Skip to contentSkip to conversation

Prototype Fencing Agent for Raritan eRIC G4

Cluster-devel Gordan Bobic 3 participants 4 messages Jun 9, 2009 – Jun 11, 2009

lore
Share & tools
lore
#0 lore raw

As the subject line says. The agent is attached.
As all currently included fencing agents, this one is also written in Perl, and has the same requirements and dependencies as the DRAC fencing agent (Net::Telnet, Getopt::Std).

What does it take to get it included in the distro? ;)

Many thanks.

Gordan
-------------- next part --------------
An embedded and charset-unspecified text was scrubbed...
Name: fence_eric
URL: <http://listman.redhat.com/archives/cluster-devel/attachments/20090609/d8aaa072/attachment.ksh>

#1 lore raw
Quoted 11 lines · Gordan Bobic

As the subject line says. The agent is attached.
As all currently included fencing agents, this one is also written in Perl, and has the same requirements and dependencies as the DRAC fencing agent (Net::Telnet, Getopt::Std).

What does it take to get it included in the distro? ;)

Many thanks.

Gordan

Hi Gordan

Would it be possible to look at migrating this agent to SSH (more secure) or to SNMP (less screen scraping)?

Look at fence_cisco as an example of snmp usage.

Long term maintainability of screen scraping is an issue with firmware changes.

Also it seems that card has IPMI support. If so, can use test with fence_ipmi? Would remove the need for yet-another-agent ;)

-regards
Subhendu

Signature · 3 lines
Subhendu Ghosh
Red Hat
Email: sghosh at redhat.com
#2 lore raw
Quoted 1 line · Subhendu Ghosh

Would it be possible to look at migrating this agent to SSH (more secure)

I started with the idea of doing it over ssh, but Net::SSH module seemed to be a lot less forgiving about the terminal quirkyness. I can have another go. There's also the issue of manual intervention being required to save the signatures (and where do the known hosts go?).

Quoted 1 line

or to SNMP (less screen scraping)?

Hmm, maybe. I haven't looked into the SNMP capability on the device, but it looks like it'll work, and probably be easier to do than SSH.

Quoted 1 line

Look at fence_cisco as an example of snmp usage.

Assuming they speak a compatible dialect, which may not be the case. I'll have a look.

Quoted 1 line

Long term maintainability of screen scraping is an issue with firmware changes.

Tell me about it. I submitted a patch for fence_drac a while back to address an issue that seems to have arisen from a firmware update inducted pattern match failure.

Not only that, but I've discovered a bug on the latest eRIC G4 firmware
- 04.02.00-7153 seems to have broken USB keyboard support (you'd think this was important on a remote console device!) and potentially some power button press dodgyness. The previous firmware, however - 04.02.00-6505, works OK.

Quoted 2 lines

Also it seems that card has IPMI support. If so, can use test with fence_ipmi? Would remove the need for yet-another-agent ;)

Sadly, my servers with these cards in them don't have IPMI support. The card only proxies it. The card supports direct power/reset button control in addition to IPMI, so this is what I'm using. But as you can see from the code, it operates only on the power on/off even for a reboot because the said servers also don't have a reset connector. I wrote this agent because I _needed_ it. :)

But I'll look into the SNMP way of doing it, it sounds like it might be neater. I'll add it as an option since the telnet way is already written. What parameter should/can be used to specify such things, that is available from a cluster.conf reference?

Thanks.

Gordan

#3 lore raw

Gordan,

Quoted 11 lines · Gordan Bobic
Quoted 1 line · Subhendu Ghosh

Would it be possible to look at migrating this agent to SSH (more secure)

I started with the idea of doing it over ssh, but Net::SSH module seemed to be a lot less forgiving about the terminal quirkyness. I can have another go. There's also the issue of manual intervention being required to save the signatures (and where do the known hosts go?).

Quoted 1 line

or to SNMP (less screen scraping)?

Quoted 7 lines

Hmm, maybe. I haven't looked into the SNMP capability on the device, but it looks like it'll work, and probably be easier to do than SSH.

Quoted 1 line

Look at fence_cisco as an example of snmp usage.

Assuming they speak a compatible dialect, which may not be the case. I'll have a look.

We are using fence agents library, which makes writing agents easier (capable of doing things like command line parsing, implement reboot operation, ...), shorter and easier to maintain. fence_cisco is good example (short, tested, ...) HOW to write such agent. Agents are written in Python, and we are migrating all agents on top of library.

Quoted 25 lines
Quoted 3 lines

Long term maintainability of screen scraping is an issue with firmware changes.

Tell me about it. I submitted a patch for fence_drac a while back to address an issue that seems to have arisen from a firmware update inducted pattern match failure.

Not only that, but I've discovered a bug on the latest eRIC G4 firmware
- 04.02.00-7153 seems to have broken USB keyboard support (you'd think this was important on a remote console device!) and potentially some power button press dodgyness. The previous firmware, however - 04.02.00-6505, works OK.

Quoted 3 lines

Also it seems that card has IPMI support. If so, can use test with fence_ipmi?
Would remove the need for yet-another-agent ;)

Sadly, my servers with these cards in them don't have IPMI support. The card only proxies it. The card supports direct power/reset button control in addition to IPMI, so this is what I'm using. But as you can see from the code, it operates only on the power on/off even for a reboot because the said servers also don't have a reset connector. I wrote this agent because I _needed_ it. :)

Quoted 4 lines

But I'll look into the SNMP way of doing it, it sounds like it might be neater. I'll add it as an option since the telnet way is already written. What parameter should/can be used to specify such things, that is available from a cluster.conf reference?

This question answers you little look to fence_cisco agent (or you can use fence_ifmib, fence_intel_modular, fence_apc_snmp, ...). In case you will not understand something, please ask.

Quoted 5 lines

Thanks.

Gordan

Regards,
Honza