error when doing passthrough of bcm netextreme II 10 G device
Hi Folks :
I am trying to assinga bcm netextreme II 10 G eth device to a guest using PCI passthrough in QEMU.
01:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM57711 10-Gigabit PCIe
01:00.1 Ethernet controller: Broadcom Corporation NetXtreme II BCM57711 10-Gigabit PCIe
qemu> device_add pci-assign,host=01:00.0,id=e10g
The device shows up in the guest but the driver is enable to attach to it :
bnx2x 0000:00:05.0: PCI INT A -> Link[LNKA] -> GSI 10 (level, high) -> IRQ 10
bnx2x 0000:00:05.0: setting latency timer to 64
bnx2x: Cannot find power management capability, aborting
bnx2x 0000:00:05.0: PCI INT A disabled
bnx2x: probe of 0000:00:05.0 failed with error -5
As you can see, it errs with EIO (-5). Any ideas why this might be the case? I am using 2.6.34.6 in the host, 2.6.27.39 in the guest and qemu 0.12.4 :
qemu-system-x86_64 --help
QEMU PC emulator version 0.12.4 (qemu-kvm-0.12.4), Copyright (c) 2003-2008 Fabrice Bellard
Thanks in advance for the help,
Ani.
============================================================
The information contained in this message may be privileged and confidential and protected from disclosure. If the reader of this message is not the intended recipient, or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any reproduction, dissemination or distribution of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by replying to the message and deleting it from your computer. Thank you. Tellabs
============================================================
Quoted 25 lines · Ani
Hi Folks :
I am trying to assinga bcm netextreme II 10 G eth device to a guest using PCI passthrough in QEMU.
01:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM57711 10-Gigabit PCIe
01:00.1 Ethernet controller: Broadcom Corporation NetXtreme II BCM57711 10-Gigabit PCIeqemu>
device_addpci-assign,host=01:00.0,id=e10gThe device shows up in the guest but the driver is enable to attach to it :
bnx2x 0000:00:05.0: PCI INT A -> Link[LNKA] -> GSI 10 (level, high) -> IRQ 10
bnx2x 0000:00:05.0: setting latency timer to 64
bnx2x: Cannot find power management capability, aborting
bnx2x 0000:00:05.0: PCI INT A disabled
bnx2x: probe of 0000:00:05.0 failed with error -5
Quoted 3 lines
As you can see, it errs with EIO (-5). Any ideas why this might be the case? I am using 2.6.34.6 in the host, 2.6.27.39 in the guest and qemu 0.12.4 :
You should retry with qemu-kvm >= 0.14.
Jan
Signature · 2 lines
Siemens AG, Corporate Technology, CT T DE IT 1 Corporate Competence Center Embedded Linux