Hi,

I have spent a few days thinking about the problem of incremental container assembly when disk sequence numbers (aka event counters) don't match, and how mdadm/mdmon should behave in various situations. Before I start coding on this, I'd like to get your opinion - I may be overlooking something important.

The scenario I look at is that sequence numbers don't match during incremental assembly. This can occur quite easily. A disk may have been missing the last time the array was assembled, and be added again. The last incremental assembly may have been interrupted before all disks were found, for whatever reason. Etc. The problems Francis reported lately all occur in situations of this type.

A) New disk has lower seq number as previously scanned ones:
The up-to-date meta data is the meta data previously parsed.

For each subarray the new disk is a member in the meta data:
A.1) If the subarray is already running, add the new disk a spare. A.2) check the subarray seqnum; if the subarray seqnum is equal
between existing and new disks, the new disk can be added as "clean". (This requires implementing separate seqnums for every subarray, but that can be done quite easily, at least for DDF).
A.3) Otherwise, add the new disk as a spare.

The added disk may be marked as "Missing" or "Faulty" in the meta
data. That will be handled already by existing code already AFAICS.

B) New disk has higher seq number than previously scanned ones. The up-to-date meta data is on the new disk. Here it gets tricky.

B.1) If mdmon isn't running for this container:
B.1.a) reread the meta data (load_container() will automatically
choose the best meta data).
B.1.b) Discard previously made configurations
B.1.c) Reassemble the arrays, starting with the new disk. When
re-adding the drive(s) with the older meta data, act as in A) above.

B.2) If mdmon is already running for this container, it means at
least one subarray is already running, too.
B.2.a) If the new disk belongs to a already running and active
subarray, we have encountered a fatal error. mdadm should refuse to do anything with the new disk and emit an alert.
B.2.b) If the new disk belongs to a already running read-only
subarray, and the subarray seqnum of the new disk is lower than that of the existing disks, we also have a fatal error - we don't know which data is more recent. Human intervention is necessary.
B.2.c) Both mdadm and mdmon need to update the meta data as
described in B.1.a).
B.2.d) If the new disk belongs to a already running read-only
subarray, and the subarray seqnum of the new disk is greater or equal to the subarray seqnum of the existing disk(s), it might be possible to add the new disk to the array as clean. If the seqnum isn't equal, recovery must be started on the previously existing disk(s). Currently the kernel doesn't allow adding a new disk as "clean" in any state except "inactive", so this special case will not be implemented any time soon. It's a general question whether or not mdadm should attempt to be "smart" in situations like this.
B.2.e) Subarrays that aren't running yet, and which the new disk is
a member of, can be reassembled as described in A)
B.2.f) pre-existing disks that are marked missing or failed in the
updated meta data must have their status changed. This may cause the already running array(s) to degrade or break, even if the new disk doen't belong to them.
B.2.g) The status of all subarrays (consistent/initialized) is
updated according to the new meta data.

Note that the really difficult cases B.2.a/b/d can't easily happen if the Incremental assembly is done without "-R", as it should be. So it may be reasonable to just quit with an error if any of these situation is encountered.

An important further question is where this logic should be implemented. This is independent of meta data type and thus most of it should be in the generic Incremental_container() code path.

Feedback welcome.
Best regards
Martin

#1 lore raw

Hello Martin

Quoted 7 lines · Martin Wilck

Hi,

I have spent a few days thinking about the problem of incremental container assembly when disk sequence numbers (aka event counters) don't match, and how mdadm/mdmon should behave in various situations. Before I start coding on this, I'd like to get your opinion - I may be overlooking something important.

I was really suprised to see that this functionnality needs to be implemented since in my understanding, it's the most important one, at least for RAID1.

Isn't this already implemented for IMSM ? If so can't we use the same strategy ?

If not, isn't dmraid supporting it ? If so can't we use the same strategy ?

Thanks

Signature · 1 line
Francis
#2 lore raw
Quoted 11 lines · Francis Moreau

Hello Martin

Quoted 7 lines · Martin Wilck

Hi,

I have spent a few days thinking about the problem of incremental container assembly when disk sequence numbers (aka event counters) don't match, and how mdadm/mdmon should behave in various situations. Before I start coding on this, I'd like to get your opinion - I may be overlooking something important.

Quoted 3 lines

I was really suprised to see that this functionnality needs to be implemented since in my understanding, it's the most important one, at least for RAID1.

Please don't confuse this with the problem you are currently seeing, which looks more like a bug we need to find yet.

I agree this is important, that's why I wrote this RFC, but it's not the most important functionality. AFAICS, the cases that won't work optimally with the current code are pretty rare corner cases. They should be fixed but it isn't too urgent. The "normal" case is that after a failure, you add a new disk (possibly the same one again, as you did in your late testing), and auto-recovery is started.

Quoted 1 line

Isn't this already implemented for IMSM ? If so can't we use the same strategy ?

I don't know the IMSM code well enough to tell. I had a look at it and didn't find code treating this situation, but it's a lot of code, so I may be missing something. I will set up test cases soon.

Quoted 1 line

If not, isn't dmraid supporting it ? If so can't we use the same strategy ?

I think dmraid doesn't have this problem because it doesn't do incremental assembly, as mdadm does. Rather, after udev has settled, dmraid scans its devices; this is similar to running "mdadm -As" at that stage. If you do this, you don't have the problem that possibly an already running array needs to change state because a new disk with more recent meta data is added. Rather, you choose the "best" meta data at assembly time. It would be possible to change the scanning behavior for mdadm by changing the udev rules such that normal assembly is done after udev has settled, rather than incremental on-the-fly assembly.

Martin

#4 lore raw
In reply to Martin Wilck
Quoted 15 lines · On Fri, 20 Sep 2013 22:20:13 +0200 Martin Wilck <[email protected]> wrote:

Hi,

I have spent a few days thinking about the problem of incremental container assembly when disk sequence numbers (aka event counters) don't match, and how mdadm/mdmon should behave in various situations. Before I start coding on this, I'd like to get your opinion - I may be overlooking something important.

The scenario I look at is that sequence numbers don't match during incremental assembly. This can occur quite easily. A disk may have been missing the last time the array was assembled, and be added again. The last incremental assembly may have been interrupted before all disks were found, for whatever reason. Etc. The problems Francis reported lately all occur in situations of this type.

Quoted 5 lines

A) New disk has lower seq number as previously scanned ones:
The up-to-date meta data is the meta data previously parsed.

For each subarray the new disk is a member in the meta data:
A.1) If the subarray is already running, add the new disk a spare.

If the new disk has old metadata, then it might have failed at some point, so we shouldn't add it as anything without good reason.
If the most recent metadata records that a device went missing, rather than actually failed, then it might be justified to add it as a spare. But in general I'd prefer thing were only added as spares if that was explicitly requested of if the policy in mdadm.conf encourages it.

Quoted 48 lines

A.2) check the subarray seqnum; if the subarray seqnum is equal
between existing and new disks, the new disk can be added as "clean". (This requires implementing separate seqnums for every subarray, but that can be done quite easily, at least for DDF).
A.3) Otherwise, add the new disk as a spare.

The added disk may be marked as "Missing" or "Faulty" in the meta
data. That will be handled already by existing code already AFAICS.

B) New disk has higher seq number than previously scanned ones. The up-to-date meta data is on the new disk. Here it gets tricky.

B.1) If mdmon isn't running for this container:
B.1.a) reread the meta data (load_container() will automatically
choose the best meta data).
B.1.b) Discard previously made configurations
B.1.c) Reassemble the arrays, starting with the new disk. When
re-adding the drive(s) with the older meta data, act as in A) above.

B.2) If mdmon is already running for this container, it means at
least one subarray is already running, too.
B.2.a) If the new disk belongs to a already running and active
subarray, we have encountered a fatal error. mdadm should refuse to do anything with the new disk and emit an alert.
B.2.b) If the new disk belongs to a already running read-only
subarray, and the subarray seqnum of the new disk is lower than that of the existing disks, we also have a fatal error - we don't know which data is more recent. Human intervention is necessary.
B.2.c) Both mdadm and mdmon need to update the meta data as
described in B.1.a).
B.2.d) If the new disk belongs to a already running read-only
subarray, and the subarray seqnum of the new disk is greater or equal to the subarray seqnum of the existing disk(s), it might be possible to add the new disk to the array as clean. If the seqnum isn't equal, recovery must be started on the previously existing disk(s). Currently the kernel doesn't allow adding a new disk as "clean" in any state except "inactive", so this special case will not be implemented any time soon. It's a general question whether or not mdadm should attempt to be "smart" in situations like this.
B.2.e) Subarrays that aren't running yet, and which the new disk is
a member of, can be reassembled as described in A)
B.2.f) pre-existing disks that are marked missing or failed in the
updated meta data must have their status changed. This may cause the already running array(s) to degrade or break, even if the new disk doen't belong to them.
B.2.g) The status of all subarrays (consistent/initialized) is
updated according to the new meta data.

Quoted 8 lines

Note that the really difficult cases B.2.a/b/d can't easily happen if the Incremental assembly is done without "-R", as it should be. So it may be reasonable to just quit with an error if any of these situation is encountered.

An important further question is where this logic should be implemented. This is independent of meta data type and thus most of it should be in the generic Incremental_container() code path.

maybe in assemble_container_content? But mdmon need to know about some of it too of course.

Quoted 4 lines

Feedback welcome.
Best regards
Martin

Sounds very sensible, but the devil is in the detail of course. :-)

Thanks,
NeilBrown