Hi guys,

I'm testing Ceph as storage for KVM virtual machine images and found an inconvenience that I am hoping it is possible to find the cause of.

I'm running a single KVM Linux guest on top of Ceph storage. In that guest I run rsync to download files from the internet. When rsync is running, the guest will seemingly stall and run very slowly.

For example if I log in via SSH to the guest and use the command prompt, nothing will happen for a long period (30+ seconds), then it processes a few typed characters, and then it blocks for another long period of time, then process a bit more, etc.

I was hoping to be able to tweak the system so that it runs more like when using conventional storage - i.e. perhaps the rsync won't be super fast, but the machine will be equally responsive all the time.

I'm hoping that you can provide some hints on how to best benchmark or test the system to find the cause of this?

The ceph OSDs periodically logs thse two messages, that I do not fully understand:

12-12-30 17:07:12.894920 7fc8f3242700 1 heartbeat_map is_healthy 'OSD::op_tp thread 0x7fc8cbfff700' had timed out after 30

2012-12-30 17:07:13.599126 7fc8cbfff700  1 heartbeat_map reset_timeout 'OSD::op_tp thread 0x7fc8cbfff700' had timed out after 30

Is this to be expected when the system is in use, or does it indicate that something is wrong?

Ceph also logs messages such as this:

2012-12-30 17:07:36.932272 osd.0 10.0.0.1:6800/9157 286340 : [WRN] slow request 30.751940 seconds old, received at 2012-12-30 17:07:06.180236: osd_op(client.4705.0:16074961 rb.0.11b7.4a933baa.0000000c188f [write 532480~4096] 0.f2a63fe) v4 currently waiting for sub ops

My setup:

3 servers running Fedora 17 with Ceph 0.55.1 from RPM.
Each server runs one osd and one mon. One of the servers also runs an mds.
Backing file system is btrfs stored on a md-raid . Journal is stored on the same SATA disks as the rests of the data. Each server has 3 bonded gigabit/sec NICs.

One server running Fedora 16 with qemu-kvm.
Has gigabit/sec NIC connected to the same network as the Ceph servers, and a gigabit/sec NIC connected to the Internet. Disk is mounted with:

-drive format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

iostat on the KVM guest gives:

avg-cpu: %user %nice %system %iowait %steal %idle

           0,00    0,00    0,00  100,00    0,00    0,00

Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz avgqu-sz await svctm %util
vda 0,00 1,40 0,10 0,30 0,80 13,60 36,00 1,66 2679,25 2499,75 99,99

Top on the KVM host shows 90% CPU idle and 0.0% I/O waiting.

iostat on a OSD gives:
avg-cpu: %user %nice %system %iowait %steal %idle

           0,13    0,00    1,50   15,79    0,00   82,58
Device:         rrqm/s   wrqm/s     r/s     w/s    rkB/s    wkB/s avgrq-sz avgqu-sz   await r_await w_await  svctm  %util
sda             240,70   441,20   33,00   42,70  1122,40  1961,80 81,48    14,45  164,42  319,14   44,85   6,63  50,22
sdb             299,10   393,10   33,90   38,40  1363,60  1720,60 85,32    13,55  171,32  316,21   43,41   6,55  47,39
sdc             268,50   441,60   28,80   45,40  1191,60  1977,00 85,41    19,08  159,39  345,98   41,02   6,56  48,69
sdd             255,50   445,50   30,20   45,00  1150,40  1975,80 83,14    18,18  155,97  338,90   33,20   6,95  52,23

md0 0,00 0,00 1,20 132,70 4,80 4086,40 61,11 0,00 0,00 0,00 0,00 0,00 0,00

The figures are similar on all three OSDs.

I am thinking that one possible cause could be that the journal is stored on the same disks as the rest of the data, but I don't know how to benchmark if this is actually the case (?)

Thanks for any help or advice, you can offer!

Signature · 7 lines
Jens Kristian Søgaard, Mermaid Consulting ApS,
[email protected],
http://www.mermaidconsulting.com/
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#1 lore raw
Quoted 87 lines · Jens Kristian Søgaard

Hi guys,

I'm testing Ceph as storage for KVM virtual machine images and found an inconvenience that I am hoping it is possible to find the cause of.

I'm running a single KVM Linux guest on top of Ceph storage. In that guest I run rsync to download files from the internet. When rsync is running, the guest will seemingly stall and run very slowly.

For example if I log in via SSH to the guest and use the command prompt, nothing will happen for a long period (30+ seconds), then it processes a few typed characters, and then it blocks for another long period of time, then process a bit more, etc.

I was hoping to be able to tweak the system so that it runs more like when using conventional storage - i.e. perhaps the rsync won't be super fast, but the machine will be equally responsive all the time.

I'm hoping that you can provide some hints on how to best benchmark or test the system to find the cause of this?

The ceph OSDs periodically logs thse two messages, that I do not fully understand:

12-12-30 17:07:12.894920 7fc8f3242700 1 heartbeat_map is_healthy 'OSD::op_tp thread 0x7fc8cbfff700' had timed out after 30

2012-12-30 17:07:13.599126 7fc8cbfff700  1 heartbeat_map reset_timeout

'OSD::op_tp thread 0x7fc8cbfff700' had timed out after 30

Is this to be expected when the system is in use, or does it indicate that something is wrong?

Ceph also logs messages such as this:

2012-12-30 17:07:36.932272 osd.0 10.0.0.1:6800/9157 286340 : [WRN] slow

request 30.751940 seconds old, received at 2012-12-30 17:07:06.180236:
osd_op(client.4705.0:16074961 rb.0.11b7.4a933baa.0000000c188f [write 532480~4096] 0.f2a63fe) v4 currently waiting for sub ops

My setup:

3 servers running Fedora 17 with Ceph 0.55.1 from RPM.
Each server runs one osd and one mon. One of the servers also runs an mds. Backing file system is btrfs stored on a md-raid . Journal is stored on the same SATA disks as the rests of the data.
Each server has 3 bonded gigabit/sec NICs.

One server running Fedora 16 with qemu-kvm.
Has gigabit/sec NIC connected to the same network as the Ceph servers, and a gigabit/sec NIC connected to the Internet.
Disk is mounted with:

-drive format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

iostat on the KVM guest gives:

avg-cpu: %user %nice %system %iowait %steal %idle

           0,00    0,00    0,00  100,00    0,00    0,00

Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s avgrq-sz
avgqu-sz await svctm %util
vda 0,00 1,40 0,10 0,30 0,80 13,60 36,00
1,66 2679,25 2499,75 99,99

Top on the KVM host shows 90% CPU idle and 0.0% I/O waiting.

iostat on a OSD gives:
avg-cpu: %user %nice %system %iowait %steal %idle

           0,13    0,00    1,50   15,79    0,00   82,58

Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz
avgqu-sz await r_await w_await svctm %util
sda 240,70 441,20 33,00 42,70 1122,40 1961,80 81,48
14,45 164,42 319,14 44,85 6,63 50,22
sdb 299,10 393,10 33,90 38,40 1363,60 1720,60 85,32
13,55 171,32 316,21 43,41 6,55 47,39
sdc 268,50 441,60 28,80 45,40 1191,60 1977,00 85,41
19,08 159,39 345,98 41,02 6,56 48,69
sdd 255,50 445,50 30,20 45,00 1150,40 1975,80 83,14
18,18 155,97 338,90 33,20 6,95 52,23
md0 0,00 0,00 1,20 132,70 4,80 4086,40 61,11
0,00 0,00 0,00 0,00 0,00 0,00

Quoted 7 lines

The figures are similar on all three OSDs.

I am thinking that one possible cause could be that the journal is stored on the same disks as the rest of the data, but I don't know how to benchmark if this is actually the case (?)

Thanks for any help or advice, you can offer!

Hi Jens,

You may try do play with SCHED_RT, I have found it hard to use for myself, but you can achieve your goal by adding small RT slices via ``cpu'' cgroup to vcpu/emulator threads, it dramatically increases overall VM` responsibility. I have thrown it off because RT scheduler is a very strange thing - it may cause endless lockup on disk operation during heavy operations or produce ever-stuck ``kworker'' on some cores if you have killed VM which has separate RT slices for vcpu threads. Of course, some Ceph tuning like writeback cache and large journal may help you too, Im speaking primarily of VM performance by itself.

Quoted 9 lines

--
Jens Kristian Søgaard, Mermaid Consulting ApS, [email protected],
http://www.mermaidconsulting.com/
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#2 lore raw

Hi Andrey,

Thanks for your reply!

Quoted 4 lines

You may try do play with SCHED_RT, I have found it hard to use for myself, but you can achieve your goal by adding small RT slices via ``cpu'' cgroup to vcpu/emulator threads, it dramatically increases overall VM` responsibility.

I'm not quite sure I understand your suggestion.

Do you mean that you set the process priority to real-time on each qemu-kvm process, and then use cgroups cpu.rt_runtime_us / cpu.rt_period_us to restrict the amount of CPU time those processes can receive?

I'm not sure how that would apply here, as I have only one qemu-kvm process and it is not non-responsive because of the lack of allocated CPU time slices - but rather because some I/Os take a long time to complete, and other I/Os apparently have to wait for those to complete.

Quoted 2 lines

threads. Of course, some Ceph tuning like writeback cache and large journal may help you too, Im speaking primarily of VM performance by

I have been considering the journal as something where I could improve performance by tweaking the setup. I have set aside 10 GB of space for the journal, but I'm not sure if this is too little - or if the size really doesn't matter that much when it is on the same mdraid as the data itself.

Is there a tool that can tell me how much of my journal space that is actually actively being used?

I.e. I'm looking for something that could tell me, if increasing the size of the journal or placing it on a seperate (SSD) disk could solve my problem.

How do I change the size of the writeback cache when using qemu-kvm like I do?

Does setting rbd cache size in ceph.conf have any effect on qemu-kvm, where the drive is defined as:

format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

Signature · 7 lines
Jens Kristian Søgaard, Mermaid Consulting ApS,
[email protected],
http://www.mermaidconsulting.com/
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#3 lore raw
Quoted 13 lines · Jens Kristian Søgaard

Hi Andrey,

Thanks for your reply!

Quoted 4 lines

You may try do play with SCHED_RT, I have found it hard to use for myself, but you can achieve your goal by adding small RT slices via ``cpu'' cgroup to vcpu/emulator threads, it dramatically increases overall VM` responsibility.

I'm not quite sure I understand your suggestion.

Quoted 9 lines

Do you mean that you set the process priority to real-time on each qemu-kvm process, and then use cgroups cpu.rt_runtime_us / cpu.rt_period_us to restrict the amount of CPU time those processes can receive?

I'm not sure how that would apply here, as I have only one qemu-kvm process and it is not non-responsive because of the lack of allocated CPU time slices - but rather because some I/Os take a long time to complete, and other I/Os apparently have to wait for those to complete.

Yep, I meant the same. Of course it`ll not help with only one VM, RT may help in more concurrent cases :)

Quoted 10 lines
Quoted 3 lines

threads. Of course, some Ceph tuning like writeback cache and large journal may help you too, Im speaking primarily of VM performance by

I have been considering the journal as something where I could improve performance by tweaking the setup. I have set aside 10 GB of space for the journal, but I'm not sure if this is too little - or if the size really doesn't matter that much when it is on the same mdraid as the data itself.

Quoted 5 lines

Is there a tool that can tell me how much of my journal space that is actually actively being used?

I.e. I'm looking for something that could tell me, if increasing the size of the journal or placing it on a seperate (SSD) disk could solve my problem.

As I understood right, you have md device holding both journal and filestore? What type of raid you have here? Of course you`ll need a separate device (for experimental purposes, fast disk may be enough) for the journal, and if you set any type of redundant storage under filestore partition, you may also change it to simple RAID0, or even separate disks, and create one osd over every disk(you should see to the journal device` throughput which must be equal to sum of speeds of all filestore devices, so for commodity-type SSD it sums to two 100MB/s disks, for example). I have ``pure'' disk setup in my dev environment built on quite old desktop-class machines and one rsync process may hang VM for short time, despite of using dedicated SATA disk for journal.

Quoted 9 lines

How do I change the size of the writeback cache when using qemu-kvm like I do?

Does setting rbd cache size in ceph.conf have any effect on qemu-kvm, where the drive is defined as:

format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

What size of cache_size/max_dirty you have inside ceph.conf and which qemu version you use? Default values good enough to prevent pushing I/O spikes down to the physical storage, but for long I/O-intensive tasks increasing cache may help OS to align writes more smoothly. Also you don`t need to set rbd_cache explicitly in the disk config using qemu 1.2 and younger releases, for older ones
http://lists.gnu.org/archive/html/qemu-devel/2012-05/msg02500.html
should be applied.

Quoted 5 lines

--
Jens Kristian Søgaard, Mermaid Consulting ApS,
[email protected],
http://www.mermaidconsulting.com/

--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#4 lore raw

Hi Andrey,

Quoted 2 lines

As I understood right, you have md device holding both journal and filestore? What type of raid you have here?

Yes, same md device holding both journal and filestore. It is a raid5.

Quoted 3 lines

Of course you`ll need a
separate device (for experimental purposes, fast disk may be enough) for the journal

Is there a way to tell if the journal is the bottleneck without actually
adding such an extra device?

Quoted 2 lines

filestore partition, you may also change it to simple RAID0, or even separate disks, and create one osd over every disk(you should see to

I have only 3 OSDs with 4 disks each. I was afraid that it would be too brittle as a RAID0, and if I created seperate OSDs for each disk, it would stall the file system due to recovery if a server crashes.

Quoted 1 line

What size of cache_size/max_dirty you have inside ceph.conf

I haven't set them explicitly, so I imagine the cache_size is 32 MB and the max_dirty is 24 MB.

Quoted 2 lines

and which
qemu version you use?

Using the default 0.15 version in Fedora 16.

Quoted 5 lines

tasks increasing cache may help OS to align writes more smoothly. Also you don`t need to set rbd_cache explicitly in the disk config using qemu 1.2 and younger releases, for older ones
http://lists.gnu.org/archive/html/qemu-devel/2012-05/msg02500.html
should be applied.

I read somewhere that I needed to enable it specifically for older qemu-kvm versions, which I did like this:

format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

However now I read in the docs for qemu-rbd that it needs to be set like this:

format=raw,file=rbd:data/squeeze:rbd_cache=true,cache=writeback

I'm not sure if 1 and true are interpreted the same way?

I'll try using "true" and see if I get any noticable changes in behaviour.

The link you sent me seems to indicate that I need to compile my own version of qemu-kvm to be able to test this?

Signature · 7 lines
Jens Kristian Søgaard, Mermaid Consulting ApS,
[email protected],
http://www.mermaidconsulting.com/
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
#5 lore raw
Quoted 8 lines · Jens Kristian Søgaard

Hi Andrey,

Quoted 2 lines

As I understood right, you have md device holding both journal and filestore? What type of raid you have here?

Yes, same md device holding both journal and filestore. It is a raid5.

Ahem, of course you need to reassemble it to something faster :)

Quoted 10 lines
Quoted 5 lines

Of course you`ll need a
separate device (for experimental purposes, fast disk may be enough) for the journal

Is there a way to tell if the journal is the bottleneck without actually adding such an extra device?

In theory, yes - but your setup already dying under high amount of write seeks, so it may be not necessary. Also I don`t see a right way to measure a bottleneck when disk device used for both filestore and journal - in case of separated ones, you may measure maximum values using fio and compare to calculated ones from /proc/diskstats, ``all-in-one'' case seems obviously hard to measure, even if you able to log writes to journal file and filestore files separately without significant overhead.

Quoted 8 lines
Quoted 3 lines

filestore partition, you may also change it to simple RAID0, or even separate disks, and create one osd over every disk(you should see to

I have only 3 OSDs with 4 disks each. I was afraid that it would be too brittle as a RAID0, and if I created seperate OSDs for each disk, it would stall the file system due to recovery if a server crashes.

No, it isn`t too bad in most cases. Recovery process is not affecting operations to the rbd storage except small performance degradation, so you may split your raid setup to the lightweight R0. It depends, on plain SATA controller software R0 under one OSD will do better work than >2 separate OSDs having one disk each, on cache-backed controller separate OSDs is more preferably until controller is not able to align writes due to overall write bandwidth.

Quoted 32 lines
Quoted 3 lines

What size of cache_size/max_dirty you have inside ceph.conf

I haven't set them explicitly, so I imagine the cache_size is 32 MB and the max_dirty is 24 MB.

Quoted 3 lines

and which

qemu version you use?

Using the default 0.15 version in Fedora 16.

Quoted 5 lines

tasks increasing cache may help OS to align writes more smoothly. Also you don`t need to set rbd_cache explicitly in the disk config using qemu 1.2 and younger releases, for older ones
http://lists.gnu.org/archive/html/qemu-devel/2012-05/msg02500.html
should be applied.

I read somewhere that I needed to enable it specifically for older qemu-kvm versions, which I did like this:

format=rbd,file=rbd:data/image1:rbd_cache=1,if=virtio

However now I read in the docs for qemu-rbd that it needs to be set like this:

Quoted 9 lines

format=raw,file=rbd:data/squeeze:rbd_cache=true,cache=writeback

I'm not sure if 1 and true are interpreted the same way?

I'll try using "true" and see if I get any noticable changes in behaviour.

The link you sent me seems to indicate that I need to compile my own version of qemu-kvm to be able to test this?

No, there is no significant changes since 0.15 to the current version and your options will work just fine. So there may be general recommendations to remove redundancy from your disk backend and then move out journal to separate disk or ssd.

Quoted 6 lines

--
Jens Kristian Søgaard, Mermaid Consulting ApS,
[email protected],
http://www.mermaidconsulting.com/

--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html