Skip to contentSkip to conversation

Add a subtest pci_hotplug in kvm test

PATCH In review Yolkfull Chow 2 participants 5 messages Jul 3, 2009 – Jul 15, 2009 KVM

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 Add a subtest pci_hotplug in kvm test

---
 client/tests/kvm/kvm.py               |    1 +
 client/tests/kvm/kvm_tests.cfg.sample |   65 ++++++++++++++++++++++-
 client/tests/kvm/kvm_tests.py         |   94 +++++++++++++++++++++++++++++++++
 client/tests/kvm/kvm_vm.py            |    2 +
 4 files changed, 161 insertions(+), 1 deletions(-)
client/tests/kvm/kvm.py +1 -0
index b18b643..fc92e10 100644
@@ -55,6 +55,7 @@ class kvm(test.test):
                 "kvm_install":  test_routine("kvm_install", "run_kvm_install"),
                 "linux_s3":     test_routine("kvm_tests", "run_linux_s3"),
                 "stress_boot":  test_routine("kvm_tests", "run_stress_boot"),
+                "pci_hotplug":  test_routine("kvm_tests", "run_pci_hotplug"),
                 }
 
         # Make it possible to import modules from the test's bindir
client/tests/kvm/kvm_tests.cfg.sample +64 -1

80 lines not on this page · raw message

client/tests/kvm/kvm_tests.py +94 -0

97 lines not on this page · raw message

client/tests/kvm/kvm_vm.py +2 -0
index 503f636..95b55eb 100644
@@ -239,6 +239,8 @@ class VM:
 
         for image_name in kvm_utils.get_sub_dict_names(params, "images"):
             image_params = kvm_utils.get_sub_dict(params, image_name)
+            if image_params.get("boot_drive") == "no":
+                continue
             qemu_cmd += " -drive file=%s" % get_image_filename(image_params,
                                                                image_dir)
             if image_params.get("drive_format"):
Signature · 1 line
1.6.2.5
#1 lore raw
Quoted 89 lines · Yolkfull Chow
---
  client/tests/kvm/kvm.py               |    1 +
  client/tests/kvm/kvm_tests.cfg.sample |   65 ++++++++++++++++++++++-
  client/tests/kvm/kvm_tests.py         |   94 +++++++++++++++++++++++++++++++++
  client/tests/kvm/kvm_vm.py            |    2 +
  4 files changed, 161 insertions(+), 1 deletions(-)
client/tests/kvm/kvm.py +1 -0
index b18b643..fc92e10 100644
@@ -55,6 +55,7 @@ class kvm(test.test):
                  "kvm_install":  test_routine("kvm_install", "run_kvm_install"),
                  "linux_s3":     test_routine("kvm_tests", "run_linux_s3"),
                  "stress_boot":  test_routine("kvm_tests", "run_stress_boot"),
+                "pci_hotplug":  test_routine("kvm_tests", "run_pci_hotplug"),
                  }
 
          # Make it possible to import modules from the test's bindir
client/tests/kvm/kvm_tests.cfg.sample +54 -0
index 2f864de..a9e16d6 100644
@@ -94,6 +94,53 @@ variants:
          max_vms = 5
          alive_test_cmd = ps aux
 
+
+    - nic_hotplug:
+        type = pci_hotplug
+        pci_type = nic
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
+        pci_test_cmd = 'nslookup www.redhat.com'
+        seconds_wait_for_device_install = 3
+        variants:
+            - @nic_8139:
+                pci_model = rtl8139
+                match_string = "8139"
+            - nic_virtio:
+                pci_model = virtio
+                match_string = "Virtio network device"
+            - nic_e1000:
+                pci_model = e1000
+                match_string = "Gigabit Ethernet Controller"
+
+    - block_hotplug:
+        type = pci_hotplug
+        pci_type = block
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
+        images += " stg"
+        boot_drive_stg = no
+        image_name_stg = storage
+        image_size = 1G
+        force_create_image_stg = yes
+        pci_test_cmd = 'dir'
+        seconds_wait_for_device_install = 3
+        variants:
+            - block_virtio:
+                pci_model = virtio
+                match_string = "Virtio block device"
+            - block_scsi:
+                pci_model = scsi
+                match_string = "SCSI storage controller"
+        variants:
+            - fmt_qcow2:
+                image_format_stg = qcow2
+            - fmt_raw:
+                image_format_stg = raw
+
+
  # NICs
  variants:
      - @rtl8139:
@@ -306,6 +353,22 @@ variants:
              migration_test_command = ver&&  vol
          stress_boot:
              alive_test_cmd = systeminfo
+        nic_hotplug:
+            modprobe_acpiphp = no
+            reference_cmd = systeminfo
+            seconds_wait_for_device_install = 10
+            find_pci_cmd = ipconfig /all | find "Description"
+            nic_e1000:
+                match_string = "Intel(R) PRO/1000 MT Network Connection"

client/tests/kvm/kvm_tests.cfg.sample variants: · line 372

Quoted 10 lines
client/tests/kvm/kvm_tests.cfg.sample +9 -0
+        block_hotplug:
+            use_telnet = yes
+            modprobe_acpiphp = no
+            reference_cmd = wmic diskdrive
+            find_pci_cmd = wmic diskdrive | find "disk drives"
+            seconds_wait_for_device_install = 10
+            only block_scsi
+            block_scsi:
+                match_string = "SCSI"
 

It supports Windows block_hotplug now. But we need use_telnet to login Windows OS since command 'wmic' could only run on telnet session.

Quoted 125 lines
client/tests/kvm/kvm_tests.cfg.sample +1 -1
          variants:
              - Win2000:
@@ -571,4 +634,4 @@ variants:
          only rtl8139
 
  # Choose your test list
-only fc8_quick
+#only fc8_quick
client/tests/kvm/kvm_tests.py +94 -0
index 2d11fed..230385a 100644
@@ -585,3 +585,97 @@ def run_stress_boot(tests, params, env):
          for se in sessions:
              se.close()
          logging.info("Total number booted: %d" % (num -1))
+
+
+def run_pci_hotplug(test, params, env):
+    """
+    Test pci devices' hotplug
+    1) pci_add a deivce (nic or storage)
+    2) Compare 'info pci' output
+    3) Compare $reference_cmd output
+    4) Verify whether pci_model is shown in $pci_find_cmd
+    5) pci_del the device, verify whether could remove the pci device
+
+    @param test:   kvm test object
+    @param params: Dictionary with the test parameters
+    @param env:    Dictionary with test environment.
+    """
+    vm = kvm_utils.env_get_vm(env, params.get("main_vm"))
+    if not vm:
+        raise error.TestError("VM object not found in environment")
+    if not vm.is_alive():
+        raise error.TestError("VM seems to be dead; Test requires a living VM")
+
+    logging.info("Waiting for guest to be up...")
+
+    session = kvm_utils.wait_for(vm.ssh_login, 240, 0, 2)
+    if not session:
+        raise error.TestFail("Could not log into guest")
+
+    logging.info("Logged in")
+
+    # modprobe the module that enable hotplug
+    if params.get("modprobe_acpiphp") == "yes":
+        if session.get_command_status("modprobe acpiphp"):
+            raise error.TestError("Modprobe module 'acpiphp' failed")
+
+    # get reference output
+    s, info_pci_ref = vm.send_monitor_cmd("info pci")
+
+    # compare the output of `reference_cmd`
+    ref_cmd = params.get("reference_cmd")
+    reference = session.get_command_output(ref_cmd)
+
+    # implement pci hotplug
+    tested_model = params.get("pci_model")
+    logging.info("Testing hotplug pci device:%s" % tested_model)
+
+    test_type = params.get("pci_type")
+    if test_type == "nic":
+        pci_add_cmd = "pci_add pci_addr=auto nic model=%s" % tested_model
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)
+
+    elif test_type == "block":
+        image_name = params.get("image_name_stg")
+        image_format = params.get("image_format_stg", "qcow2")
+        image_filename = "%s.%s" % (image_name, image_format)
+        image_dir = os.path.join(test.bindir, "images")
+        storage_name = os.path.join(image_dir, image_filename)
+        pci_add_cmd = "pci_add pci_addr=auto storage file=%s,if=%s" % \
+                                              (storage_name, tested_model)
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)
+
+    if not "OK domain" in add_output:
+        raise error.TestFail("Command failed: %s" % pci_add_cmd)
+
+    # compare the output of 'info pci'
+    s, after_add = vm.send_monitor_cmd("info pci")
+    if after_add == info_pci_ref:
+        raise error.TestFail("No new pci device shown in 'info pci'")
+
+    time.sleep(int(params.get("seconds_wait_for_device_install")))
+
+    o = session.get_command_output(ref_cmd)
+    if reference == o:
+        raise error.TestFail("No new device shown in cmd: %s" % ref_cmd)
+
+    cmd = params.get("find_pci_cmd")
+    output = session.get_command_output(cmd)
+    if not params.get("match_string") in output:
+        raise error.TestFail("Not found pci model: %s; Command is: %s" %
+                                                    (tested_model, cmd))
+
+    # del pci device
+    slot_id = "0" + add_output.split(",")[2].split()[1]
+    cmd = "pci_del pci_addr=%s" % slot_id
+    s, after_del = vm.send_monitor_cmd(cmd)
+    if after_del == after_add:
+        raise error.TestFail("Failed to hot remove pci device:%s; Command:%s" %
+                                                     (tested_model, cmd))
+
+    # check whether VM's network&  disk work fine
+    if session.get_command_status(params.get("pci_test_cmd")):
+        raise error.TestFail("Check for %s device failed after PCI hotplug" %
+                                                                 test_type)
+
+    session.close()
client/tests/kvm/kvm_vm.py +2 -0
index 503f636..95b55eb 100644
@@ -239,6 +239,8 @@ class VM:
 
          for image_name in kvm_utils.get_sub_dict_names(params, "images"):
              image_params = kvm_utils.get_sub_dict(params, image_name)
+            if image_params.get("boot_drive") == "no":
+                continue
              qemu_cmd += " -drive file=%s" % get_image_filename(image_params,
                                                                 image_dir)
              if image_params.get("drive_format"):
Signature · 2 lines
Yolkfull
Regards,
#2 lore raw

I've spent some time doing a second review and test of the code. During my tests:

* I found some problems with PCI hotplug itself and would like help
to figure out why things are not working as expected.
* Made suggestions regarding the phrasing of the error messages
thrown by the test. Mostly nipticking. Let me know if you think the new messages make sense.
* The order of the final test steps looks a bit weird to me

Comments follow.

Quoted 29 lines · Yolkfull Chow
Quoted 28 lines · Yolkfull Chow

---
  client/tests/kvm/kvm.py               |    1 + client/tests/kvm/kvm_tests.cfg.sample |   65 ++++++++++++++++++++++- client/tests/kvm/kvm_tests.py         |   94 +++++++++++++++++++++++++++++++++ client/tests/kvm/kvm_vm.py            |    2 +

  4 files changed, 161 insertions(+), 1 deletions(-)
client/tests/kvm/kvm.py +1 -0
index b18b643..fc92e10 100644
@@ -55,6 +55,7 @@ class kvm(test.test):
                   "kvm_install":  test_routine("kvm_install", "run_kvm_install"),
                   "linux_s3":     test_routine("kvm_tests", "run_linux_s3"),
                   "stress_boot":  test_routine("kvm_tests", "run_stress_boot"),
+                "pci_hotplug":  test_routine("kvm_tests", "run_pci_hotplug"),
                   }
 
           # Make it possible to import modules from the test's bindir
client/tests/kvm/kvm_tests.cfg.sample +0 -0
index 2f864de..a9e16d6 100644
@@ -94,6 +94,53 @@ variants:

          max_vms = 5
          alive_test_cmd = ps aux

Quoted 7 lines
Quoted 7 lines

+
+    - nic_hotplug:
+        type = pci_hotplug
+        pci_type = nic
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'

I tried block device hotplug, lspci doesn't show up the newly added devices. Already tried with F8 and F9. Any idea why?

Quoted 4 lines
Quoted 4 lines

+        pci_test_cmd = 'nslookup www.redhat.com'
+        seconds_wait_for_device_install = 3
+        variants:
+            - @nic_8139:

Quoted 8 lines
Quoted 8 lines

+                pci_model = rtl8139
+                match_string = "8139"
+            - nic_virtio:
+                pci_model = virtio
+                match_string = "Virtio network device"
+            - nic_e1000:
+                pci_model = e1000
+                match_string = "Gigabit Ethernet Controller"

Pretty much all block hotplug 'guest side check' is failing during the stage where the output of lspci | tail -n1 is being compared with the match strings. Hypervisor is qemu 0.10.5 (kvm-87 upstream).

Quoted 72 lines
Quoted 42 lines

+    - block_hotplug:
+        type = pci_hotplug
+        pci_type = block
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
+        images += " stg"
+        boot_drive_stg = no
+        image_name_stg = storage
+        image_size = 1G
+        force_create_image_stg = yes
+        pci_test_cmd = 'dir'
+        seconds_wait_for_device_install = 3
+        variants:
+            - block_virtio:
+                pci_model = virtio
+                match_string = "Virtio block device"
+            - block_scsi:
+                pci_model = scsi
+                match_string = "SCSI storage controller"
+        variants:
+            - fmt_qcow2:
+                image_format_stg = qcow2
+            - fmt_raw:
+                image_format_stg = raw

client/tests/kvm/kvm_tests.cfg.sample +2 -0
+
+

  # NICs
  variants:
      - @rtl8139:

client/tests/kvm/kvm_tests.cfg.sample +0 -0
@@ -306,6 +353,22 @@ variants:

              migration_test_command = ver&&  vol stress_boot:
              alive_test_cmd = systeminfo
+        nic_hotplug:
+            modprobe_acpiphp = no
+            reference_cmd = systeminfo
+            seconds_wait_for_device_install = 10
+            find_pci_cmd = ipconfig /all | find "Description"
+            nic_e1000:
+                match_string = "Intel(R) PRO/1000 MT Network Connection"
+        block_hotplug:

Quoted 9 lines

+            use_telnet = yes
+            modprobe_acpiphp = no
+            reference_cmd = wmic diskdrive
+            find_pci_cmd = wmic diskdrive | find "disk drives"
+            seconds_wait_for_device_install = 10
+            only block_scsi
+            block_scsi:
+                match_string = "SCSI"

It supports Windows block_hotplug now. But we need use_telnet to login Windows OS since command 'wmic' could only run on telnet session.

Quoted 19 lines

          variants:
              - Win2000:

client/tests/kvm/kvm_tests.cfg.sample +0 -0
@@ -571,4 +634,4 @@ variants:

          only rtl8139

  # Choose your test list

client/tests/kvm/kvm_tests.cfg.sample +1 -1
-only fc8_quick
+#only fc8_quick
client/tests/kvm/kvm_tests.py +0 -0
index 2d11fed..230385a 100644
@@ -585,3 +585,97 @@ def run_stress_boot(tests, params, env):

          for se in sessions:
              se.close()
          logging.info("Total number booted: %d" % (num -1))

client/tests/kvm/kvm_tests.py +2 -0
+
+
Quoted 8 lines
Quoted 8 lines

+def run_pci_hotplug(test, params, env):
+    """
+    Test pci devices' hotplug
+    1) pci_add a deivce (nic or storage)
+    2) Compare 'info pci' output
+    3) Compare $reference_cmd output
+    4) Verify whether pci_model is shown in $pci_find_cmd
+    5) pci_del the device, verify whether could remove the pci device

What about if the last steps were

5) Verify if the newly added devices are working properly
6) pci_del the device, verify whether could remove the pci device

6) is already happening in the code, but in reverse order than mentioned above.

Quoted 30 lines
Quoted 30 lines

+    @param test:   kvm test object
+    @param params: Dictionary with the test parameters
+    @param env:    Dictionary with test environment.
+    """
+    vm = kvm_utils.env_get_vm(env, params.get("main_vm"))
+    if not vm:
+        raise error.TestError("VM object not found in environment")
+    if not vm.is_alive():
+        raise error.TestError("VM seems to be dead; Test requires a living VM")

client/tests/kvm/kvm_tests.py +21 -0
+
+    logging.info("Waiting for guest to be up...")
+
+    session = kvm_utils.wait_for(vm.ssh_login, 240, 0, 2)
+    if not session:
+        raise error.TestFail("Could not log into guest")
+
+    logging.info("Logged in")
+
+    # modprobe the module that enable hotplug
+    if params.get("modprobe_acpiphp") == "yes":
+        if session.get_command_status("modprobe acpiphp"):
+            raise error.TestError("Modprobe module 'acpiphp' failed")
+
+    # get reference output
+    s, info_pci_ref = vm.send_monitor_cmd("info pci")
+
+    # compare the output of `reference_cmd`
+    ref_cmd = params.get("reference_cmd")
+    reference = session.get_command_output(ref_cmd)
+
Quoted 8 lines
Quoted 8 lines

+    # implement pci hotplug
+    tested_model = params.get("pci_model")
+    logging.info("Testing hotplug pci device:%s" % tested_model) +
+    test_type = params.get("pci_type")
+    if test_type == "nic":
+        pci_add_cmd = "pci_add pci_addr=auto nic model=%s" % tested_model
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)

The command

s, add_output = vm.send_monitor_cmd(pci_add_cmd)

Can be moved out the if blocks since it will be executed in both paths, we save one line of code with this (and it's cleaner anyway).

Quoted 8 lines
Quoted 8 lines

+    elif test_type == "block":
+        image_name = params.get("image_name_stg")
+        image_format = params.get("image_format_stg", "qcow2")
+        image_filename = "%s.%s" % (image_name, image_format)
+        image_dir = os.path.join(test.bindir, "images")
+        storage_name = os.path.join(image_dir, image_filename)
+        pci_add_cmd = "pci_add pci_addr=auto storage file=%s,if=%s" % \
+                                              (storage_name, tested_model)

The above line would be better with implicit line continuation

pci_add_cmd = ("pci_add pci_addr=auto storage file=%s,if=%s" %
(storage_name, tested_model))

Quoted 4 lines
Quoted 4 lines

+        s, add_output = vm.send_monitor_cmd(pci_add_cmd) +
+    if not "OK domain" in add_output:
+        raise error.TestFail("Command failed: %s" % pci_add_cmd)

Since we're executing a command on the hypervisor to add the device, a better way to put the above message would be

if not "OK domain" in add_output:
raise error.TestFail("Hypervisor command to add device '%s'failed."
"Output: %s" % (pci_add_cmd, add_output))

Quoted 4 lines
Quoted 4 lines

+    # compare the output of 'info pci'
+    s, after_add = vm.send_monitor_cmd("info pci")
+    if after_add == info_pci_ref:
+        raise error.TestFail("No new pci device shown in 'info pci'")

Another suggestion:

raise error.TestFail("No new PCI device shown after executing "
"hypervisor command 'info pci'")

Quoted 5 lines
Quoted 5 lines

+    time.sleep(int(params.get("seconds_wait_for_device_install"))) +
+    o = session.get_command_output(ref_cmd)
+    if reference == o:
+        raise error.TestFail("No new device shown in cmd: %s" % ref_cmd)

I found useful to explain on which side of the check the test fail, 'hypervisor', or 'guest'

raise error.TestFail("No new device shown on guest command %s output" %
ref_cmd)

Quoted 5 lines
Quoted 5 lines

+    cmd = params.get("find_pci_cmd")
+    output = session.get_command_output(cmd)
+    if not params.get("match_string") in output:
+        raise error.TestFail("Not found pci model: %s; Command is: %s" %
+                                                    (tested_model, cmd))

raise error.TestFail("PCI device model '%s' not found on host "
"command '%s' ouput" % (tested_model, cmd))

Quoted 7 lines
Quoted 7 lines

+    # del pci device
+    slot_id = "0" + add_output.split(",")[2].split()[1]
+    cmd = "pci_del pci_addr=%s" % slot_id
+    s, after_del = vm.send_monitor_cmd(cmd)
+    if after_del == after_add:
+        raise error.TestFail("Failed to hot remove pci device:%s; Command:%s" %
+                                                     (tested_model, cmd))

raise error.TestFail("Failed to hot remove pci device '%s'. "
"Hypervisor command: '%s'" % (tested_model, cmd))

Hot remove doesn't work for me either... Since we are here, I still didn't understand why we do a hot remove of a device and right below it we try to verify if the newly added devices are working properly. Shouldn't be the other way around (ie checking and then hot removing)?

Quoted 19 lines
Quoted 19 lines

+    # check whether VM's network&  disk work fine
+    if session.get_command_status(params.get("pci_test_cmd")):
+        raise error.TestFail("Check for %s device failed after PCI hotplug" %
+                                                                 test_type)

client/tests/kvm/kvm_tests.py +2 -0
+
+    session.close()
client/tests/kvm/kvm_vm.py +0 -0
index 503f636..95b55eb 100644
@@ -239,6 +239,8 @@ class VM:
 

          for image_name in kvm_utils.get_sub_dict_names(params, "images"):
              image_params = kvm_utils.get_sub_dict(params, image_name)
+            if image_params.get("boot_drive") == "no":
+                continue
              qemu_cmd += " -drive file=%s" % get_image_filename(image_params, image_dir) if image_params.get("drive_format"):

#3 lore raw
Quoted 12 lines · Lucas Meneghel Rodrigues

I've spent some time doing a second review and test of the code. During my tests:

* I found some problems with PCI hotplug itself and would like help
to figure out why things are not working as expected.
* Made suggestions regarding the phrasing of the error messages
thrown by the test. Mostly nipticking. Let me know if you think the new messages make sense.
* The order of the final test steps looks a bit weird to me

Comments follow.

Lucas, sorry for reply you a little late since I left two days. :)

Quoted 32 lines · Yolkfull Chow
Quoted 31 lines · Yolkfull Chow
Quoted 29 lines
---
   client/tests/kvm/kvm.py               |    1 +
   client/tests/kvm/kvm_tests.cfg.sample |   65 ++++++++++++++++++++++-
   client/tests/kvm/kvm_tests.py         |   94 +++++++++++++++++++++++++++++++++
   client/tests/kvm/kvm_vm.py            |    2 +
   4 files changed, 161 insertions(+), 1 deletions(-)
client/tests/kvm/kvm.py +1 -0
index b18b643..fc92e10 100644
@@ -55,6 +55,7 @@ class kvm(test.test):
                   "kvm_install":  test_routine("kvm_install", "run_kvm_install"),
                   "linux_s3":     test_routine("kvm_tests", "run_linux_s3"),
                   "stress_boot":  test_routine("kvm_tests", "run_stress_boot"),
+                "pci_hotplug":  test_routine("kvm_tests", "run_pci_hotplug"),
                   }
 
           # Make it possible to import modules from the test's bindir
client/tests/kvm/kvm_tests.cfg.sample +0 -0
index 2f864de..a9e16d6 100644
@@ -94,6 +94,53 @@ variants:
           max_vms = 5
           alive_test_cmd = ps aux
 
Quoted 11 lines
Quoted 8 lines

client/tests/kvm/kvm_tests.cfg.sample variants:

Quoted 8 lines
client/tests/kvm/kvm_tests.cfg.sample +7 -0
+
+    - nic_hotplug:
+        type = pci_hotplug
+        pci_type = nic
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
 

I tried block device hotplug, lspci doesn't show up the newly added devices. Already tried with F8 and F9. Any idea why?

Strange, it could be run successfully with guest RHEL.5.3.i386 and Win2008.32(use telnet login), but I never run it on Fedora. Jason reminded me several days ago that there is no 'acpiphp' module on Fedora which may be related. Anyway, I will fix it.

Quoted 257 lines
Quoted 14 lines
Quoted 4 lines
client/tests/kvm/kvm_tests.cfg.sample +3 -0
+        pci_test_cmd = 'nslookup www.redhat.com'
+        seconds_wait_for_device_install = 3
+        variants:

client/tests/kvm/kvm_tests.cfg.sample variants:

Quoted 10 lines
client/tests/kvm/kvm_tests.cfg.sample +9 -0
+            - @nic_8139:
+                pci_model = rtl8139
+                match_string = "8139"
+            - nic_virtio:
+                pci_model = virtio
+                match_string = "Virtio network device"
+            - nic_e1000:
+                pci_model = e1000
+                match_string = "Gigabit Ethernet Controller"
 

Pretty much all block hotplug 'guest side check' is failing during the stage where the output of lspci | tail -n1 is being compared with the match strings. Hypervisor is qemu 0.10.5 (kvm-87 upstream).

Quoted 74 lines
Quoted 42 lines
client/tests/kvm/kvm_tests.cfg.sample +35 -0
+    - block_hotplug:
+        type = pci_hotplug
+        pci_type = block
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
+        images += " stg"
+        boot_drive_stg = no
+        image_name_stg = storage
+        image_size = 1G
+        force_create_image_stg = yes
+        pci_test_cmd = 'dir'
+        seconds_wait_for_device_install = 3
+        variants:
+            - block_virtio:
+                pci_model = virtio
+                match_string = "Virtio block device"
+            - block_scsi:
+                pci_model = scsi
+                match_string = "SCSI storage controller"
+        variants:
+            - fmt_qcow2:
+                image_format_stg = qcow2
+            - fmt_raw:
+                image_format_stg = raw
+
+
   # NICs
   variants:
       - @rtl8139:
@@ -306,6 +353,22 @@ variants:
               migration_test_command = ver&&    vol
           stress_boot:
               alive_test_cmd = systeminfo
+        nic_hotplug:
+            modprobe_acpiphp = no
+            reference_cmd = systeminfo
+            seconds_wait_for_device_install = 10
+            find_pci_cmd = ipconfig /all | find "Description"
+            nic_e1000:
+                match_string = "Intel(R) PRO/1000 MT Network Connection"
+        block_hotplug:

client/tests/kvm/kvm_tests.cfg.sample variants: · line 373

Quoted 10 lines
client/tests/kvm/kvm_tests.cfg.sample +8 -0
+            use_telnet = yes
+            modprobe_acpiphp = no
+            reference_cmd = wmic diskdrive
+            find_pci_cmd = wmic diskdrive | find "disk drives"
+            seconds_wait_for_device_install = 10
+            only block_scsi
+            block_scsi:
+                match_string = "SCSI"
 
 

It supports Windows block_hotplug now. But we need use_telnet to login Windows OS since command 'wmic' could only run on telnet session.

Quoted 19 lines
client/tests/kvm/kvm_tests.cfg.sample +0 -0
           variants:

- Win2000:

client/tests/kvm/kvm_tests.cfg.sample +1 -1
@@ -571,4 +634,4 @@ variants:
           only rtl8139
 
   # Choose your test list
-only fc8_quick
+#only fc8_quick
client/tests/kvm/kvm_tests.py +3 -0
index 2d11fed..230385a 100644
@@ -585,3 +585,97 @@ def run_stress_boot(tests, params, env):
           for se in sessions:
               se.close()
           logging.info("Total number booted: %d" % (num -1))
+
+
+def run_pci_hotplug(test, params, env):
Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 597

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    """
+    Test pci devices' hotplug
+    1) pci_add a deivce (nic or storage)
+    2) Compare 'info pci' output
+    3) Compare $reference_cmd output
+    4) Verify whether pci_model is shown in $pci_find_cmd
+    5) pci_del the device, verify whether could remove the pci device

What about if the last steps were

5) Verify if the newly added devices are working properly
6) pci_del the device, verify whether could remove the pci device

6) is already happening in the code, but in reverse order than mentioned above.

Quoted 31 lines
Quoted 31 lines
client/tests/kvm/kvm_tests.py +31 -0
+    @param test:   kvm test object
+    @param params: Dictionary with the test parameters
+    @param env:    Dictionary with test environment.
+    """
+    vm = kvm_utils.env_get_vm(env, params.get("main_vm"))
+    if not vm:
+        raise error.TestError("VM object not found in environment")
+    if not vm.is_alive():
+        raise error.TestError("VM seems to be dead; Test requires a living VM")
+
+    logging.info("Waiting for guest to be up...")
+
+    session = kvm_utils.wait_for(vm.ssh_login, 240, 0, 2)
+    if not session:
+        raise error.TestFail("Could not log into guest")
+
+    logging.info("Logged in")
+
+    # modprobe the module that enable hotplug
+    if params.get("modprobe_acpiphp") == "yes":
+        if session.get_command_status("modprobe acpiphp"):
+            raise error.TestError("Modprobe module 'acpiphp' failed")
+
+    # get reference output
+    s, info_pci_ref = vm.send_monitor_cmd("info pci")
+
+    # compare the output of `reference_cmd`
+    ref_cmd = params.get("reference_cmd")
+    reference = session.get_command_output(ref_cmd)
+
+    # implement pci hotplug
Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 636

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    tested_model = params.get("pci_model")
+    logging.info("Testing hotplug pci device:%s" % tested_model)
+
+    test_type = params.get("pci_type")
+    if test_type == "nic":
+        pci_add_cmd = "pci_add pci_addr=auto nic model=%s" % tested_model
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)

The command

s, add_output = vm.send_monitor_cmd(pci_add_cmd)

Can be moved out the if blocks since it will be executed in both paths, we save one line of code with this (and it's cleaner anyway).

Quoted 9 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 645

Quoted 9 lines
client/tests/kvm/kvm_tests.py +8 -0
+    elif test_type == "block":
+        image_name = params.get("image_name_stg")
+        image_format = params.get("image_format_stg", "qcow2")
+        image_filename = "%s.%s" % (image_name, image_format)
+        image_dir = os.path.join(test.bindir, "images")
+        storage_name = os.path.join(image_dir, image_filename)
+        pci_add_cmd = "pci_add pci_addr=auto storage file=%s,if=%s" % \
+                                              (storage_name, tested_model)

The above line would be better with implicit line continuation

pci_add_cmd = ("pci_add pci_addr=auto storage file=%s,if=%s" %
(storage_name, tested_model))

Quoted 5 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 649

Quoted 5 lines
client/tests/kvm/kvm_tests.py +4 -0
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)
+
+    if not "OK domain" in add_output:
+        raise error.TestFail("Command failed: %s" % pci_add_cmd)

Since we're executing a command on the hypervisor to add the device, a better way to put the above message would be

if not "OK domain" in add_output:
raise error.TestFail("Hypervisor command to add device '%s'failed."
"Output: %s" % (pci_add_cmd, add_output))

Quoted 5 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 654

Quoted 5 lines
client/tests/kvm/kvm_tests.py +4 -0
+    # compare the output of 'info pci'
+    s, after_add = vm.send_monitor_cmd("info pci")
+    if after_add == info_pci_ref:
+        raise error.TestFail("No new pci device shown in 'info pci'")

Another suggestion:

raise error.TestFail("No new PCI device shown after executing "
"hypervisor command 'info pci'")

Quoted 6 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 660

Quoted 6 lines
client/tests/kvm/kvm_tests.py +5 -0
+    time.sleep(int(params.get("seconds_wait_for_device_install")))
+
+    o = session.get_command_output(ref_cmd)
+    if reference == o:
+        raise error.TestFail("No new device shown in cmd: %s" % ref_cmd)

I found useful to explain on which side of the check the test fail, 'hypervisor', or 'guest'

raise error.TestFail("No new device shown on guest command %s output" %
ref_cmd)

Quoted 6 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 666

Quoted 6 lines
client/tests/kvm/kvm_tests.py +5 -0
+    cmd = params.get("find_pci_cmd")
+    output = session.get_command_output(cmd)
+    if not params.get("match_string") in output:
+        raise error.TestFail("Not found pci model: %s; Command is: %s" %
+                                                    (tested_model, cmd))

raise error.TestFail("PCI device model '%s' not found on host "
"command '%s' ouput" % (tested_model, cmd))

Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 674

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    # del pci device
+    slot_id = "0" + add_output.split(",")[2].split()[1]
+    cmd = "pci_del pci_addr=%s" % slot_id
+    s, after_del = vm.send_monitor_cmd(cmd)
+    if after_del == after_add:
+        raise error.TestFail("Failed to hot remove pci device:%s; Command:%s" %
+                                                     (tested_model, cmd))

raise error.TestFail("Failed to hot remove pci device '%s'. "
"Hypervisor command: '%s'" % (tested_model, cmd))

Hot remove doesn't work for me either... Since we are here, I still didn't understand why we do a hot remove of a device and right below it we try to verify if the newly added devices are working properly. Shouldn't be the other way around (ie checking and then hot removing)?

Quoted 20 lines
Quoted 20 lines
client/tests/kvm/kvm_tests.py +6 -0
+    # check whether VM's network&    disk work fine
+    if session.get_command_status(params.get("pci_test_cmd")):
+        raise error.TestFail("Check for %s device failed after PCI hotplug" %
+                                                                 test_type)
+
+    session.close()
client/tests/kvm/kvm_vm.py +2 -0
index 503f636..95b55eb 100644
@@ -239,6 +239,8 @@ class VM:
 
           for image_name in kvm_utils.get_sub_dict_names(params, "images"):
               image_params = kvm_utils.get_sub_dict(params, image_name)
+            if image_params.get("boot_drive") == "no":
+                continue
               qemu_cmd += " -drive file=%s" % get_image_filename(image_params,
                                                                  image_dir)
               if image_params.get("drive_format"):
Signature · 2 lines
Yolkfull
Regards,
#4 lore raw
In reply to Lucas Meneghel Rodrigues
Quoted 44 lines · Lucas Meneghel Rodrigues

I've spent some time doing a second review and test of the code. During my tests:

* I found some problems with PCI hotplug itself and would like help
to figure out why things are not working as expected.
* Made suggestions regarding the phrasing of the error messages
thrown by the test. Mostly nipticking. Let me know if you think the new messages make sense.
* The order of the final test steps looks a bit weird to me

Comments follow.

Quoted 30 lines · Yolkfull Chow
Quoted 28 lines · Yolkfull Chow
---
   client/tests/kvm/kvm.py               |    1 +
   client/tests/kvm/kvm_tests.cfg.sample |   65 ++++++++++++++++++++++-
   client/tests/kvm/kvm_tests.py         |   94 +++++++++++++++++++++++++++++++++
   client/tests/kvm/kvm_vm.py            |    2 +
   4 files changed, 161 insertions(+), 1 deletions(-)
client/tests/kvm/kvm.py +1 -0
index b18b643..fc92e10 100644
@@ -55,6 +55,7 @@ class kvm(test.test):
                   "kvm_install":  test_routine("kvm_install", "run_kvm_install"),
                   "linux_s3":     test_routine("kvm_tests", "run_linux_s3"),
                   "stress_boot":  test_routine("kvm_tests", "run_stress_boot"),
+                "pci_hotplug":  test_routine("kvm_tests", "run_pci_hotplug"),
                   }
 
           # Make it possible to import modules from the test's bindir
client/tests/kvm/kvm_tests.cfg.sample +0 -0
index 2f864de..a9e16d6 100644
@@ -94,6 +94,53 @@ variants:
           max_vms = 5
           alive_test_cmd = ps aux
 
Quoted 11 lines
Quoted 8 lines

client/tests/kvm/kvm_tests.cfg.sample variants:

Quoted 8 lines
client/tests/kvm/kvm_tests.cfg.sample +7 -0
+
+    - nic_hotplug:
+        type = pci_hotplug
+        pci_type = nic
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
 

I tried block device hotplug, lspci doesn't show up the newly added devices. Already tried with F8 and F9. Any idea why?

It doesn't need to modprobe acpiphp on Fedora, also, both F8 and F9
don't have virtio & virtio_ring modules. I ran it on guest Fedora-11 and Win2008, both ran successfully:

# ./scan_results.py
test                                                    status    seconds    info
----                                                    ------    -------    ----
Fedora.11.32.nic_hotplug.nic_rtl8139                            GOOD    68    completed successfully
Fedora.11.32.nic_hotplug.nic_virtio                     GOOD    46    completed successfully
Fedora.11.32.block_hotplug.fmt_qcow2.block_virtio        GOOD    46    completed successfully
Fedora.11.32.block_hotplug.fmt_qcow2.block_scsi         GOOD    44    completed successfully
Fedora.11.32.block_hotplug.fmt_raw.block_virtio         GOOD    45    completed successfully
Fedora.11.32.block_hotplug.fmt_raw.block_scsi           GOOD    46    completed successfully
Win2008.32.nic_hotplug.nic_rtl8139                              GOOD    66    completed successfully
Win2008.32.block_hotplug.fmt_qcow2.block_scsi           GOOD    186    completed successfully
Win2008.32.block_hotplug.fmt_raw.block_scsi             GOOD    71    completed successfully
Quoted 103 lines
Quoted 14 lines
Quoted 4 lines
client/tests/kvm/kvm_tests.cfg.sample +3 -0
+        pci_test_cmd = 'nslookupwww.redhat.com'
+        seconds_wait_for_device_install = 3
+        variants:

client/tests/kvm/kvm_tests.cfg.sample variants:

Quoted 10 lines
client/tests/kvm/kvm_tests.cfg.sample +9 -0
+            - @nic_8139:
+                pci_model = rtl8139
+                match_string = "8139"
+            - nic_virtio:
+                pci_model = virtio
+                match_string = "Virtio network device"
+            - nic_e1000:
+                pci_model = e1000
+                match_string = "Gigabit Ethernet Controller"
 

Pretty much all block hotplug 'guest side check' is failing during the stage where the output of lspci | tail -n1 is being compared with the match strings. Hypervisor is qemu 0.10.5 (kvm-87 upstream).

Quoted 74 lines
Quoted 42 lines
client/tests/kvm/kvm_tests.cfg.sample +35 -0
+    - block_hotplug:
+        type = pci_hotplug
+        pci_type = block
+        modprobe_acpiphp = yes
+        reference_cmd = lspci
+        find_pci_cmd = 'lspci | tail -n1'
+        images += " stg"
+        boot_drive_stg = no
+        image_name_stg = storage
+        image_size = 1G
+        force_create_image_stg = yes
+        pci_test_cmd = 'dir'
+        seconds_wait_for_device_install = 3
+        variants:
+            - block_virtio:
+                pci_model = virtio
+                match_string = "Virtio block device"
+            - block_scsi:
+                pci_model = scsi
+                match_string = "SCSI storage controller"
+        variants:
+            - fmt_qcow2:
+                image_format_stg = qcow2
+            - fmt_raw:
+                image_format_stg = raw
+
+
   # NICs
   variants:
       - @rtl8139:
@@ -306,6 +353,22 @@ variants:
               migration_test_command = ver&&    vol
           stress_boot:
               alive_test_cmd = systeminfo
+        nic_hotplug:
+            modprobe_acpiphp = no
+            reference_cmd = systeminfo
+            seconds_wait_for_device_install = 10
+            find_pci_cmd = ipconfig /all | find "Description"
+            nic_e1000:
+                match_string = "Intel(R) PRO/1000 MT Network Connection"
+        block_hotplug:

client/tests/kvm/kvm_tests.cfg.sample variants: · line 373

Quoted 10 lines
client/tests/kvm/kvm_tests.cfg.sample +8 -0
+            use_telnet = yes
+            modprobe_acpiphp = no
+            reference_cmd = wmic diskdrive
+            find_pci_cmd = wmic diskdrive | find "disk drives"
+            seconds_wait_for_device_install = 10
+            only block_scsi
+            block_scsi:
+                match_string = "SCSI"
 
 

It supports Windows block_hotplug now. But we need use_telnet to login Windows OS since command 'wmic' could only run on telnet session.

Quoted 19 lines
client/tests/kvm/kvm_tests.cfg.sample +0 -0
           variants:

- Win2000:

client/tests/kvm/kvm_tests.cfg.sample +1 -1
@@ -571,4 +634,4 @@ variants:
           only rtl8139
 
   # Choose your test list
-only fc8_quick
+#only fc8_quick
client/tests/kvm/kvm_tests.py +3 -0
index 2d11fed..230385a 100644
@@ -585,3 +585,97 @@ def run_stress_boot(tests, params, env):
           for se in sessions:
               se.close()
           logging.info("Total number booted: %d" % (num -1))
+
+
+def run_pci_hotplug(test, params, env):
Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 597

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    """
+    Test pci devices' hotplug
+    1) pci_add a deivce (nic or storage)
+    2) Compare 'info pci' output
+    3) Compare $reference_cmd output
+    4) Verify whether pci_model is shown in $pci_find_cmd
+    5) pci_del the device, verify whether could remove the pci device

What about if the last steps were

Quoted 2 lines

5) Verify if the newly added devices are working properly

Had worked out how to verify the newly added block device. Will send it here right now. Any suggestion about how to verify newly added nic card ? So far I just keep
'nslookup www.redhat.com' to check network simply.

Quoted 124 lines

6) pci_del the device, verify whether could remove the pci device

6) is already happening in the code, but in reverse order than mentioned above.

Quoted 31 lines
Quoted 31 lines
client/tests/kvm/kvm_tests.py +31 -0
+    @param test:   kvm test object
+    @param params: Dictionary with the test parameters
+    @param env:    Dictionary with test environment.
+    """
+    vm = kvm_utils.env_get_vm(env, params.get("main_vm"))
+    if not vm:
+        raise error.TestError("VM object not found in environment")
+    if not vm.is_alive():
+        raise error.TestError("VM seems to be dead; Test requires a living VM")
+
+    logging.info("Waiting for guest to be up...")
+
+    session = kvm_utils.wait_for(vm.ssh_login, 240, 0, 2)
+    if not session:
+        raise error.TestFail("Could not log into guest")
+
+    logging.info("Logged in")
+
+    # modprobe the module that enable hotplug
+    if params.get("modprobe_acpiphp") == "yes":
+        if session.get_command_status("modprobe acpiphp"):
+            raise error.TestError("Modprobe module 'acpiphp' failed")
+
+    # get reference output
+    s, info_pci_ref = vm.send_monitor_cmd("info pci")
+
+    # compare the output of `reference_cmd`
+    ref_cmd = params.get("reference_cmd")
+    reference = session.get_command_output(ref_cmd)
+
+    # implement pci hotplug
Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 636

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    tested_model = params.get("pci_model")
+    logging.info("Testing hotplug pci device:%s" % tested_model)
+
+    test_type = params.get("pci_type")
+    if test_type == "nic":
+        pci_add_cmd = "pci_add pci_addr=auto nic model=%s" % tested_model
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)

The command

s, add_output = vm.send_monitor_cmd(pci_add_cmd)

Can be moved out the if blocks since it will be executed in both paths, we save one line of code with this (and it's cleaner anyway).

Quoted 9 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 645

Quoted 9 lines
client/tests/kvm/kvm_tests.py +8 -0
+    elif test_type == "block":
+        image_name = params.get("image_name_stg")
+        image_format = params.get("image_format_stg", "qcow2")
+        image_filename = "%s.%s" % (image_name, image_format)
+        image_dir = os.path.join(test.bindir, "images")
+        storage_name = os.path.join(image_dir, image_filename)
+        pci_add_cmd = "pci_add pci_addr=auto storage file=%s,if=%s" % \
+                                              (storage_name, tested_model)

The above line would be better with implicit line continuation

pci_add_cmd = ("pci_add pci_addr=auto storage file=%s,if=%s" %
(storage_name, tested_model))

Quoted 5 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 649

Quoted 5 lines
client/tests/kvm/kvm_tests.py +4 -0
+        s, add_output = vm.send_monitor_cmd(pci_add_cmd)
+
+    if not "OK domain" in add_output:
+        raise error.TestFail("Command failed: %s" % pci_add_cmd)

Since we're executing a command on the hypervisor to add the device, a better way to put the above message would be

if not "OK domain" in add_output:
raise error.TestFail("Hypervisor command to add device '%s'failed."
"Output: %s" % (pci_add_cmd, add_output))

Quoted 5 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 654

Quoted 5 lines
client/tests/kvm/kvm_tests.py +4 -0
+    # compare the output of 'info pci'
+    s, after_add = vm.send_monitor_cmd("info pci")
+    if after_add == info_pci_ref:
+        raise error.TestFail("No new pci device shown in 'info pci'")

Another suggestion:

raise error.TestFail("No new PCI device shown after executing "
"hypervisor command 'info pci'")

Quoted 6 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 660

Quoted 6 lines
client/tests/kvm/kvm_tests.py +5 -0
+    time.sleep(int(params.get("seconds_wait_for_device_install")))
+
+    o = session.get_command_output(ref_cmd)
+    if reference == o:
+        raise error.TestFail("No new device shown in cmd: %s" % ref_cmd)

I found useful to explain on which side of the check the test fail, 'hypervisor', or 'guest'

raise error.TestFail("No new device shown on guest command %s output" %
ref_cmd)

Quoted 6 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 666

Quoted 6 lines
client/tests/kvm/kvm_tests.py +5 -0
+    cmd = params.get("find_pci_cmd")
+    output = session.get_command_output(cmd)
+    if not params.get("match_string") in output:
+        raise error.TestFail("Not found pci model: %s; Command is: %s" %
+                                                    (tested_model, cmd))

raise error.TestFail("PCI device model '%s' not found on host "
"command '%s' ouput" % (tested_model, cmd))

Quoted 8 lines

client/tests/kvm/kvm_tests.py def run_stress_boot(tests, params, env): · line 674

Quoted 8 lines
client/tests/kvm/kvm_tests.py +7 -0
+    # del pci device
+    slot_id = "0" + add_output.split(",")[2].split()[1]
+    cmd = "pci_del pci_addr=%s" % slot_id
+    s, after_del = vm.send_monitor_cmd(cmd)
+    if after_del == after_add:
+        raise error.TestFail("Failed to hot remove pci device:%s; Command:%s" %
+                                                     (tested_model, cmd))
Quoted 8 lines

raise error.TestFail("Failed to hot remove pci device '%s'. "
"Hypervisor command: '%s'" % (tested_model, cmd))

Hot remove doesn't work for me either... Since we are here, I still didn't understand why we do a hot remove of a device and right below it we try to verify if the newly added devices are working properly. Shouldn't be the other way around (ie checking and then hot removing)?

It did actually not verify the newly added device but simply verify if pci_del bring in any problem to the guest (disk or network). Since sometimes I found pci_del a nic card can break the guest's network as tested in our internal kvm version.

Quoted 21 lines
Quoted 21 lines
Quoted 21 lines
client/tests/kvm/kvm_tests.py +6 -0
+    # check whether VM's network&    disk work fine
+    if session.get_command_status(params.get("pci_test_cmd")):
+        raise error.TestFail("Check for %s device failed after PCI hotplug" %
+                                                                 test_type)
+
+    session.close()
client/tests/kvm/kvm_vm.py +2 -0
index 503f636..95b55eb 100644
@@ -239,6 +239,8 @@ class VM:
 
           for image_name in kvm_utils.get_sub_dict_names(params, "images"):
               image_params = kvm_utils.get_sub_dict(params, image_name)
+            if image_params.get("boot_drive") == "no":
+                continue
               qemu_cmd += " -drive file=%s" % get_image_filename(image_params,
                                                                  image_dir)
               if image_params.get("drive_format"):
Signature · 2 lines
Yolkfull
Regards,