staging: comedi - correct parameter gainlkup for DAQCard-6024E in driver ni_mio_cs.c

PATCH New Martin Homuth-Rosemann 1 participant 1 message May 31, 2010 Staging

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 staging: comedi - correct parameter gainlkup for DAQCard-6024E in driver ni_mio_cs.c

From: Martin Homuth-Rosemann <[email protected]>

Correct at least one of the incorrect specs for a national instrument data acquisition card DAQCard-6024E. This card has only four different gain settings (+-10V, +-5V, +-0.5V, +-0.05V).

---

drivers/staging/comedi/drivers/ni_mio_cs.c 2010-05-27 12:26:22.000000000 +0200 renamed from drivers/staging/comedi/drivers/ni_mio_cs.c.orig 2010-02-24 19:52:17.000000000 +0100 +1 -1
@@ -121,11 +121,11 @@ static const struct ni_board_struct ni_b
      .name = "DAQCard-6024E",    /* specs incorrect! */
      .n_adchan = 16,
      .adbits = 12,
      .ai_fifo_depth = 1024,
      .alwaysdither = 0,
-     .gainlkup = ai_gain_16,
+     .gainlkup = ai_gain_4,
      .ai_speed = 5000,
      .n_aochan = 2,
      .aobits = 12,
      .ao_fifo_depth = 0,
      .ao_range_table = &range_bipolar10,