net: use NETIF_F_ALL_TSO for vlan features
Subsystems (2)
PATCH 1/2 net: use NETIF_F_ALL_TSO for vlan features
As Dimitris Michailidis suggested, use NETIF_F_ALL_TSO for vlan_features, which is a mask, but not hw_features.
Compile test.
--- drivers/net/bnx2x/bnx2x_main.c | 2 +- drivers/net/cxgb4/cxgb4_main.c | 2 +- drivers/net/cxgb4vf/cxgb4vf_main.c | 2 +- 3 files changed, 3 insertions(+), 3 deletions(-)
drivers/net/bnx2x/bnx2x_main.c +1 -1
@@ -9429,7 +9429,7 @@ static int __devinit bnx2x_init_dev(struct pci_dev *pdev,NETIF_F_RXCSUM |NETIF_F_LRO |NETIF_F_HW_VLAN_TX ; dev->vlan_features =NETIF_F_SG |NETIF_F_IP_CSUM |NETIF_F_IPV6_CSUM | -NETIF_F_TSO |NETIF_F_TSO_ECN |NETIF_F_TSO6 |NETIF_F_HIGHDMA ; +NETIF_F_ALL_TSO |NETIF_F_HIGHDMA ; dev->features |= dev->hw_features |NETIF_F_HW_VLAN_RX ;if (bp->flags &USING_DAC_FLAG )
drivers/net/cxgb4/cxgb4_main.c +1 -1
@@ -3526,7 +3526,7 @@ static void free_some_resources(struct adapter *adapter) }#define TSO_FLAGS (NETIF_F_TSO | NETIF_F_TSO6 | NETIF_F_TSO_ECN) -#define VLAN_FEAT (NETIF_F_SG | NETIF_F_IP_CSUM | TSO_FLAGS | \ +#define VLAN_FEAT (NETIF_F_SG | NETIF_F_IP_CSUM | NETIF_F_ALL_TSO | \ NETIF_F_IPV6_CSUM | NETIF_F_HIGHDMA) static int __devinit init_one(struct pci_dev *pdev,
drivers/net/cxgb4vf/cxgb4vf_main.c +1 -1
@@ -2603,7 +2603,7 @@ static int __devinit cxgb4vf_pci_probe(struct pci_dev *pdev, netdev->hw_features =NETIF_F_SG |TSO_FLAGS |NETIF_F_IP_CSUM |NETIF_F_IPV6_CSUM |NETIF_F_HW_VLAN_TX |NETIF_F_RXCSUM ; - netdev->vlan_features =NETIF_F_SG |TSO_FLAGS | + netdev->vlan_features =NETIF_F_SG |NETIF_F_ALL_TSO |NETIF_F_IP_CSUM |NETIF_F_IPV6_CSUM |NETIF_F_HIGHDMA ; netdev->features = netdev->hw_features |
Signature · 1 line
1.7.3.1
David Miller
maintainerFrom: Shan Wei <[email protected]>
Date: Fri, 29 Apr 2011 13:20:52 +0800
Quoted 8 lines
As Dimitris Michailidis suggested, use
NETIF_F_ALL_TSOforvlan_features, which is a mask, but nothw_features.Compile test.
Signed-off-by Shan Wei <[email protected]>
I do not understand why we want to advertise a set of ->vlan_features TSO flags that are different from the flags advertised in ->hw_features.
Why do we want to do this?
2011/5/5 David Miller <[email protected]>:
Quoted 8 lines
From: Shan Wei <[email protected]>
Date: Fri, 29 Apr 2011 13:20:52 +0800Quoted 2 lines
As Dimitris Michailidis suggested, use
NETIF_F_ALL_TSOforvlan_features, which is a mask, but nothw_features.I do not understand why we want to advertise a set of ->vlan_features TSO flags that are different from the flags advertised in ->hw_features.
Why do we want to do this?
I remember some posts about hardware that needs HW tag insertion for TSO on VLAN to work or other additional constraints for offloads on VLANs. I wonder if vlan_features handling should be converted to something like ndo_fix_features.
Best Regards,
Michał Mirosław