Fix blktap2 test in xen-hotplug-cleanup
PATCH 1/1 Fix blktap2 test in xen-hotplug-cleanup
The blktap2 test in xen-hotplug-cleanup was not quite right, causing orphaned /vm/<uuid>/device node in xenstore. Attempt to reattach the device failed:
xen53: # xm block-attach 0 file:/tmp/d0 /dev/xvdp r
xen53: # xm block-detach 0 /dev/xvdp
xen53: # xenstore-ls /vm/00000000-0000-0000-0000-000000000000/device vbd = ""
51952 = ""
frontend = "/local/domain/0/device/vbd/51952"
frontend-id = "0"
backend-id = "0"
backend = "/local/domain/0/backend/vbd/0/51952"
xen53: # xm block-attach 0 file:/tmp/d0 /dev/xvdp r
Error: Device /dev/xvdp (51952, vbd) is already connected.
Usage: xm block-attach <Domain> <BackDev> <FrontDev> <Mode> [BackDomain]
Attached patch fixes the test.
Regards,
Jim
tools/hotplug/Linux/xen-hotplug-cleanup +1 -1
@@ -21,7 +21,7 @@ if [ "$vm" != "" ]; then # if the vm path does not exist and the device class is 'vbd' then we may have # a tap2 device - if [ ! $(xenstore-read "vm_dev" 2>/dev/null) ] \ + if [ $(xenstore-read "$vm_dev" 2>/dev/null) != "" ] \ && [ "${path_array[1]}" = "vbd" ]; then vm_dev="$vm/device/tap2/${path_array[3]}" fi
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xensource.com/xen-devel