Skip to contentSkip to conversation

ib0: failed send event

DISCUSSION Craig Prescott 2 participants 2 messages Nov 4, 2010 – Nov 10, 2010 1 message not in the archive InfiniBand

lore
Share & tools
lore
#0 lore raw

Hi,

We have a new-ish node whose IPoIB access was interrupted last night; last message in the syslog was:

ib0: failed send event (status=2, wrid=74 vend_err 67)

The node has a Mellanox ConnectX HCA (MHQH19-XTC).

I understand the status corresponds to IB_WC_LOC_QP_OP_ERR. What does a vendor error code of 67 mean?

Thanks,
Craig Prescott
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html

A message that is not in the archive (sent off-list or not yet received): [email protected]

#2 lore raw
Quoted 12 lines · Craig Prescott

Hi,

We have a new-ish node whose IPoIB access was interrupted last night; last message in the syslog was:

ib0: failed send event (status=2, wrid=74 vend_err 67)

The node has a Mellanox ConnectX HCA (MHQH19-XTC).

I understand the status corresponds to IB_WC_LOC_QP_OP_ERR. What does a vendor error code of 67 mean?

Quoted 6 lines

Thanks,
Craig Prescott
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html

Error is: Bus error reading WQE.

Tziporet
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html