number[0 ] =get_unaligned_le16 (priv->buffer + + priv->serial_number_start_offset); + priv->firmware_version = +get_unaligned_le16 (priv->buffer + priv->firmware_version_offset); + +/* Read flow speed */ + priv->speed_input[0 ] =get_unaligned_le16 (priv->buffer + + priv->flow_sensors_start_offset); +break ;default :break ; }@@ -1750,6 +1788,20 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) priv->temp_label = label_poweradjust3_temp_sensors;break ; +case USB_PRODUCT_ID_HIGHFLOW : + priv->kind = highflow; + + priv->num_fans =0 ; + + priv->num_temp_sensors =HIGHFLOW_NUM_SENSORS ; + priv->temp_sensor_start_offset =HIGHFLOW_SENSOR_START ; + priv->num_flow_sensors =HIGHFLOW_NUM_FLOW_SENSORS ; + priv->flow_sensors_start_offset =HIGHFLOW_FLOW_SENSOR_OFFSET ; + priv->buffer_size =HIGHFLOW_SENSOR_REPORT_SIZE ; + + priv->temp_label = label_highflow_temp; + priv->speed_label = label_highflow_speeds; +break ;default :break ; }@@ -1775,6 +1827,12 @@ static int aqc_probe(struct hid_device *hdev, const struct hid_device_id *id) priv->status_report_id =AQUASTREAMXT_STATUS_REPORT_ID ;break ; +case highflow: + priv->serial_number_start_offset =HIGHFLOW_SERIAL_START ; + priv->firmware_version_offset =HIGHFLOW_FIRMWARE_VERSION ; + + priv->status_report_id =HIGHFLOW_STATUS_REPORT_ID ; +break ;default : priv->serial_number_start_offset =AQC_SERIAL_START ; priv->firmware_version_offset =AQC_FIRMWARE_VERSION ;@@ -1849,6 +1907,7 @@ static const struct hid_device_id aqc_table[] = { { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_AQUASTREAMXT) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_AQUASTREAMULT) }, { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_POWERADJUST3) }, + { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_HIGHFLOW) }, { } };
Aleksa Savic
maintainerQuoted 6 lines · Guenter Roeck
Applied.
Thanks,
Guenter
Thanks. Maybe I'm missing something, why is the first patch from the series not applied as well?
Aleksa
Guenter Roeck
maintainerQuoted 11 lines · Aleksa Savic
Quoted 6 lines · Guenter Roeck
Applied.
Thanks,
GuenterThanks. Maybe I'm missing something, why is the first patch from the series not applied as well?
Because I missed your reply to my question. Sorry, I have to admit that I am less than perfect. Applied now.
Guenter
Aleksa Savic
maintainerQuoted 9 lines · Guenter Roeck
Quoted 8 lines · Aleksa Savic
Quoted 6 lines · Guenter Roeck
Applied.
Thanks,
Guenter
Quoted 9 lines
Quoted 3 lines
Thanks. Maybe I'm missing something, why is the first patch from the series not applied as well?
Because I missed your reply to my question. Sorry, I have to admit that I am less than perfect. Applied now.
Guenter
Thank you, much appreciated :)
Aleksa