Hi,

I put all my replaced and so on HDs in one machine to serve backup duties, with backuppc.

I assembled four raid0, each consiting of a 3 + 1 TB couple or
2 + 2 TB couple. Some of these support scterc, some do not. I've put the following in rc.local (by the way, the system is running Debian):
cd /dev
for x in sd[a-z]; do
/bin/echo $x
"---------------------------------------------------------------------------"

    /usr/sbin/smartctl -s on -o on -S on /dev/$x || echo 
"/usr/sbin/smartctl -s on -o on -S on /dev/$x failed."
    /usr/sbin/smartctl -l scterc,70,70 /dev/$x || echo 180 
Quoted 1 line

/sys/block/$x/device/timeout || echo "/sys/block/$x/device/timeout not available"

    /usr/sbin/smartctl -t offline /dev/$x || echo "/usr/sbin/smartctl 

-t offline /dev/$x failed"
/bin/echo
"-------------------------------------------------------------------------------" done

Afterwards, these four raid0 are the members of a raid5. The idea behind this is to be able to replace the raid0 with single 4 TB drives. Now comes my question: Do I need to care for timeouts of the raid0, and if so, how do I do that? The following doesn't work:
for x in md??; do
/bin/echo $x
"--------------------------------------------------------------------------"

    echo 180 >/sys/block/$x/device/timeout || echo 

"/sys/block/$x/device/timeout not available"
/bin/echo
"-------------------------------------------------------------------------------"
done

Kind regards,
Hans

#1 lore raw

Hi Hans,

Quoted 17 lines · Hans Kraus

Hi,

I put all my replaced and so on HDs in one machine to serve backup duties, with backuppc.

I assembled four raid0, each consiting of a 3 + 1 TB couple or
2 + 2 TB couple. Some of these support scterc, some do not. I've put the following in rc.local (by the way, the system is running Debian):
cd /dev
for x in sd[a-z]; do
/bin/echo $x
"---------------------------------------------------------------------------"

    /usr/sbin/smartctl -s on -o on -S on /dev/$x || echo
"/usr/sbin/smartctl -s on -o on -S on /dev/$x failed."
    /usr/sbin/smartctl -l scterc,70,70 /dev/$x || echo 180
Quoted 6 lines
Quoted 1 line

/sys/block/$x/device/timeout || echo "/sys/block/$x/device/timeout not

available"

    /usr/sbin/smartctl -t offline /dev/$x || echo "/usr/sbin/smartctl -t

offline /dev/$x failed"
/bin/echo
"-------------------------------------------------------------------------------"

Good.

Quoted 11 lines

done

Afterwards, these four raid0 are the members of a raid5. The idea behind this is to be able to replace the raid0 with single 4 TB drives. Now comes my question: Do I need to care for timeouts of the raid0, and if so, how do I do that? The following doesn't work:
for x in md??; do
/bin/echo $x
"--------------------------------------------------------------------------"

Quoted 6 lines
    echo 180 >/sys/block/$x/device/timeout || echo

"/sys/block/$x/device/timeout not available"
/bin/echo
"-------------------------------------------------------------------------------"

done

No. The timeouts only matter on the physical devices. MD doesn't have a timeout as it isn't a physical driver. What you have appears to be correct.

Make sure you also have a "check" scrub in a cron job for everything greater than raid0. (Interval can vary--I use weekly.) And follow up on the cron job with a report of all mismatch-cnt values.

For large capacities with consumer drives (~8TB or more, IMHO), you should seriously consider raid6. The probability of an unrecoverable read error interrupting a raid5 rebuild after a drive failure is shockingly high.

HTH,

Phil

#2 lore raw
Quoted 4 lines · Phil Turmel

Make sure you also have a "check" scrub in a cron job for everything greater than raid0. (Interval can vary--I use weekly.) And follow up on the cron job with a report of all mismatch-cnt values.

RHEL/CentOS already has a script which does this; IIRC it emails root if mismatch_cnt is nonzero after the check is complete.

Quoted 2 lines

For large capacities with consumer drives (~8TB or more, IMHO), you should seriously consider raid6.

I'm assuming you mean arrays larger than 8TB, not individual drives! :) I have had a second drive fail in a large array after the first one failed and a rebuild started, so this isn't just a theoretical discussion.

--keith

Signature · 1 line
[email protected]
author
#3 lore raw
In reply to Phil Turmel

Hi Phil,

thanks. Debian does already a scrub every first Sunday of a month. Upgrading to a Raid6 is planned when I have the money for the disk(s).

I already encountered a second failure during rebuild of a raid5, (that was the trigger for the backup solution), so I'm very aware of that possibility. My main storage is already a raid6, on NAS drives.

Kind regards, Hans

Am 04.11.2013 23:39, schrieb Phil Turmel:

Quoted 32 lines

[...]

Quoted 8 lines

Afterwards, these four raid0 are the members of a raid5. The idea behind this is to be able to replace the raid0 with single 4 TB drives. Now comes my question: Do I need to care for timeouts of the raid0, and if so, how do I do that? The following doesn't work:
for x in md??; do
/bin/echo $x
"--------------------------------------------------------------------------"

Quoted 6 lines
     echo 180 >/sys/block/$x/device/timeout || echo

"/sys/block/$x/device/timeout not available"
/bin/echo
"-------------------------------------------------------------------------------"

done

No. The timeouts only matter on the physical devices. MD doesn't have a timeout as it isn't a physical driver. What you have appears to be correct.

Make sure you also have a "check" scrub in a cron job for everything greater than raid0. (Interval can vary--I use weekly.) And follow up on the cron job with a report of all mismatch-cnt values.

For large capacities with consumer drives (~8TB or more, IMHO), you should seriously consider raid6. The probability of an unrecoverable read error interrupting a raid5 rebuild after a drive failure is shockingly high.

HTH,

Phil