Relocating u-boot console
Hello
Is it possible to relocate the u-boot console depending on the state of some GPIO pins (e.g. in board_init or board_late_init)? Currently I have the following serial configuration for my board:
#define CONFIG_SERIAL_MULTI
#define CONFIG_SYS_NS16550
#define CONFIG_SYS_NS16550_SERIAL
#define CONFIG_SYS_NS16550_REG_SIZE (-4)
#define CONFIG_SYS_NS16550_CLK CONFIG_JADE_IOCLK
#define CONFIG_SYS_NS16550_COM1 0xfffe1000
#define CONFIG_SYS_NS16550_COM2 0xfff50000
#define CONFIG_SYS_NS16550_COM3 0xfff51000
#define CONFIG_SYS_NS16550_COM4 0xfff43000
#define CONFIG_CONS_INDEX 4
This results in a console on COM4. Now I would like to have the console on COM1 under some circumstances for maintanance reasons.
Regards,
Matthias Wei?er
Quoted 15 lines · On Wednesday 14 October 2009 09:47:27 Matthias Wei?er wrote:
Is it possible to relocate the u-boot console depending on the state of some GPIO pins (e.g. in
board_initorboard_late_init)? Currently I have the following serial configuration for my board:#define
CONFIG_SERIAL_MULTI
#defineCONFIG_SYS_NS16550
#defineCONFIG_SYS_NS16550_SERIAL
#defineCONFIG_SYS_NS16550_REG_SIZE(-4)
#defineCONFIG_SYS_NS16550_CLKCONFIG_JADE_IOCLK
#defineCONFIG_SYS_NS16550_COM10xfffe1000
#defineCONFIG_SYS_NS16550_COM20xfff50000
#defineCONFIG_SYS_NS16550_COM30xfff51000
#defineCONFIG_SYS_NS16550_COM40xfff43000
#defineCONFIG_CONS_INDEX4
Quoted 2 lines
This results in a console on COM4. Now I would like to have the console on COM1 under some circumstances for maintanance reasons.
if your devices fit into the stdio framework, simply change the std{err,in,out} env vars in your board code
-mike
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: application/pgp-signature
Size: 836 bytes
Desc: This is a digitally signed message part.
Url : http://lists.denx.de/pipermail/u-boot/attachments/20091014/d53f5e76/attachment.pgp
Quoted 6 lines · Mike Frysinger
Quoted 2 lines · On Wednesday 14 October 2009 09:47:27 Matthias Wei?er wrote:
This results in a console on COM4. Now I would like to have the console on COM1 under some circumstances for maintanance reasons.
if your devices fit into the stdio framework, simply change the std{err,in,out} env vars in your board code
Ah. OK. That guided me into the right direction. To redirect the console to another serial port I had to set std{err,in,out} to eserialn.
Thanks,
Matthias