e1000: Detected Tx Unit Hang
Subsystems (2)
Hello,
I can't login to one of our servers and just got this in an ipmi sol session:
[18169.209181] e1000: eth0: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.209183] Tx Queue <0> [18169.209184] TDH <e3> [18169.209185] TDT <e3> [18169.209186] next_to_use <e3> [18169.209187] next_to_clean <bd> [18169.209188] buffer_info[next_to_clean] [18169.209189] time_stamp <10043e4d2> [18169.209190] next_to_watch <be> [18169.209191] jiffies <10043e6f6> [18169.209192] next_to_watch.status <1> [18169.256978] e1000: eth2: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.256979] Tx Queue <0> [18169.256980] TDH <de> [18169.256982] TDT <de> [18169.256983] next_to_use <de> [18169.256984] next_to_clean <bc> [18169.256985] buffer_info[next_to_clean] [18169.256986] time_stamp <10043e511> [18169.256987] next_to_watch <bd> [18169.256988] jiffies <10043e701> [18169.256989] next_to_watch.status <1>
This is with 2.6.22.18. Is there any chance to recover the system? For some reasons I would prefer not to reboot now.
Thanks,
Bernd
Quoted 28 lines · Bernd Schubert
Hello,
I can't login to one of our servers and just got this in an ipmi sol session:
[18169.209181] e1000: eth0: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.209183] Tx Queue <0> [18169.209184] TDH <e3> [18169.209185] TDT <e3> [18169.209186] next_to_use <e3> [18169.209187] next_to_clean <bd> [18169.209188] buffer_info[next_to_clean] [18169.209189] time_stamp <10043e4d2> [18169.209190] next_to_watch <be> [18169.209191] jiffies <10043e6f6> [18169.209192] next_to_watch.status <1> [18169.256978] e1000: eth2: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.256979] Tx Queue <0> [18169.256980] TDH <de> [18169.256982] TDT <de> [18169.256983] next_to_use <de> [18169.256984] next_to_clean <bc> [18169.256985] buffer_info[next_to_clean] [18169.256986] time_stamp <10043e511> [18169.256987] next_to_watch <bd> [18169.256988] jiffies <10043e701> [18169.256989] next_to_watch.status <1>
Quoted 2 lines
This is with 2.6.22.18. Is there any chance to recover the system? For some reasons I would prefer not to reboot now.
if that's all you have then it was false alarm. there should be a 'netdev timeout
- link reset' following those messages. can you send some more context on those messages?
in real tx hang cases, the hardware is reset within 2 seconds, and everything continues as normal.
Auke
Quoted 29 lines · Auke
Quoted 28 lines · Bernd Schubert
Hello,
I can't login to one of our servers and just got this in an ipmi sol session:
[18169.209181] e1000: eth0: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.209183] Tx Queue <0> [18169.209184] TDH <e3> [18169.209185] TDT <e3> [18169.209186] next_to_use <e3> [18169.209187] next_to_clean <bd> [18169.209188] buffer_info[next_to_clean] [18169.209189] time_stamp <10043e4d2> [18169.209190] next_to_watch <be> [18169.209191] jiffies <10043e6f6> [18169.209192] next_to_watch.status <1> [18169.256978] e1000: eth2: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.256979] Tx Queue <0> [18169.256980] TDH <de> [18169.256982] TDT <de> [18169.256983] next_to_use <de> [18169.256984] next_to_clean <bc> [18169.256985] buffer_info[next_to_clean] [18169.256986] time_stamp <10043e511> [18169.256987] next_to_watch <bd> [18169.256988] jiffies <10043e701> [18169.256989] next_to_watch.status <1>
Quoted 6 lines
Quoted 2 lines
This is with 2.6.22.18. Is there any chance to recover the system? For some reasons I would prefer not to reboot now.
if that's all you have then it was false alarm. there should be a 'netdev timeout - link reset' following those messages. can you send some more context on those messages?
All I presently know is that there are 20 servers and login doesn't work any more - sysrq+t does show me it hangs in fuse, which is accessing the underlying nfs (we are using unionfs-fuse). While I checked the sysrq-t output suddenly these e1000 messages appeared.
Thinking a bit about it, it either could be 2.6.22.18 has an e1000 bug, which 2.6.22.X didn't have (X=16, I think, but I'm not sure) or someone mis-configured the switch/network environment today.
Hmm, now that I think about the last part, there already had been other networking problems today, which were supposed to be fixed several hours ago. Seems they didn't fix it properly.
Quoted 3 lines
in real tx hang cases, the hardware is reset within 2 seconds, and everything continues as normal.
Thanks, this gives me hope I don't need to reboot the serves (reboot would mean I would need to start 60 md-raid rebuilds...).
Thanks,
Bernd
Quoted 47 lines · Bernd Schubert
Quoted 29 lines · Auke
Quoted 28 lines · Bernd Schubert
Hello,
I can't login to one of our servers and just got this in an ipmi sol session:
[18169.209181] e1000: eth0: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.209183] Tx Queue <0> [18169.209184] TDH <e3> [18169.209185] TDT <e3> [18169.209186] next_to_use <e3> [18169.209187] next_to_clean <bd> [18169.209188] buffer_info[next_to_clean] [18169.209189] time_stamp <10043e4d2> [18169.209190] next_to_watch <be> [18169.209191] jiffies <10043e6f6> [18169.209192] next_to_watch.status <1> [18169.256978] e1000: eth2: e1000_clean_tx_irq: Detected Tx Unit Hang [18169.256979] Tx Queue <0> [18169.256980] TDH <de> [18169.256982] TDT <de> [18169.256983] next_to_use <de> [18169.256984] next_to_clean <bc> [18169.256985] buffer_info[next_to_clean] [18169.256986] time_stamp <10043e511> [18169.256987] next_to_watch <bd> [18169.256988] jiffies <10043e701> [18169.256989] next_to_watch.status <1>Quoted 5 lines
Quoted 2 lines
This is with 2.6.22.18. Is there any chance to recover the system? For some reasons I would prefer not to reboot now.
if that's all you have then it was false alarm. there should be a 'netdev timeout - link reset' following those messages. can you send some more context on those messages?
All I presently know is that there are 20 servers and login doesn't work any more - sysrq+t does show me it hangs in fuse, which is accessing the underlying nfs (we are using unionfs-fuse). While I checked the sysrq-t output suddenly these e1000 messages appeared.
Thinking a bit about it, it either could be 2.6.22.18 has an e1000 bug, which 2.6.22.X didn't have (X=16, I think, but I'm not sure) or someone mis-configured the switch/network environment today.
Hmm, now that I think about the last part, there already had been other networking problems today, which were supposed to be fixed several hours ago. Seems they didn't fix it properly.
Quoted 5 lines
Quoted 2 lines
in real tx hang cases, the hardware is reset within 2 seconds, and everything continues as normal.
Thanks, this gives me hope I don't need to reboot the serves (reboot would mean I would need to start 60 md-raid rebuilds...).
my first thought after I read this e-mail is that the tx-hang message is just a symptom of your system not responding or being spinlocked all the time. These TX hang issues normally completely do not interfere with normal system operation and unless you have continuous TX resets you would be able to logon perfectly fine.
I think you might have hit another kernel bug here... perhaps even unionfs/fuse related and that certainly looks plausible from your problem description.
looking at the changelog for 2.6.22.16->2.6.22.18 I can't see anything relevant (see
http://git.kernel.org/?p=linux/kernel/git/stable/linux-2.6.22.y.git;a=shortlog),
but there are definately no e1000 driver changes in that range anyway.
I don't suppose you can do a git-bisect? that would certainly help. I don't think we can rule out anything just yet here.
At least try to revert some of your systems to the previous kernel version and see if the problem goes away...