Quoted 4 lines · Avi Kivity

This is the second release of network drivers for Windows guests running on a kvm host. The drivers are intended for Windows 2000 and Windows XP, and Windows 2003. Both x86 and x64 variants are provided. kvm-61 or later is needed in the host. At the moment only binaries are available.

Hi,

This is great news!

Do you have any performance numbers for networking to see how it compares to the real hardware?

- Linux host (or: real Windows running on that host)
- PV Windows (network driver)
- non-PV Windows

Signature · 7 lines
Tomasz Chmielewski
http://wpkg.org

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#1 lore raw
Quoted 7 lines · Tomasz Chmielewski
Quoted 4 lines · Avi Kivity

This is the second release of network drivers for Windows guests running on a kvm host. The drivers are intended for Windows 2000 and Windows XP, and Windows 2003. Both x86 and x64 variants are provided. kvm-61 or later is needed in the host. At the moment only binaries are available.

Quoted 8 lines

Hi,

This is great news!

Do you have any performance numbers for networking to see how it compares to the real hardware?

- Linux host (or: real Windows running on that host)

For host you can measure yourself but for Linux guest (to host) it currently do about 1G, using TSO (work in progress) it can do 2.5G, and there is also work in progress to make the kernel know virtio through the tap interface which will further boot performance.

Quoted 1 line

- PV Windows (network driver)

About 700Mb+-, there is currently extra copy that we need to omit. Thanks for Anthony, we just have to change the driver.

Quoted 1 line

- non-PV Windows

What do you mean? Other fully emulated nics like e1000? It does not perform as pv but depending on the guest it can do up to 600Mb+-.

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#2 lore raw
Quoted 9 lines · Dor Laor
Quoted 4 lines

Do you have any performance numbers for networking to see how it compares to the real hardware?

- Linux host (or: real Windows running on that host)

For host you can measure yourself but for Linux guest (to host) it currently do about 1G, using TSO (work in progress) it can do 2.5G, and there is also work in progress to make the kernel know virtio through the tap interface which will further boot performance.

... with what kind of CPU utilization?

Quoted 4 lines
Quoted 1 line

- PV Windows (network driver)

About 700Mb+-, there is currently extra copy that we need to omit. Thanks for Anthony, we just have to change the driver.

Same question (although it's less interesting if we can't even saturate the pipe).

Quoted 5 lines
Quoted 1 line

- non-PV Windows

What do you mean? Other fully emulated nics like e1000? It does not perform as pv but depending on the guest it can do up to 600Mb+-.

Same question (although again it's less interesting if we can't even saturate the pipe).

Cheers,
Muli

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#3 lore raw
In reply to Dor Laor

Dor Laor schrieb:

(...)

Quoted 10 lines
Quoted 1 line

- PV Windows (network driver)

About 700Mb+-, there is currently extra copy that we need to omit. Thanks for Anthony, we just have to change the driver.

Quoted 1 line

- non-PV Windows

What do you mean? Other fully emulated nics like e1000? It does not perform as pv but depending on the guest it can do up to 600Mb+-.

Just generally, how Windows PV drivers help to improve network performance.

So, a PV network driver can do about 700Mb/s, and an emulated NIC can do about 600 Mb/s, Windows guest to host?

That would be about 20% improvement?

Signature · 8 lines
Tomasz Chmielewski
http://wpkg.org


-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#4 lore raw
Quoted 15 lines · Tomasz Chmielewski

Dor Laor schrieb:

(...)

Quoted 10 lines
Quoted 1 line

- PV Windows (network driver)

About 700Mb+-, there is currently extra copy that we need to omit. Thanks for Anthony, we just have to change the driver.

Quoted 1 line

- non-PV Windows

What do you mean? Other fully emulated nics like e1000? It does not perform as pv but depending on the guest it can do up to 600Mb+-.

Quoted 8 lines

Just generally, how Windows PV drivers help to improve network performance.

So, a PV network driver can do about 700Mb/s, and an emulated NIC can do about 600 Mb/s, Windows guest to host?

That would be about 20% improvement?

It's work in progress, doing zero copy in the guest, adding TSO, using virtio'd tap will drastically boot performance. There is no reason the performance won't match Linux guest.
Also I don't exactly remember the numbers but the gain in the tx pass is grater.

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#5 lore raw
Quoted 19 lines · Dor Laor
Quoted 17 lines · Tomasz Chmielewski

Dor Laor schrieb:

(...)

Quoted 12 lines
Quoted 2 lines

- PV Windows (network driver)

About 700Mb+-, there is currently extra copy that we need to omit. Thanks for Anthony, we just have to change the driver.

Quoted 2 lines

- non-PV Windows

What do you mean? Other fully emulated nics like e1000? It does not perform as pv but depending on the guest it can do up to 600Mb+-.

Quoted 7 lines
Quoted 7 lines

Just generally, how Windows PV drivers help to improve network performance.

So, a PV network driver can do about 700Mb/s, and an emulated NIC can do about 600 Mb/s, Windows guest to host?

That would be about 20% improvement?

FWIW, virtio-net is much better with my patches applied. The difference between the e1000 and virtio-net is that e1000 consumes almost twice as much CPU as virtio-net so in my testing, the performance improvement with virtio-net is about 2x. We were loosing about 20-30% throughput because of the delays in handling incoming packets.

Regards,

Anthony LIguori

Quoted 10 lines
Quoted 1 line

It's work in progress, doing zero copy in the guest, adding TSO, using virtio'd tap will drastically boot performance. There is no reason the performance won't match Linux guest.
Also I don't exactly remember the numbers but the gain in the tx pass is grater.

Quoted 9 lines

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
_______________________________________________
kvm-devel mailing list [email protected]
https://lists.sourceforge.net/lists/listinfo/kvm-devel

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#6 lore raw

Anthony Liguori schrieb:

(...)

Quoted 11 lines
Quoted 5 lines
Quoted 5 lines

So, a PV network driver can do about 700Mb/s, and an emulated NIC can do about 600 Mb/s, Windows guest to host?

That would be about 20% improvement?

FWIW, virtio-net is much better with my patches applied. The difference between the e1000 and virtio-net is that e1000 consumes almost twice as much CPU as virtio-net so in my testing, the performance improvement with virtio-net is about 2x. We were loosing about 20-30% throughput because of the delays in handling incoming packets.

Do you by chance have any recent numbers on disk performance (i.e., Windows guest vs Linux host)?

Signature · 7 lines
Tomasz Chmielewski
http://wpkg.org

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#7 lore raw
Quoted 10 lines · Tomasz Chmielewski

Anthony Liguori schrieb:

(...)

Quoted 6 lines
Quoted 5 lines
Quoted 5 lines

So, a PV network driver can do about 700Mb/s, and an emulated NIC can do about 600 Mb/s, Windows guest to host?

That would be about 20% improvement?

Quoted 10 lines
Quoted 5 lines

FWIW, virtio-net is much better with my patches applied. The difference between the e1000 and virtio-net is that e1000 consumes almost twice as much CPU as virtio-net so in my testing, the performance improvement with virtio-net is about 2x. We were loosing about 20-30% throughput because of the delays in handling incoming packets.

Do you by chance have any recent numbers on disk performance (i.e., Windows guest vs Linux host)?

At the moment there is no pv block driver for Windows guests. (there is for linux)
You can use scsi for windows, it should perform well.

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#8 lore raw

Dor Laor schrieb:

(...)

Quoted 5 lines
Quoted 5 lines
Quoted 5 lines

FWIW, virtio-net is much better with my patches applied. The difference between the e1000 and virtio-net is that e1000 consumes almost twice as much CPU as virtio-net so in my testing, the performance improvement with virtio-net is about 2x. We were loosing about 20-30% throughput because of the delays in handling incoming packets.

Quoted 8 lines
Quoted 4 lines

Do you by chance have any recent numbers on disk performance (i.e., Windows guest vs Linux host)?

At the moment there is no pv block driver for Windows guests. (there is for linux)
You can use scsi for windows, it should perform well.

How well, when compared to "bare metal"? Or when compared to a Linux guest with a pv block driver? Do you have any numbers?

Signature · 7 lines
Tomasz Chmielewski
http://wpkg.org

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#9 lore raw
In reply to Anthony Liguori
Quoted 1 line · Anthony Liguori

FWIW, virtio-net is much better with my patches applied.

The can_receive patches?

Again, I'm not opposed to them in principle, I just think that if they help that this points at a virtio deficiency. Virtio should never leave the rx queue empty. Consider the case where the virtio queue isn't tied to a socket buffer, but directly to hardware.

Signature · 7 lines
Do not meddle in the internals of kernels, for they are subtle and quick to panic.


-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#10 lore raw
Quoted 9 lines · Avi Kivity
Quoted 1 line · Anthony Liguori

FWIW, virtio-net is much better with my patches applied.

The can_receive patches?

Again, I'm not opposed to them in principle, I just think that if they help that this points at a virtio deficiency. Virtio should never leave the rx queue empty. Consider the case where the virtio queue isn't tied to a socket buffer, but directly to hardware.

For RX performance:

right now
[ 3] 0.0-10.0 sec 1016 MBytes 852 Mbits/sec

revert tap hack
[ 3] 0.0-10.0 sec 564 MBytes 473 Mbits/sec

all patches applied
[ 3] 0.0-10.0 sec 1.17 GBytes 1.01 Gbits/sec

drop lots of packets
[ 3] 0.0-10.0 sec 1.05 GBytes 905 Mbits/sec

The last patch is not in my series but it basically makes the ring size 512 and drops packets when we run out of descriptors. That was to valid that we're not hiding a virtio deficiency. The reason I want to buffer
packets is that it avoids having to deal with tuning. For
vringfd/vmdq, we'll have to make sure to get the tuning right though.

Regards,

Anthony Liguori

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/

#11 lore raw
Quoted 27 lines · Anthony Liguori
Quoted 9 lines · Avi Kivity
Quoted 1 line · Anthony Liguori

FWIW, virtio-net is much better with my patches applied.

The can_receive patches?

Again, I'm not opposed to them in principle, I just think that if they help that this points at a virtio deficiency. Virtio should never leave the rx queue empty. Consider the case where the virtio queue isn't tied to a socket buffer, but directly to hardware.

For RX performance:

right now
[ 3] 0.0-10.0 sec 1016 MBytes 852 Mbits/sec

revert tap hack
[ 3] 0.0-10.0 sec 564 MBytes 473 Mbits/sec

all patches applied
[ 3] 0.0-10.0 sec 1.17 GBytes 1.01 Gbits/sec

drop lots of packets
[ 3] 0.0-10.0 sec 1.05 GBytes 905 Mbits/sec

Quoted 5 lines

The last patch is not in my series but it basically makes the ring size 512 and drops packets when we run out of descriptors. That was to valid that we're not hiding a virtio deficiency. The reason I want
to buffer packets is that it avoids having to deal with tuning. For
vringfd/vmdq, we'll have to make sure to get the tuning right though.

Okay; I'll apply the patches. Hopefully we won't diverge too much from upstream qemu.

Signature · 7 lines
error compiling committee.c: too many arguments to function


-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft 
Defy all challenges. Microsoft(R) Visual Studio 2008. 
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
#12 lore raw
Quoted 35 lines · Avi Kivity
Quoted 27 lines · Anthony Liguori
Quoted 9 lines · Avi Kivity
Quoted 1 line · Anthony Liguori

FWIW, virtio-net is much better with my patches applied.

The can_receive patches?

Again, I'm not opposed to them in principle, I just think that if they help that this points at a virtio deficiency. Virtio should never leave the rx queue empty. Consider the case where the virtio queue isn't tied to a socket buffer, but directly to hardware.

For RX performance:

right now
[ 3] 0.0-10.0 sec 1016 MBytes 852 Mbits/sec

revert tap hack
[ 3] 0.0-10.0 sec 564 MBytes 473 Mbits/sec

all patches applied
[ 3] 0.0-10.0 sec 1.17 GBytes 1.01 Gbits/sec

drop lots of packets
[ 3] 0.0-10.0 sec 1.05 GBytes 905 Mbits/sec

Quoted 6 lines

The last patch is not in my series but it basically makes the ring size 512 and drops packets when we run out of descriptors. That was to valid that we're not hiding a virtio deficiency. The reason I want to buffer packets is that it avoids having to deal with
tuning. For vringfd/vmdq, we'll have to make sure to get the tuning
right though.

Quoted 2 lines

Okay; I'll apply the patches. Hopefully we won't diverge too much from upstream qemu.

I am going to push these upstream. I need to finish the page_desc cache first b/c right now the version of virtio that could go into upstream QEMU has unacceptable performance for KVM.

Regards,

Anthony Liguori

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008.