PATCH 2/3 mtip32xx: Fix to make lba address correct in big-endian systems

Earlier lba address was assigned directly to lba_low and lba_low_ex, which would result in a different number (bytes reversed) in big-endian systems. Now assigning lba address byte-by-byte to fis.

---
 drivers/block/mtip32xx/mtip32xx.c |    8 ++++++--
 1 files changed, 6 insertions(+), 2 deletions(-)
drivers/block/mtip32xx/mtip32xx.c +6 -2
index dfb7196..df46b5a 100644
@@ -2465,8 +2465,12 @@ static void mtip_hw_submit_io(struct driver_data *dd, sector_t start,
 	fis->opts        = 1 << 7;
 	fis->command     =
 		(dir == READ ? ATA_CMD_FPDMA_READ : ATA_CMD_FPDMA_WRITE);
-	*((unsigned int *) &fis->lba_low) = (start & 0xFFFFFF);
-	*((unsigned int *) &fis->lba_low_ex) = ((start >> 24) & 0xFFFFFF);
+	fis->lba_low     = start & 0xFF;
+	fis->lba_mid     = (start >> 8) & 0xFF;
+	fis->lba_hi      = (start >> 16) & 0xFF;
+	fis->lba_low_ex  = (start >> 24) & 0xFF;
+	fis->lba_mid_ex  = (start >> 32) & 0xFF;
+	fis->lba_hi_ex   = (start >> 40) & 0xFF;
 	fis->device	 = 1 << 6;
 	fis->features    = nsect & 0xFF;
 	fis->features_ex = (nsect >> 8) & 0xFF;