Skip to contentSkip to conversation

osm_drop_mgr.c: fix timeouts on Get Pkey from ext switch ports

PATCH New Hal Rosenstock 1 participant 1 message Nov 6, 2013 InfiniBand

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 osm_drop_mgr.c: fix timeouts on Get Pkey from ext switch ports

From: Alex Netes <alexne-VPRAkNaXOzVWk0Htik3J/[email protected]>

In case SM doesn't recieve PkeyTable GetResp from external switch ports, it should clear the PkeyTable GetResp counter and set physp->need_update = 2, in order to resend PkeyTable Get on the next sweep.

---
 opensm/osm_drop_mgr.c |    2 ++
 1 files changed, 2 insertions(+), 0 deletions(-)
opensm/osm_drop_mgr.c +2 -0
index 7e7c7f6..cb685cb 100644
@@ -582,6 +582,8 @@ void osm_drop_mgr_process(osm_sm_t * sm)
 				p_physp = osm_node_get_physp_ptr(p_node, port_num);
 				if (!p_physp || p_physp->pkeys.rcv_blocks_cnt == 0)
 					continue;
+				p_physp->pkeys.rcv_blocks_cnt = 0;
+				p_physp->need_update = 2;
 				sm->p_subn->subnet_initialization_error = TRUE;
 				port_guid = osm_physp_get_port_guid(p_physp);
 				p_port = osm_get_port_by_guid(sm->p_subn, port_guid);
Signature · 6 lines
1.7.8.2

--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in
the body of a message to [email protected]