Skip to contentSkip to conversation

crushmap errors

DISCUSSION Martin Mailand 3 participants 4 messages Nov 11, 2011 – Nov 14, 2011

lore
Share & tools
lore
#0 lore raw

Hi,
I used in ceph v0.38 the host and rack feature in the conf during an mkcephfs. Now I have to problems with the crushmap

1. I cannot compile a ceph genearated crushmap.
crushtool -c file.txt -o file
file.txt:4 error: parse error at '.0'

# begin crush map
# devices
device 0 osd.0

2. Why are 2 racks are not enough for 2 failure domains? From the commit:
If there are >2 racks, separate across racks.

and in the src/osd/OSDMap.cc

if (racks.size() > 3) {
// spread replicas across hosts crush_rule_set_step(rule, 1, CRUSH_RULE_CHOOSE_LEAF_FIRSTN,
CRUSH_CHOOSE_N, 2);

shouldn't that be

if (racks.size() > 1) {
// spread replicas across racks crush_rule_set_step(rule, 1, CRUSH_RULE_CHOOSE_LEAF_FIRSTN,
CRUSH_CHOOSE_N, 2);

Best Regards,
martin

#1 lore raw
Quoted 7 lines · Martin Mailand

Hi,
I used in ceph v0.38 the host and rack feature in the conf during an mkcephfs. Now I have to problems with the crushmap

1. I cannot compile a ceph genearated crushmap.
crushtool -c file.txt -o file
file.txt:4 error: parse error at '.0'

Whoops, will push a patch to stable shortly. The grammer wasn't recognizing '.' as a legal character.

Quoted 3 lines

2. Why are 2 racks are not enough for 2 failure domains? From the commit:
If there are >2 racks, separate across racks.

Well, technically they are. My worry is that it's more likely that racks will have significantly vary capacity (i.e. crush weight) due to, say, 1 full rack and a second 1/2 rack. If the policy forces replicas be placed across racks things won't balance well.

I suppose there should be an argument like --min-racks that controls that threshold?

sage

#2 lore raw

Hi Sage,
1. The crushtool grammer fix is working for me. Thanks.

2. I think if an admin puts the extra rack info into the ceph.conf file, than it should do what expected. I understand your worries but on the other end ceph is not an end user tool, and people should know what they do and balance there racks evenly. Just my two cents.

-martin

Am 11.11.2011 23:51, schrieb Sage Weil:

Quoted 29 lines · Martin Mailand
Quoted 7 lines

Hi,
I used in ceph v0.38 the host and rack feature in the conf during an mkcephfs. Now I have to problems with the crushmap

1. I cannot compile a ceph genearated crushmap.
crushtool -c file.txt -o file
file.txt:4 error: parse error at '.0'

Whoops, will push a patch to stable shortly. The grammer wasn't recognizing '.' as a legal character.

Quoted 3 lines

2. Why are 2 racks are not enough for 2 failure domains? From the commit:
If there are>2 racks, separate across racks.

Well, technically they are. My worry is that it's more likely that racks will have significantly vary capacity (i.e. crush weight) due to, say, 1 full rack and a second 1/2 rack. If the policy forces replicas be placed across racks things won't balance well.

I suppose there should be an argument like --min-racks that controls that threshold?

sage
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#3 lore raw
In reply to Sage Weil
Quoted 11 lines · Sage Weil
Quoted 3 lines

2. Why are 2 racks are not enough for 2 failure domains? From the commit:
If there are >2 racks, separate across racks.

Well, technically they are.  My worry is that it's more likely that racks will have significantly vary capacity (i.e. crush weight) due to, say, 1 full rack and a second 1/2 rack.  If the policy forces replicas be placed across racks things won't balance well.

I suppose there should be an argument like --min-racks that controls that threshold?

In theory the operator can shoot themselves in the foot if they so please. It seems like a Ceph management console could warn about "imbalanced crush weight" across racks. This would also allow the cluster operator to check on their balance over time assuming hardware gets replaced over time. This could introduce larger rotational hdds, or smaller ssds, across the cluster.

Kelly
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]