ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
PATCH 1/1 ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
From: Victor Gallardo <[email protected]>
--- cpu/ppc4xx/uic.c | 4 ++-- 1 files changed, 2 insertions(+), 2 deletions(-)
cpu/ppc4xx/uic.c +2 -2
@@ -129,11 +129,11 @@ void external_interrupt(struct pt_regs *regs)uic_interrupt (UIC3_DCR_BASE ,96 );#endif +mtdcr (uic0sr, (uic_msr &UICB0_ALL )); +if (uic_msr & ~(UICB0_ALL ))uic_interrupt (UIC0_DCR_BASE ,0 ); -mtdcr (uic0sr, uic_msr); -return ; }
Signature · 1 line
1.5.5
PATCH 1/1 ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
Dear vgallardo at amcc.com,
Can you please provide a real name with your mail address when submitting patches?
Quoted 1 line · In message <[email protected]> you wrote:
Subject: [U-Boot] [PATCH 1/1] ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
This is an awfully long subject line.
As you are probably aware, the Subject line will be used as part of the git commit message, and it will be shown as "title" of your patch by tools like "git log" or "gitk" etc.
However, these tools will truncate the line after 70 characters. That means, your commit message will read:
commit ...
Author: <[email protected]> Date: ...
ppc4xx: fix UIC hang if critical or non-critical interrupt is set at
This is not exactly useful, is it?
So please use SHORT subject lines and provide the explanation in the message body.
Thanks.
Best regards,
Wolfgang Denk
Signature · 5 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de Alles Gescheite ist schon gedacht worden, man mu? nur versuchen, es noch einmal zu denken. -- Goethe, Maximen und Reflexionen
PATCH 1/1 ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
Hi Wolfgang:
I send the patch out for Victor. In the original email the From
field did indicate his name.
Am I missing something?
Thanks
Feng Kan
Quoted 7 lines
Dear vgallardo at amcc.com,
Can you please provide a real name with your mail address when submitting patches?
PATCH 1/1 ppc4xx: fix UIC hang if critical or non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
Dear Feng Kan,
Quoted 3 lines · In message <[email protected]> you wrote:
I send the patch out for Victor. In the original email the From
field did indicate his name.
Am I missing something?
I don't know what you did, but there were actually two semi-identical postings:
------
Subject: [U-Boot] [PATCH 1/1] ppc4xx: fix UIC hang if critical or
non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
From: [email protected]
Date: Thu, 28 Aug 2008 13:53:11 -0700 (22:53 MEST)
To: u-boot at lists.denx.de
Cc: sr at denx.de
------
Subject: [U-Boot] [PATCH 1/1] ppc4xx: fix UIC hang if critical or
non-critical interrupt is set at the same time as a normal interrupt is set on UIC0
From: [email protected]
Date: Thu, 28 Aug 2008 13:55:14 -0700 (22:55 MEST)
To: u-boot at lists.denx.de
Cc: sr at denx.de
------
As you can see, both were sent about two minutes apart, and none of them had a realname in the From: field.
See also
http://lists.denx.de/pipermail/u-boot/2008-August/039566.html and
http://lists.denx.de/pipermail/u-boot/2008-August/039567.html
Best regards,
Wolfgang Denk
Signature · 5 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de As long as we're going to reinvent the wheel again, we might as well try making it round this time. - Mike Dennison