RT-Socket-CAN bus error rate and latencies
Hello,
on the Xenomai mailing list the topic "bus error flooding" popped up again. Various users reported trouble due to high bus error rates and bad impact on latencies. Some discussion is going on on how to avoid such flooding. I have already implemented "on-demand" bus error interrupts. Bus error interrupts are then only enabled when at least one socket is listening on bus errors. But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
To have some input, I have measured the bus error rate with the PEAK PCAN PCI card on my Icecube MPC5200 eval-board doing rtcansend without cable connected. Here are the results for the various baud-rates:
125 KB/s 1926 BEI/s 250 KB/s 3925 BEI/s 500 KB/s 7856 BEI/s
1000 KB/s 15700 BEI/s
The latency measured with "latency" from the testsuite reported an increase of the latency with load from 67 to 95us almost independently of the baud-rate. Sending messages with 8 byte payload from MSCAN to SJA1000 on the same node as fast as possible increased the latency up to 103us. This measurement did not include delivery of messages to sockets (actually no socket was listening).
Wolfgang.
Quoted 14 lines · Wolfgang Grandegger
Hello,
on the Xenomai mailing list the topic "bus error flooding" popped up again. Various users reported trouble due to high bus error rates and bad impact on latencies. Some discussion is going on on how to avoid such flooding. I have already implemented "on-demand" bus error interrupts. Bus error interrupts are then only enabled when at least one socket is listening on bus errors. But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
Quoted 8 lines
To have some input, I have measured the bus error rate with the PEAK PCAN PCI card on my Icecube MPC5200 eval-board doing rtcansend without cable connected. Here are the results for the various baud-rates:
125 KB/s 1926 BEI/s 250 KB/s 3925 BEI/s 500 KB/s 7856 BEI/s1000 KB/s 15700 BEI/s
So bus errors come in at a rate comparable to shortest possible frames at maximum speed, right? That's an IRQ load you can live with - if you plan to load your CAN bus at 100% anyway. But if you don't...
Quoted 8 lines
The latency measured with "latency" from the testsuite reported an increase of the latency with load from 67 to 95us almost independently of the baud-rate. Sending messages with 8 byte payload from MSCAN to SJA1000 on the same node as fast as possible increased the latency up to 103us. This measurement did not include delivery of messages to sockets (actually no socket was listening).
Some dump of /proc/xenomai/stat would be interesting (system load in both cases).
Jan
Quoted 19 lines · Jan Kiszka
Quoted 18 lines · Wolfgang Grandegger
Hello,
on the Xenomai mailing list the topic "bus error flooding" popped up again. Various users reported trouble due to high bus error rates and bad impact on latencies. Some discussion is going on on how to avoid such flooding. I have already implemented "on-demand" bus error interrupts. Bus error interrupts are then only enabled when at least one socket is listening on bus errors. But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
To have some input, I have measured the bus error rate with the PEAK PCAN PCI card on my Icecube MPC5200 eval-board doing rtcansend without cable connected. Here are the results for the various baud-rates:
Quoted 8 lines
Quoted 4 lines
125 KB/s 1926 BEI/s 250 KB/s 3925 BEI/s 500 KB/s 7856 BEI/s1000 KB/s 15700 BEI/s
So bus errors come in at a rate comparable to shortest possible frames at maximum speed, right? That's an IRQ load you can live with - if you plan to load your CAN bus at 100% anyway. But if you don't...
Yes, it looks like.
Quoted 10 lines
Quoted 7 lines
The latency measured with "latency" from the testsuite reported an increase of the latency with load from 67 to 95us almost independently of the baud-rate. Sending messages with 8 byte payload from MSCAN to SJA1000 on the same node as fast as possible increased the latency up to 103us. This measurement did not include delivery of messages to sockets (actually no socket was listening).
Some dump of
/proc/xenomai/statwould be interesting (system load in both cases).
OK, here for bus error flooding at 1MB/s:
bash-2.05b# cat /proc/xenomai/stat
CPU PID MSW CSW PF STAT %CPU NAME 0 0 0 9781211 0 00500080 74.0 ROOT 0 27199 130 264 0 00300182 0.0 display-27197 0 27200 0 260166 0 00300184 8.1 sampling-27197 0 0 0 29325916 0 00000000 14.5 IRQ0: SJA1000 0 0 0 0 0 00000000 0.0 IRQ0: SJA1000 0 0 0 1000002 0 00000000 0.0 IRQ55: MSCAN 0 0 0 0 0 00000000 0.0 IRQ56: MSCAN 0 0 0 9685429 0 00000000 3.0 IRQ256: [timer]
and here for "rtcansend -d 0 -l 1000000 rtcan0 1 2 3 4 5 6 7":
bash-2.05b# cat /proc/xenomai/stat
CPU PID MSW CSW PF STAT %CPU NAME 0 0 0 10377571 0 00500080 51.5 ROOT 0 27199 336 816 0 00300182 0.0 display-27197 0 27200 0 672738 0 00300184 5.8 sampling-27197 0 29526 0 291678 0 00300182 23.6 rtcansend-29526 0 0 0 30863047 0 00000000 9.7 IRQ0: SJA1000 0 0 0 0 0 00000000 0.0 IRQ0: SJA1000 0 0 0 1242608 0 00000000 6.5 IRQ55: MSCAN 0 0 0 0 0 00000000 0.0 IRQ56: MSCAN 0 0 0 10115159 0 00000000 2.1 IRQ256: [timer]
Wolfgang.
Quoted 4 lines · Wolfgang Grandegger
Hello,
on the Xenomai mailing list the topic "bus error flooding" popped up again. Various users reported trouble due to high bus error rates and bad impact on latencies. Some discussion is going on on how to avoid such flooding. I have already implemented "on-demand" bus error interrupts. Bus error interrupts are then only enabled when at least one socket is listening on bus errors. But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
What do you think about the following method?
config XENO_DRIVERS_CAN_SJA1000_BUS_ERR_LIMIT
depends on XENO_DRIVERS_CAN_SJA1000 int "Maximum number of successive bus errors" range 0 255
default 20
help
CAN bus errors are very useful for analyzing electrical problems but they can come at a very high rate resulting in interrupt flooding with bad impact on system performance and real-time behavior. This option, if greater than 0, will limit the amount of successive bus error interrupts. If the limit is reached, an error message with "can_id = CAN_ERR_BUSERR_FLOOD" is sent. The bus error counter gets reset on restart of the device and on any successful message transmission or reception. Be aware that bus error interrupts are only enabled if at least one socket is listening on bus errors.
I think it should make Sebastian and Jan happy, at least ;-).
Quoted 11 lines
To have some input, I have measured the bus error rate with the PEAK PCAN PCI card on my Icecube MPC5200 eval-board doing rtcansend without cable connected. Here are the results for the various baud-rates:
125 KB/s 1926 BEI/s 250 KB/s 3925 BEI/s 500 KB/s 7856 BEI/s1000 KB/s 15700 BEI/s
The latency measured with "latency" from the testsuite reported an increase of the latency with load from 67 to 95us almost independently of the baud-rate. Sending messages with 8 byte payload from MSCAN to SJA1000 on the same node as fast as possible increased the latency up to 103us. This measurement did not include delivery of messages to sockets (actually no socket was listening).
Wolfgang.
Wolfgang.
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 28 lines · Oliver Hartkopp
Quoted 14 lines · Wolfgang Grandegger
Quoted 3 lines · Wolfgang Grandegger
But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
What do you think about the following method?
config
XENO_DRIVERS_CAN_SJA1000_BUS_ERR_LIMIT
depends onXENO_DRIVERS_CAN_SJA1000int "Maximum number of successive bus errors" range 0 255
default 20
helpQuoted 12 lines
CAN bus errors are very useful for analyzing electrical problems
but they can come at a very high rate resulting in interrupt flooding with bad impact on system performance and real-time behavior. This option, if greater than 0, will limit the amount of successive bus error interrupts. If the limit is reached, an error message with "can_id=CAN_ERR_BUSERR_FLOOD" is sent. The bus error counter gets reset on restart of the device and on any successful message transmission or reception. Be aware that bus error interrupts are only enabled if at least one socket is listening on bus errors.
Quoted 3 lines
Hi Wolfgang,
what would be the wanted behaviour, after the discussed problem of bus error flooding occurred?
Well, I think the bus error rate should be downscaled without loosing vital information concerning the cause of the problem and it should require as little user intervention as possible. Treating it like a bus error as currently done in Socket-CAN is a bit to strong in my mind.
Quoted 1 line
Can the Controller be assumed to be 'slightly dead', or what? Is there any chance that the bus heals by itself (=> no more bus errors) and can be used in a normal way? Or is a user interaction recommended or _required_?
Yes, if you plug the cable, the bus errors might go away and the TX done interrupt will arrive or you get a bus-off (I have seen both).
Quoted 1 line
Indeed the slow down of bus errors is a reasonable approach, but your suggested method leaves too many questions open for the user :-/
What questions?
Quoted 5 lines
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
Thanks.
Wolfgang.
Quoted 66 lines · Wolfgang Grandegger
Quoted 31 lines · Oliver Hartkopp
Quoted 18 lines · Wolfgang Grandegger
Quoted 7 lines · Wolfgang Grandegger
But flooding can still occur and we
are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?What do you think about the following method?
config
XENO_DRIVERS_CAN_SJA1000_BUS_ERR_LIMIT
depends onXENO_DRIVERS_CAN_SJA1000int "Maximum number of successive bus errors" range 0 255
default 20
helpQuoted 12 lines
CAN bus errors are very useful for analyzing electrical problems
but they can come at a very high rate resulting in interrupt flooding with bad impact on system performance and real-time behavior. This option, if greater than 0, will limit the amount of successive bus error interrupts. If the limit is reached, an error message with "can_id=CAN_ERR_BUSERR_FLOOD" is sent. The bus error counter gets reset on restart of the device and on any successful message transmission or reception. Be aware that bus error interrupts are only enabled if at least one socket is listening on bus errors.Quoted 4 lines
Hi Wolfgang,
what would be the wanted behaviour, after the discussed problem of bus error flooding occurred?
Well, I think the bus error rate should be downscaled without loosing vital information concerning the cause of the problem and it should require as little user intervention as possible. Treating it like a bus error as currently done in Socket-CAN is a bit to strong in my mind.
Quoted 3 lines
Can the Controller be assumed to be 'slightly dead', or what? Is there any chance that the bus heals by itself (=> no more bus errors) and can be used in a normal way? Or is a user interaction recommended or _required_?
Yes, if you plug the cable, the bus errors might go away and the TX done interrupt will arrive or you get a bus-off (I have seen both).
Quoted 2 lines
Indeed the slow down of bus errors is a reasonable approach, but your suggested method leaves too many questions open for the user :-/
What questions?
Quoted 12 lines
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
Quoted 7 lines
Quoted 1 line
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop over the application:
After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.
Well, and if there is no thread listening on bus errors, but we want stats to be updated once in a while, a slow low-prio timer to re-enable BEI might still be created in the stack like Oliver suggested. For Xenomai, you could consider pending an rtdm_nrtsig to keep the impact on the RT domain low. But that's a minor implementation detail. The important point is to avoid uncontrolled error bursts, even over a short period (20 bus errors at 1 MBit/s already last for > 1 ms).
Jan
Quoted 57 lines · Jan Kiszka
Quoted 37 lines · Wolfgang Grandegger
Quoted 27 lines · Oliver Hartkopp
Quoted 14 lines · Wolfgang Grandegger
Quoted 3 lines · Wolfgang Grandegger
But flooding can still occur and we are thinking about a better way of downscaling or temporarily disabling them. Socket-CAN currently restarts the controller after 200 bus errors. My preferred solution for RT-Socket-CAN currently is to stop the CAN controller after a kernel configurable amount of successive bus errors. More clever ideas and comments are welcome?
What do you think about the following method?
config
XENO_DRIVERS_CAN_SJA1000_BUS_ERR_LIMIT
depends onXENO_DRIVERS_CAN_SJA1000int "Maximum number of successive bus errors" range 0 255
default 20
helpQuoted 12 lines
CAN bus errors are very useful for analyzing electrical problems
but they can come at a very high rate resulting in interrupt flooding with bad impact on system performance and real-time behavior. This option, if greater than 0, will limit the amount of successive bus error interrupts. If the limit is reached, an error message with "can_id=CAN_ERR_BUSERR_FLOOD" is sent. The bus error counter gets reset on restart of the device and on any successful message transmission or reception. Be aware that bus error interrupts are only enabled if at least one socket is listening on bus errors.Quoted 3 lines
Hi Wolfgang,
what would be the wanted behaviour, after the discussed problem of bus error flooding occurred?
Well, I think the bus error rate should be downscaled without loosing vital information concerning the cause of the problem and it should require as little user intervention as possible. Treating it like a bus error as currently done in Socket-CAN is a bit to strong in my mind.
Quoted 1 line
Can the Controller be assumed to be 'slightly dead', or what? Is there any chance that the bus heals by itself (=> no more bus errors) and can be used in a normal way? Or is a user interaction recommended or _required_?
Yes, if you plug the cable, the bus errors might go away and the TX done interrupt will arrive or you get a bus-off (I have seen both).
Quoted 1 line
Indeed the slow down of bus errors is a reasonable approach, but your suggested method leaves too many questions open for the user :-/
Quoted 9 lines
What questions?
Quoted 5 lines
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop over the application:
After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
Quoted 6 lines
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.
I understand, BEI interrupts get (re-)enabled in recvmsg() if the socket wants to receive bus errors. There can me multiple readers, but that's not a problem. Just some overhead in this function. This would also simplify the implementation as my previous one with "on-demand" bus error would be obsolete. I start to like this solution.
Quoted 7 lines
Well, and if there is no thread listening on bus errors, but we want stats to be updated once in a while, a slow low-prio timer to re-enable BEI might still be created in the stack like Oliver suggested. For Xenomai, you could consider pending an
rtdm_nrtsigto keep the impact on the RT domain low. But that's a minor implementation detail. The important point is to avoid uncontrolled error bursts, even over a short period (20 bus errors at 1 MBit/s already last for > 1 ms).
I think the above solution is enough. Let's go for it?
Wolfgang.
A message that is not in the archive (sent off-list or not yet received): [email protected]
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 12 lines · Oliver Hartkopp
Additionally to the written stuff below (please read that first), i want to remark:
- Remember that we are talking about a case that is not a standard operation mode but a (temporary) error condition that normally leads to a bus-off state and appears only in development and hardware setup phase!
- i would suggest to use some low resolution timestamp (like jiffies) for this, which is very cheap in CPU usage
- the throttling should be configured as a driver module parameter (e.g. bei_thr=0 or bei_thr=200 )due to the need of the global use-case. If you are writing a CAN analysis tool you might want to set bei_thr=0 in other cases a default of 200ms might be the right thing.
We are falling back to #1, i.e. where we are now already. Your suggestion doesn't help us to provide a generic RT-stack for Xenomai.
Quoted 60 lines
Regards,
OliverQuoted 53 lines · Oliver Hartkopp
Quoted 41 lines · Wolfgang Grandegger
Quoted 33 lines · Jan Kiszka
Quoted 12 lines · Wolfgang Grandegger
Quoted 10 lines · Oliver Hartkopp
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Quoted 9 lines
Quoted 4 lines
Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop
over the application:After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
Quoted 6 lines
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.Quoted 5 lines
I understand, BEI interrupts get (re-)enabled in
recvmsg()if the socket wants to receive bus errors. There can me multiple readers, but that's not a problem. Just some overhead in this function. This would also simplify the implementation as my previous one with "on-demand" bus error would be obsolete. I start to like this solution.Hm - to reenable the BEI on user interaction would be a nice thing BUT i can see several problems:
1. In socketcan you have receive queues into the userspace with a length >1
Can you explain to me what the problem behind this is? I don't see it yet.
Quoted 4 lines
Quoted 4 lines
2. How can we handle multiple subscribers (A reads three error frames and reenables therefore the BEI, B reads nothing in this time). Please
remember: To have multiple applications it a vital idea from socketcan.
Same here, I don't see the issue. A and B will both find the first error frame in their queues/ring buffers/whatever. If A has higher priority (or gets an earlier timeslice), it may already re-enable BEI before B was able to run as well. But that's an application-specific scheduling issue and not a problem of the CAN stack (often it is precisely what you want when assigning priorities...).
Quoted 2 lines
Quoted 2 lines
3. The count of occured BEIs gets lost (maybe this is unimportant)
Agreed, but I also don't consider this problematic.
Quoted 6 lines
Quoted 6 lines
----
Regarding (2) the solution could be not to reenable the BEI for a device until every subscriber has read his error frame. But this collides with a raw-socket that's bound to 'any' device (ifindex = 0).
That can cause prio-inversion: a low-prio BEI-reader decides about when a high-prio one gets the next message. No-go for RT.
Quoted 30 lines
Quoted 30 lines
Regarding (3) we could count the BEIs (which would not reduce the interrupt load) or we just stop the BEI after the first occurance which might possibly not enough for some people to implement the CAN academical correct.
As you may see here a tight coupling of the problems on the CAN bus with the application(s!) is very tricky or even impossible in socketcan. Regarding other network devices (like ethernet devices) the notification about Layer 1/2 problems is unusual. The concept of creating error frames was a good compromise for this reason.
As i also would like to avoid to create a timer for "bus error throttling", i got a new idea:
- on the first BEI: create an error frame, set a counter to zero and save the current timestamp
- on the next BEI:
- increment the counter
- check if the time is up for the next error frame (e.g. after 200ms -
configurable?)
- if so: Send the next error frame (including the number of occured
error frames in this 200ms)BEI means ONLY to have a BEI (and no other error).
Of course this does NOT reduce the interrupt load but all this throttling is performed inside the interrupt context. This should not be that problem, or is it? And we do not need a timer ...
Quoted 5 lines
Quoted 5 lines
Any comments to this idea?
Regards,
Oliver
Well, I may oversee some pitfalls of my suggestion, so please help me to understand your concerns.
Jan
Quoted 129 lines · Jan Kiszka
Quoted 12 lines · Oliver Hartkopp
Additionally to the written stuff below (please read that first), i want to remark:
- Remember that we are talking about a case that is not a standard operation mode but a (temporary) error condition that normally leads to a bus-off state and appears only in development and hardware setup phase!
- i would suggest to use some low resolution timestamp (like jiffies) for this, which is very cheap in CPU usage
- the throttling should be configured as a driver module parameter (e.g. bei_thr=0 or bei_thr=200 )due to the need of the global use-case. If you are writing a CAN analysis tool you might want to set bei_thr=0 in other cases a default of 200ms might be the right thing.We are falling back to #1, i.e. where we are now already. Your suggestion doesn't help us to provide a generic RT-stack for Xenomai.
Quoted 5 lines
Regards,
OliverQuoted 51 lines
Quoted 50 lines · Oliver Hartkopp
Quoted 39 lines · Wolfgang Grandegger
Quoted 32 lines · Jan Kiszka
Quoted 12 lines · Wolfgang Grandegger
Quoted 10 lines · Oliver Hartkopp
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Quoted 9 lines
Quoted 4 lines
Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop
over the application:After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
Quoted 6 lines
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.Quoted 5 lines
I understand, BEI interrupts get (re-)enabled in
recvmsg()if the socket wants to receive bus errors. There can me multiple readers, but that's not a problem. Just some overhead in this function. This would also simplify the implementation as my previous one with "on-demand" bus error would be obsolete. I start to like this solution.Hm - to reenable the BEI on user interaction would be a nice thing BUT i can see several problems:
1. In socketcan you have receive queues into the userspace with a length >1
Can you explain to me what the problem behind this is? I don't see it yet.
Quoted 3 lines
Quoted 3 lines
2. How can we handle multiple subscribers (A reads three error frames and reenables therefore the BEI, B reads nothing in this time). Please
remember: To have multiple applications it a vital idea from socketcan.Same here, I don't see the issue. A and B will both find the first error frame in their queues/ring buffers/whatever. If A has higher priority (or gets an earlier timeslice), it may already re-enable BEI before B was able to run as well. But that's an application-specific scheduling issue and not a problem of the CAN stack (often it is precisely what you want when assigning priorities...).
Quoted 1 line
Quoted 1 line
3. The count of occured BEIs gets lost (maybe this is unimportant)
Agreed, but I also don't consider this problematic.
Quoted 5 lines
Quoted 5 lines
----
Regarding (2) the solution could be not to reenable the BEI for a device until every subscriber has read his error frame. But this collides with a raw-socket that's bound to 'any' device (ifindex = 0).
That can cause prio-inversion: a low-prio BEI-reader decides about when a high-prio one gets the next message. No-go for RT.
Quoted 29 lines
Quoted 29 lines
Regarding (3) we could count the BEIs (which would not reduce the interrupt load) or we just stop the BEI after the first occurance which might possibly not enough for some people to implement the CAN academical correct.
As you may see here a tight coupling of the problems on the CAN bus with the application(s!) is very tricky or even impossible in socketcan. Regarding other network devices (like ethernet devices) the notification about Layer 1/2 problems is unusual. The concept of creating error frames was a good compromise for this reason.
As i also would like to avoid to create a timer for "bus error throttling", i got a new idea:
- on the first BEI: create an error frame, set a counter to zero and save the current timestamp
- on the next BEI:
- increment the counter
- check if the time is up for the next error frame (e.g. after 200ms -
configurable?)
- if so: Send the next error frame (including the number of occured
error frames in this 200ms)BEI means ONLY to have a BEI (and no other error).
Of course this does NOT reduce the interrupt load but all this throttling is performed inside the interrupt context. This should not be that problem, or is it? And we do not need a timer ...
Quoted 8 lines
Quoted 5 lines
Quoted 5 lines
Any comments to this idea?
Regards,
OliverWell, I may oversee some pitfalls of my suggestion, so please help me to understand your concerns.
There might be a problem with re-enabling BEI interrupts because we need
to read the ECC. OK, I'm going to implement the method as well to
check for pitfalls.
Wolfgang.
Quoted 136 lines · Wolfgang Grandegger
Quoted 135 lines · Jan Kiszka
Quoted 12 lines · Oliver Hartkopp
Additionally to the written stuff below (please read that first), i want to remark:
- Remember that we are talking about a case that is not a standard operation mode but a (temporary) error condition that normally leads to a bus-off state and appears only in development and hardware setup phase!
- i would suggest to use some low resolution timestamp (like jiffies) for this, which is very cheap in CPU usage
- the throttling should be configured as a driver module parameter (e.g. bei_thr=0 or bei_thr=200 )due to the need of the global use-case. If you are writing a CAN analysis tool you might want to set bei_thr=0 in other cases a default of 200ms might be the right thing.We are falling back to #1, i.e. where we are now already. Your suggestion doesn't help us to provide a generic RT-stack for Xenomai.
Quoted 5 lines
Regards,
OliverQuoted 51 lines
Quoted 50 lines · Oliver Hartkopp
Quoted 39 lines · Wolfgang Grandegger
Quoted 32 lines · Jan Kiszka
Quoted 12 lines · Wolfgang Grandegger
Quoted 10 lines · Oliver Hartkopp
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Quoted 9 lines
Quoted 4 lines
Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop
over the application:After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
Quoted 6 lines
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.Quoted 5 lines
I understand, BEI interrupts get (re-)enabled in
recvmsg()if the socket wants to receive bus errors. There can me multiple readers, but that's not a problem. Just some overhead in this function. This would also simplify the implementation as my previous one with "on-demand" bus error would be obsolete. I start to like this solution.Hm - to reenable the BEI on user interaction would be a nice thing BUT i can see several problems:
1. In socketcan you have receive queues into the userspace with a length >1
Can you explain to me what the problem behind this is? I don't see it yet.
Quoted 3 lines
Quoted 3 lines
2. How can we handle multiple subscribers (A reads three error frames and reenables therefore the BEI, B reads nothing in this time). Please
remember: To have multiple applications it a vital idea from socketcan.Same here, I don't see the issue. A and B will both find the first error frame in their queues/ring buffers/whatever. If A has higher priority (or gets an earlier timeslice), it may already re-enable BEI before B was able to run as well. But that's an application-specific scheduling issue and not a problem of the CAN stack (often it is precisely what you want when assigning priorities...).
Quoted 1 line
Quoted 1 line
3. The count of occured BEIs gets lost (maybe this is unimportant)
Agreed, but I also don't consider this problematic.
Quoted 5 lines
Quoted 5 lines
----
Regarding (2) the solution could be not to reenable the BEI for a device until every subscriber has read his error frame. But this collides with a raw-socket that's bound to 'any' device (ifindex = 0).
That can cause prio-inversion: a low-prio BEI-reader decides about when a high-prio one gets the next message. No-go for RT.
Quoted 34 lines
Quoted 34 lines
Regarding (3) we could count the BEIs (which would not reduce the interrupt load) or we just stop the BEI after the first occurance which might possibly not enough for some people to implement the CAN academical correct.
As you may see here a tight coupling of the problems on the CAN bus with the application(s!) is very tricky or even impossible in socketcan. Regarding other network devices (like ethernet devices) the notification about Layer 1/2 problems is unusual. The concept of creating error frames was a good compromise for this reason.
As i also would like to avoid to create a timer for "bus error throttling", i got a new idea:
- on the first BEI: create an error frame, set a counter to zero and save the current timestamp
- on the next BEI:
- increment the counter
- check if the time is up for the next error frame (e.g. after 200ms -
configurable?)
- if so: Send the next error frame (including the number of occured
error frames in this 200ms)BEI means ONLY to have a BEI (and no other error).
Of course this does NOT reduce the interrupt load but all this throttling is performed inside the interrupt context. This should not be that problem, or is it? And we do not need a timer ...
Any comments to this idea?
Regards,
Oliver
Quoted 6 lines
Quoted 2 lines
Well, I may oversee some pitfalls of my suggestion, so please help me to understand your concerns.
There might be a problem with re-enabling BEI interrupts because we need
to read the ECC. OK, I'm going to implement the method as well to check
for pitfalls.
Attached is the patch and it works fine. The key function rtcan_sja_enable_bus_err() is called from sendmsg():
void rtcan_sja_enable_bus_err(struct rtcan_device *dev)
{
struct rtcan_sja1000 *chip = (struct rtcan_sja1000 *)dev->priv;
if (chip->bus_err_on < 2) {
if (chip->bus_err_on < 1)
chip->read_reg(dev, SJA_ECC);
chip->bus_err_on = 2;
}
}And I do also do not see a real problem with multiple readers. I would commit this solution. I'm just unsure if we should select it silently or if the user should have the choice.
Wolfgang.
drivers/can/Kconfig +13 -0
@@ -49,6 +49,19 @@ config XENO_DRIVERS_CAN_MAX_RECEIVERS The driver maintains a receive filter list per device for fast access. +config XENO_DRIVERS_CAN_BUS_ERR + depends on XENO_DRIVERS_CAN + bool + default n + help + + To avoid unnecessary bus error interrupt flooding, this option enables + bus error interrupts when an application is calling a receive function + on a socket listening on bus errors. After one bus error has occured, + the interrupt will be disabled to allow the application time for error + processing. This option is automatically selected for CAN controllers + supporting bus error interrupts like the SJA1000. + config XENO_DRIVERS_CAN_VIRT depends on XENO_DRIVERS_CAN tristate "Virtual CAN bus driver"
drivers/can/rtcan_dev.h +1 -0
@@ -118,6 +118,7 @@ struct rtcan_device {int (*do_set_bit_time)(struct rtcan_device *dev,struct can_bittime *bit_time,rtdm_lockctx_t *lock_ctx); +void (*do_enable_bus_err)(struct rtcan_device *dev);/* Reception list head. This list contains all filters which have been * registered via a bind call. */
drivers/can/rtcan_raw_dev.c +30 -0
@@ -312,3 +312,33 @@ int rtcan_raw_ioctl_dev(struct rtdm_dev_return ret; } + +#ifdef CONFIG_XENO_DRIVERS_CAN_BUS_ERR +void __rtcan_raw_enable_bus_err (struct rtcan_socket *sock) +{ +int i, begin, end; +struct rtcan_device *dev; +rtdm_lockctx_t lock_ctx; +int ifindex =atomic_read (&sock->ifindex); + +if (ifindex) { + begin = ifindex; + end = ifindex; + }else { + begin =1 ; + end =RTCAN_MAX_DEVICES ; + } + +for (i = begin; i <= end; i++) { +if ((dev =rtcan_dev_get_by_index (i)) ==NULL ) +continue ; + +if (dev->do_enable_bus_err) { +rtdm_lock_get_irqsave (&dev->device_lock, lock_ctx); + dev->do_enable_bus_err (dev); +rtdm_lock_put_irqrestore (&dev->device_lock, lock_ctx); + } +rtcan_dev_dereference (dev); + } +} +#endif /* CONFIG_XENO_DRIVERS_CAN_BUS_ERR*/
drivers/can/rtcan_raw.c +1 -0
@@ -624,6 +624,7 @@ ssize_t rtcan_raw_recvmsg(struct rtdm_dereturn -EINVAL ; } +rtcan_raw_enable_bus_err (sock);/* Set RX timeout */ timeout = (flags &MSG_DONTWAIT ) ?RTDM_TIMEOUT_NONE : sock->rx_timeout;
drivers/can/rtcan_raw.h +11 -0
@@ -41,6 +41,17 @@ void rtcan_loopback(struct rtcan_device#define rtcan_loopback_pending (dev) (0)#endif /* CONFIG_XENO_DRIVERS_CAN_LOOPBACK */ +#ifdef CONFIG_XENO_DRIVERS_CAN_BUS_ERR +void __rtcan_raw_enable_bus_err (struct rtcan_socket *sock); +static inline void rtcan_raw_enable_bus_err (struct rtcan_socket *sock) +{ +if ((sock->err_mask &CAN_ERR_BUSERROR )) +__rtcan_raw_enable_bus_err (sock); +} +#else +#define rtcan_raw_enable_bus_err (sock) +#endif +int __init rtcan_raw_proto_register (void ); void __exit rtcan_raw_proto_unregister(void);
drivers/can/sja1000/Kconfig +1 -0
@@ -1,6 +1,7 @@ config XENO_DRIVERS_CAN_SJA1000 depends on XENO_DRIVERS_CAN tristate "Philips SJA1000 CAN controller" + select XENO_DRIVERS_CAN_BUS_ERR config XENO_DRIVERS_CAN_SJA1000_ISA depends on XENO_DRIVERS_CAN_SJA1000
drivers/can/sja1000/rtcan_sja1000.c +23 -10
@@ -293,18 +293,21 @@ static int rtcan_sja_interrupt(rtdm_irq_ dev->state = dev->state_before_sleep;/* Error Interrupt? */ -if (irq_source & (SJA_IR_EI |SJA_IR_DOI |SJA_IR_EPI | +if (irq_source & (SJA_IR_EI |SJA_IR_DOI |SJA_IR_EPI |SJA_IR_ALI |SJA_IR_BEI )) { +/* Check error condition and fill error frame */ -rtcan_sja_err_interrupt (dev, chip, &skb, irq_source); +if (!((irq_source &SJA_IR_BEI ) && (chip->bus_err_on-- <2 ))) { +rtcan_sja_err_interrupt (dev, chip, &skb, irq_source); -if (recv_lock_free) { - recv_lock_free =0 ; -rtdm_lock_get (&rtcan_recv_list_lock); -rtdm_lock_get (&rtcan_socket_lock); +if (recv_lock_free) { + recv_lock_free =0 ; +rtdm_lock_get (&rtcan_recv_list_lock); +rtdm_lock_get (&rtcan_socket_lock); + } +/* Pass error frame out to the sockets */ +rtcan_rcv (dev, &skb); } -/* Pass error frame out to the sockets */ -rtcan_rcv (dev, &skb); }/* Transmit Interrupt? */
@@ -625,8 +628,16 @@ int rtcan_sja_set_bit_time(struct rtcan_return 0 ; } +void rtcan_sja_enable_bus_err (struct rtcan_device *dev) +{ +struct rtcan_sja1000 *chip = (struct rtcan_sja1000 *)dev->priv; - +if (chip->bus_err_on <2 ) { +if (chip->bus_err_on <1 ) + chip->read_reg (dev,SJA_ECC ); + chip->bus_err_on =2 ; + } +}/* * Start a transmission to a SJA1000 device
@@ -745,8 +756,10 @@ int rtcan_sja1000_register(struct rtcan_ dev->do_set_mode = rtcan_sja_set_mode; dev->do_get_state = rtcan_sja_get_state; dev->do_set_bit_time = rtcan_sja_set_bit_time; + dev->do_enable_bus_err = rtcan_sja_enable_bus_err; + chip->bus_err_on =1 ; - ret =rtdm_irq_request (&dev->irq_handle, + ret =rtdm_irq_request (&dev->irq_handle, chip->irq_num, rtcan_sja_interrupt, chip->irq_flags, sja_ctrl_name, dev);if (ret) {
drivers/can/sja1000/Config.in +4 -0
@@ -4,6 +4,10 @@ dep_tristate 'Philips SJA1000 CAN controller' CONFIG_XENO_DRIVERS_CAN_SJA1000 $CONFIG_XENO_DRIVERS_CAN +if [ "$CONFIG_XENO_DRIVERS_CAN_SJA1000" != "n" ]; then + define_bool CONFIG_XENO_DRIVERS_CAN_BUS_ERR y +fi + dep_tristate ' Standard ISA controllers' CONFIG_XENO_DRIVERS_CAN_SJA1000_ISA $CONFIG_XENO_DRIVERS_CAN_SJA1000 if [ "$CONFIG_XENO_DRIVERS_CAN_SJA1000_ISA" != "n" ]; then int ' Maximum number of controllers' CONFIG_XENO_DRIVERS_CAN_SJA1000_ISA_MAX_DEV 4
drivers/can/sja1000/rtcan_sja1000.h +1 -0
@@ -30,6 +30,7 @@ struct rtcan_sja1000 {unsigned short irq_flags;unsigned char ocr;unsigned char cdr; +char bus_err_on; };int rtcan_sja_create_proc (struct rtcan_device * dev);
Quoted 15 lines · Wolfgang Grandegger
...
Attached is the patch and it works fine. The key functionrtcan_sja_enable_bus_err()is called fromsendmsg():void
rtcan_sja_enable_bus_err(struct rtcan_device *dev){ struct rtcan_sja1000 *chip = (struct rtcan_sja1000 *)dev->priv; if (chip->bus_err_on < 2) { if (chip->bus_err_on < 1) chip->read_reg(dev, SJA_ECC); chip->bus_err_on = 2; } }
Quoted 3 lines
And I do also do not see a real problem with multiple readers. I would commit this solution. I'm just unsure if we should select it silently or if the user should have the choice.
I would say no to user-selectability unless someone comes up with a serious downside of this approach.
Are there any other error interrupt sources we should treat the same way? Or all? Just to make the behaviour as regular as reasonable. I have no opinion yet, I only want to make sure we have considered this as well before we set the change API in stone.
Nice work!
Jan
Hello,
Quoted 23 lines · Jan Kiszka
Quoted 15 lines · Wolfgang Grandegger
...
Attached is the patch and it works fine. The key functionrtcan_sja_enable_bus_err()is called fromsendmsg():void
rtcan_sja_enable_bus_err(struct rtcan_device *dev){ struct rtcan_sja1000 *chip = (struct rtcan_sja1000 *)dev->priv; if (chip->bus_err_on < 2) { if (chip->bus_err_on < 1) chip->read_reg(dev, SJA_ECC); chip->bus_err_on = 2; } }Quoted 3 lines
And I do also do not see a real problem with multiple readers. I would commit this solution. I'm just unsure if we should select it silently or if the user should have the choice.
I would say no to user-selectability unless someone comes up with a serious downside of this approach.
Quoted 6 lines
Are there any other error interrupt sources we should treat the same way? Or all? Just to make the behaviour as regular as reasonable. I have no opinion yet, I only want to make sure we have considered this as well before we set the change API in stone.
Nice work!
OK, I have just commited the following changes:
2007-04-02 Wolfgang Grandegger <[email protected]>
* ksrc/drivers/can/*: The option CONFIG_XENO_DRIVERS_CAN_BUS_ERR now enables bus error interrupts when an application is calling a receive function on a socket listening on bus errors. After one bus error has occured, the interrupt will be disabled to allow the application time for error processing and to efficiently avoid bus error interrupt flooding. This option is automatically selected for CAN controllers supporting bus error interrupts like the SJA1000.
* include/rtdm/rtcan.h: Add some doc on bus-off and bus-error error conditions and the restart policy.
* src/utils/can/rtcanconfig.c: Controller mode settings and doc has been corrected.
Wolfgang.
Quoted 11 lines · Wolfgang Grandegger
OK, I have just commited the following changes:
2007-04-02 Wolfgang Grandegger <[email protected]>
* ksrc/drivers/can/*: The option
CONFIG_XENO_DRIVERS_CAN_BUS_ERRnow enables bus error interrupts when an application is calling a receive function on a socket listening on bus errors. After one bus error has occured, the interrupt will be disabled to allow the application time for error processing and to efficiently avoid bus error interrupt flooding. This option is automatically selected for CAN controllers supporting bus error interrupts like the SJA1000.
Just one final nitpicking question: Who's to read the help text of CONFIG_XENO_DRIVERS_CAN_BUS_ERR - except people reading Kconfig directly? (My point is that this explanation may rather become a code comment.)
Jan
Quoted 13 lines · Jan Kiszka
Quoted 11 lines · Wolfgang Grandegger
OK, I have just commited the following changes:
2007-04-02 Wolfgang Grandegger <[email protected]>
* ksrc/drivers/can/*: The option
CONFIG_XENO_DRIVERS_CAN_BUS_ERRnow enables bus error interrupts when an application is calling a receive function on a socket listening on bus errors. After one bus error has occured, the interrupt will be disabled to allow the application time for error processing and to efficiently avoid bus error interrupt flooding. This option is automatically selected for CAN controllers supporting bus error interrupts like the SJA1000.
Quoted 4 lines
Just one final nitpicking question: Who's to read the help text of
CONFIG_XENO_DRIVERS_CAN_BUS_ERR- except people readingKconfigdirectly? (My point is that this explanation may rather become a code comment.)
Good hint. Patch comes soon. At least it's already documented in the API doc.
Wolfgang.
Quoted 29 lines · Oliver Hartkopp
Quoted 28 lines · Wolfgang Grandegger
Quoted 26 lines · Jan Kiszka
Quoted 9 lines · Wolfgang Grandegger
Quoted 5 lines · Oliver Hartkopp
I would tend to reduce the notifications to the user by creating a timer at the first bus error interrupt. The first BE irq would lead to a
CAN_ERR_BUSERRORand after a (configurable) time (e.g.250ms) the next information about bus errors is allowed to be passed to the user. After this time period is over a newCAN_ERR_BUSERRORmay be passed to the user containing the count of occurred bus errors somewhere in the data[]-section of the Error Frame. When a normal RX/TX-interrupt indicates a 'working' CAN again, the timer would be terminated.Instead of a fix configurable time we could also think about a dynamic behaviour (e.g. with increasing periods).
What do you think about this?
The question is if one bus-error does provide enough information on the cause of the electrical problem or if a sequence is better. Furthermore, I personally regard the use of timers as to heavy. But the solution is feasible, of course. Any other opinions?
I think Oliver's suggestions points in the right direction. But instead of only coding a timer into the stack, I still vote for closing the loop over the application:
After the first error in a potential series, the related error frame is queued, listeners are woken up, and BEI is disabled for now. Once some listener read the error frame *and* decided to call into the stack for further bus errors, BEI is enabled again.
That way the application decides about the error-related IRQ rate and can easily throttle it by delaying the next receive call. Moreover, threads of higher priority will be delayed at worst by one error IRQ. This mechanism just needs some words in the documentation ("Be warned:
error frames may overwhelm you. Throttle your reception!"), but no further user-visible config options.
Quoted 6 lines
Quoted 1 line
I understand, BEI interrupts get (re-)enabled in
recvmsg()if the socket wants to receive bus errors. There can me multiple readers, but that's not a problem. Just some overhead in this function. This would also simplify the implementation as my previous one with "on-demand" bus error would be obsolete. I start to like this solution.Hm - to reenable the BEI on user interaction would be a nice thing BUT i can see several problems:
1. In socketcan you have receive queues into the userspace with a length >1
Yes, and they are still used to receive normal and other error messages.
Quoted 3 lines
2. How can we handle multiple subscribers (A reads three error frames and reenables therefore the BEI, B reads nothing in this time). Please
remember: To have multiple applications it a vital idea from socketcan.
My idea was to re-enable (or trigger) one BEI at the beginning of recvmsg in selected. Then all listening sockets will receive all bus error messages, e.g. A and B will receive up to the sum of the recvmsg calls form A and B. Well, this mixture is not really nice but it will downscale the bus error rate to a "digestible" level.
Quoted 1 line
3. The count of occured BEIs gets lost (maybe this is unimportant)
I do not regard this as a problem. The purpose of this option is to downscale the BEI rate.
Quoted 5 lines
----
Regarding (2) the solution could be not to reenable the BEI for a device until every subscriber has read his error frame. But this collides with a raw-socket that's bound to 'any' device (ifindex = 0).
We cannot do that.
Quoted 23 lines
Regarding (3) we could count the BEIs (which would not reduce the interrupt load) or we just stop the BEI after the first occurance which might possibly not enough for some people to implement the CAN academical correct.
As you may see here a tight coupling of the problems on the CAN bus with the application(s!) is very tricky or even impossible in socketcan. Regarding other network devices (like ethernet devices) the notification about Layer 1/2 problems is unusual. The concept of creating error frames was a good compromise for this reason.
As i also would like to avoid to create a timer for "bus error throttling", i got a new idea:
- on the first BEI: create an error frame, set a counter to zero and save the current timestamp
- on the next BEI:
- increment the counter
- check if the time is up for the next error frame (e.g. after 200ms -
configurable?)
- if so: Send the next error frame (including the number of occured
error frames in this 200ms)
Quoted 5 lines
BEI means ONLY to have a BEI (and no other error).
Of course this does NOT reduce the interrupt load but all this throttling is performed inside the interrupt context. This should not be that problem, or is it? And we do not need a timer ...
It's about reducing the very high BEI interrupt rate. A rate of 15kHz is _really_ heavy on mid and low end systems and especially for real-time.
Quoted 1 line
Any comments to this idea?
Well, till now I do not see a 100% satisfactory solution and I do not want to make the implementation too sophisticated. Currently I'm in favor of my proposes solution with a low default value (10 or even 1):
config XENO_DRIVERS_CAN_SJA1000_BUS_ERR_LIMIT
depends on XENO_DRIVERS_CAN_SJA1000 int "Maximum number of successive bus errors" range 0 255
default 10
help
CAN bus errors are very useful for analyzing electrical problems but they can come at a very high rate resulting in interrupt flooding with bad impact on system performance and real-time behavior. This option, if greater than 0, will limit the amount of successive bus error interrupts. If the limit is reached, an error message with "can_id = CAN_ERR_BUSERR_FLOOD" is sent and the bus error interrutps get disabled. They get re-enabled on restart of the device and on any successful message transmission or reception. Be aware that bus error interrupts are only enabled if at least one socket is listening on bus errors.
The user has still all choices. What is you preferred solution?
Wolfgang