AK4114 - capturing spdif input stops the stream
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in ak4114.c:
res = external_rate(rcs1);
if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) {
snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags);
if (snd_pcm_running(ak4114->capture_substream)) {
printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res);
snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING);
res = 1;
}
snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags);
}The stream gets stopped because res = 192000 and runtime->rate = 44100.
The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and runtime->rate is 44100 instead of 192000.
Of course recording at 192000 works fine.
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
If the card cannot detect input frequency reliably (the driver developer should know), I guess it should not do the check in ak4114.c at all - I can prepare a simple patch for that.
The same will most probably apply to cards with AK4117 as the code looks the same.
I know it is a minor issue but if a user hits this problem, it will take him a lot of effort to fix his setup appropriately.
Thanks,
Pavel.
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 33 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.
Quoted 6 lines
Of course recording at 192000 works fine.
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
What about to call snd_ak4114_check_rate_and_errors() at PCM open? You can pass AK4114_CHECK_NO_RATE to flags argument to skip the check there, at least.
Takashi
Takashi Iwai napsal(a):
Quoted 36 lines
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 34 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.Of course recording at 192000 works fine.
Quoted 10 lines
Quoted 4 lines
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
What about to call
snd_ak4114_check_rate_and_errors()at PCM open? You can passAK4114_CHECK_NO_RATEto flags argument to skip the check there, at least.
Well, I would not want to skip the check for cards with functioning rate detection. Plus snd_ak4114_check_rate_and_errors gets called periodically afterwards.
It would be great if the driver in slaved-clock mode cut its list of native sample rates to the only one currently fed to SPDIF input and detected by AK4114. A routine doing this would be called when switching clock to the slaved-clock mode and called again in snd_ak4114_check_rate_and_errors() when any change in input rate is detected (and the stream is not running). Going back to master-clock mode would restore the existing list of all the rates.
In case of input sample rate change when the PCM stream is running, the stream would be stopped. This is already implemented in the current version of snd_ak4114_check_rate_and_errors()
Unfortunately, I do not know how to change the rates list properly not to break something. If it is only about changing the HW params struct, that would be trivial.
Thanks for suggestions,
Pavel.
At Thu, 13 Mar 2008 13:49:20 +0100,
Quoted 49 lines · Pavel Hofman
Takashi Iwai napsal(a):
Quoted 36 lines
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 34 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.Of course recording at 192000 works fine.
Quoted 10 lines
Quoted 4 lines
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
What about to call
snd_ak4114_check_rate_and_errors()at PCM open? You can passAK4114_CHECK_NO_RATEto flags argument to skip the check there, at least.
Quoted 3 lines
Well, I would not want to skip the check for cards with functioning rate detection. Plus
snd_ak4114_check_rate_and_errorsgets called periodically afterwards.
Yes, but the check there is simply useless at open. It's only for running states. snd_ak4114_external_rate() would be simler, then.
Quoted 8 lines
It would be great if the driver in slaved-clock mode cut its list of native sample rates to the only one currently fed to SPDIF input and detected by AK4114. A routine doing this would be called when switching clock to the slaved-clock mode and called again in
snd_ak4114_check_rate_and_errors()when any change in input rate is detected (and the stream is not running). Going back to master-clock mode would restore the existing list of all the rates.
Quoted 7 lines
In case of input sample rate change when the PCM stream is running, the stream would be stopped. This is already implemented in the current version of
snd_ak4114_check_rate_and_errors()Unfortunately, I do not know how to change the rates list properly not to break something. If it is only about changing the HW params struct, that would be trivial.
Suppose that the slave <-> master mode change doesn't happen during the stream is opened, it's relatively easy. So far, ice1724.c doesn't call spdif.ops.open/close callbacks. Call them in *_spdif_open/close functions with NULL check. Then add open hook in juli.c so that you can change rates_min and rates_max to the currently detected rate at open...
Well, it's faster to write a patch than texts.
Takashi
pci/ice1712/ice1724.c +8 -0
@@ -970,6 +970,8 @@ static int snd_vt1724_playback_spdif_ope VT1724_BUFFER_ALIGN);snd_pcm_hw_constraint_step (runtime,0 ,SNDRV_PCM_HW_PARAM_BUFFER_BYTES ,VT1724_BUFFER_ALIGN ); +if (ice->spdif.ops.open) + ice->spdif.ops.open (ice, substream);return 0 ; }
@@ -980,6 +982,8 @@ static int snd_vt1724_playback_spdif_cloif (PRO_RATE_RESET )snd_vt1724_set_pro_rate (ice,PRO_RATE_DEFAULT ,0 ); ice->playback_con_substream =NULL ; +if (ice->spdif.ops.close) + ice->spdif.ops.close (ice, substream);return 0 ; }
@@ -1002,6 +1006,8 @@ static int snd_vt1724_capture_spdif_open VT1724_BUFFER_ALIGN);snd_pcm_hw_constraint_step (runtime,0 ,SNDRV_PCM_HW_PARAM_BUFFER_BYTES ,VT1724_BUFFER_ALIGN ); +if (ice->spdif.ops.open) + ice->spdif.ops.open (ice, substream);return 0 ; }
@@ -1012,6 +1018,8 @@ static int snd_vt1724_capture_spdif_closif (PRO_RATE_RESET )snd_vt1724_set_pro_rate (ice,PRO_RATE_DEFAULT ,0 ); ice->capture_con_substream =NULL ; +if (ice->spdif.ops.close) + ice->spdif.ops.close (ice, substream);return 0 ; }
pci/ice1712/juli.c +17 -0
@@ -75,6 +75,22 @@ static unsigned char juli_ak4114_read(vostatic unsigned char juli_ak4114_read (void *private_data,unsigned char reg) {return snd_vt1724_read_i2c ((struct snd_ice1712 *)private_data,AK4114_ADDR , reg); +} + +static void juli_spdif_in_open (struct snd_ice1712 *ice, +struct snd_pcm_substream *substream) +{ +struct juli_spec *spec = ice->spec; +struct snd_pcm_runtime *runtime = substream->runtime; +int rate; + +if (substream->stream ==SNDRV_PCM_STREAM_PLAYBACK ) +return ; + rate =snd_ak4114_external_rate (spec->ak4114); +if (rate >= runtime->hw.rate_min && rate <= runtime->hw.rate_max) { + runtime->hw.rate_min = rate; + runtime->hw.rate_max = rate; + } }/*
@@ -210,6 +226,7 @@ static int __devinit juli_init(struct snreturn err; } + ice->spdif.ops.open = juli_spdif_in_open;return 0 ; }
Takashi Iwai napsal(a):
Quoted 78 lines
At Thu, 13 Mar 2008 13:49:20 +0100,
Quoted 41 lines · Pavel Hofman
Takashi Iwai napsal(a):
Quoted 40 lines
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 38 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.Of course recording at 192000 works fine.
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
Quoted 8 lines
Quoted 5 lines
What about to call
snd_ak4114_check_rate_and_errors()at PCM open? You can passAK4114_CHECK_NO_RATEto flags argument to skip the check there, at least.Well, I would not want to skip the check for cards with functioning rate detection. Plus
snd_ak4114_check_rate_and_errorsgets called periodically afterwards.Yes, but the check there is simply useless at open. It's only for running states.
snd_ak4114_external_rate()would be simler, then.Quoted 8 lines
It would be great if the driver in slaved-clock mode cut its list of native sample rates to the only one currently fed to SPDIF input and detected by AK4114. A routine doing this would be called when switching clock to the slaved-clock mode and called again in
snd_ak4114_check_rate_and_errors()when any change in input rate is detected (and the stream is not running). Going back to master-clock mode would restore the existing list of all the rates.Quoted 7 lines
In case of input sample rate change when the PCM stream is running, the stream would be stopped. This is already implemented in the current version of
snd_ak4114_check_rate_and_errors()Unfortunately, I do not know how to change the rates list properly not to break something. If it is only about changing the HW params struct, that would be trivial.
Suppose that the slave <-> master mode change doesn't happen during the stream is opened, it's relatively easy. So far,
ice1724.cdoesn't call spdif.ops.open/close callbacks. Call them in *_spdif_open/close functions with NULL check. Then add open hook injuli.cso that you can changerates_minandrates_maxto the currently detected rate at open...
Quoted 4 lines
Well, it's faster to write a patch than texts.
Takashi
Thanks a lot. I will test it in the evening. The code looks simple now but without your help I would be stuck forever :)
Pavel.
Quoted 71 lines · Takashi Iwai
At Thu, 13 Mar 2008 13:49:20 +0100,
Quoted 41 lines · Pavel Hofman
Takashi Iwai napsal(a):
Quoted 40 lines
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 38 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.Of course recording at 192000 works fine.
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
Quoted 8 lines
Quoted 5 lines
What about to call
snd_ak4114_check_rate_and_errors()at PCM open? You can passAK4114_CHECK_NO_RATEto flags argument to skip the check there, at least.Well, I would not want to skip the check for cards with functioning rate detection. Plus
snd_ak4114_check_rate_and_errorsgets called periodically afterwards.Yes, but the check there is simply useless at open. It's only for running states.
snd_ak4114_external_rate()would be simler, then.Quoted 8 lines
It would be great if the driver in slaved-clock mode cut its list of native sample rates to the only one currently fed to SPDIF input and detected by AK4114. A routine doing this would be called when switching clock to the slaved-clock mode and called again in
snd_ak4114_check_rate_and_errors()when any change in input rate is detected (and the stream is not running). Going back to master-clock mode would restore the existing list of all the rates.Quoted 7 lines
In case of input sample rate change when the PCM stream is running, the stream would be stopped. This is already implemented in the current version of
snd_ak4114_check_rate_and_errors()Unfortunately, I do not know how to change the rates list properly not to break something. If it is only about changing the HW params struct, that would be trivial.
Quoted 10 lines
Suppose that the slave <-> master mode change doesn't happen during the stream is opened, it's relatively easy. So far,
ice1724.cdoesn't call spdif.ops.open/close callbacks. Call them in *_spdif_open/close functions with NULL check. Then add open hook injuli.cso that you can changerates_minandrates_maxto the currently detected rate at open...Well, it's faster to write a patch than texts.
.......
Takashi, thanks for the patch, it works flawlessly.
Another issue - when the external clock changes rate and the stream is running (typically when starting the source playback which switches the source card (and its SPDIF-OUT) to a different frequency), the target card detects the change and the capture stream is stopped in snd_ak4114_check_rate_and_errors() by
snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING);
How should recording applications behave with stream in this mode? I would expect arecord to close, but it does nothing. Is this correct behaviour?
Thanks,
Pavel.
At Thu, 13 Mar 2008 20:18:34 +0100,
Quoted 80 lines · Pavel Hofman
Quoted 78 lines · Takashi Iwai
At Thu, 13 Mar 2008 13:49:20 +0100,
Quoted 41 lines · Pavel Hofman
Takashi Iwai napsal(a):
Quoted 40 lines
At Wed, 12 Mar 2008 23:50:08 +0100,
Quoted 38 lines · Pavel Hofman
Hi,
here is my scenario:
ICE1724 card, trying to record from SPDIF input via AK4114, ICE1724 slaved to SPDIF clock from the receiver.
The card detects SPDIF input rate correctly (in my case ESI Juli where AK4114 is provided with independent clock signal to enable the rate detection). Let's say it is 192000.
Now I want to arecord the input stream, let's say in CD quality, using the plug plugin. The command fails, because of the check in
ak4114.c:res = external_rate(rcs1); if (!(flags & AK4114_CHECK_NO_RATE) && runtime && runtime->rate != res) { snd_pcm_stream_lock_irqsave(ak4114->capture_substream, _flags); if (snd_pcm_running(ak4114->capture_substream)) { printk(KERN_DEBUG "rate changed (%i <- %i)\n", runtime->rate, res); snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING); res = 1; } snd_pcm_stream_unlock_irqrestore(ak4114->capture_substream, _flags); }The stream gets stopped because res = 192000 and
runtime->rate= 44100.The problem is that the capture device still offers all the available rates, instead of the single SPDIF input one. Thus, the plug plugin is not forced to convert from 192000 to 44100 and
runtime->rateis 44100 instead of 192000.Of course recording at 192000 works fine.
What would be the best way to force the SPDIF capture device to offer (advertise) only the current rate? This functionality would have to be applicable only to the few cards correctly detecting incoming rate (unlike most ice1724 cards without independent clock in slave mode).
Quoted 8 lines
Quoted 5 lines
What about to call
snd_ak4114_check_rate_and_errors()at PCM open? You can passAK4114_CHECK_NO_RATEto flags argument to skip the check there, at least.Well, I would not want to skip the check for cards with functioning rate detection. Plus
snd_ak4114_check_rate_and_errorsgets called periodically afterwards.Yes, but the check there is simply useless at open. It's only for running states.
snd_ak4114_external_rate()would be simler, then.Quoted 8 lines
It would be great if the driver in slaved-clock mode cut its list of native sample rates to the only one currently fed to SPDIF input and detected by AK4114. A routine doing this would be called when switching clock to the slaved-clock mode and called again in
snd_ak4114_check_rate_and_errors()when any change in input rate is detected (and the stream is not running). Going back to master-clock mode would restore the existing list of all the rates.Quoted 7 lines
In case of input sample rate change when the PCM stream is running, the stream would be stopped. This is already implemented in the current version of
snd_ak4114_check_rate_and_errors()Unfortunately, I do not know how to change the rates list properly not to break something. If it is only about changing the HW params struct, that would be trivial.
Suppose that the slave <-> master mode change doesn't happen during the stream is opened, it's relatively easy. So far,
ice1724.cdoesn't call spdif.ops.open/close callbacks. Call them in *_spdif_open/close functions with NULL check. Then add open hook injuli.cso that you can changerates_minandrates_maxto the currently detected rate at open...
Quoted 8 lines
Quoted 3 lines
Well, it's faster to write a patch than texts.
.......
Takashi, thanks for the patch, it works flawlessly.
OK, now committed to HG tree.
Quoted 11 lines
Another issue - when the external clock changes rate and the stream is running (typically when starting the source playback which switches the source card (and its SPDIF-OUT) to a different frequency), the target card detects the change and the capture stream is stopped in
snd_ak4114_check_rate_and_errors()by
snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING);How should recording applications behave with stream in this mode? I would expect arecord to close, but it does nothing. Is this correct behaviour?
It's supposed to be drained then stopped. Maybe something wrong in the handling of DRAINING state in the capture direction.
Anyway, it's a bit strange situation as is. Since the sample rate is changed, you can't call simply prepare again like normal errors...
Takashi
Quoted 3 lines · Takashi Iwai
Quoted 1 line
Takashi, thanks for the patch, it works flawlessly.
OK, now committed to HG tree.
Thanks a lot. I will just resolve the conflicts now :)
Quoted 12 lines
Quoted 11 lines
Another issue - when the external clock changes rate and the stream is running (typically when starting the source playback which switches the source card (and its SPDIF-OUT) to a different frequency), the target card detects the change and the capture stream is stopped in
snd_ak4114_check_rate_and_errors()by
snd_pcm_stop(ak4114->capture_substream, SNDRV_PCM_STATE_DRAINING);How should recording applications behave with stream in this mode? I would expect arecord to close, but it does nothing. Is this correct behaviour?
Quoted 5 lines
It's supposed to be drained then stopped. Maybe something wrong in the handling of DRAINING state in the capture direction.
Anyway, it's a bit strange situation as is. Since the sample rate is changed, you can't call simply prepare again like normal errors...
I would expect arecord to quit with some relevant message. In larger recording apps, e.g. Audacity, it should probably stop recording and display a warning message. No idea if the controlled stop with an appropriate error message is feasible with the existing API and code.
Thanks,
Pavel Hofman.