This is a resend from earlier today as it never seems to have reached the list. Sorry to anyone who gets it twice...

Hi All

We have had a couple of new interface discussions buried in the reviews of drivers. Specifically the quaternion rotation interface and the pulse capture interface. In some ways as will become apparent below these are related.

I'm summarising the options here in an attempt to get some more discussion going.

Firstly, the quaternion interface. Quaternions require 4 components to be presented together in order for any meaning to be extracted. Thus it makes no sense to ever present their components separately. To this end a new interface is proposed in which all 4 components are presented as a space separated list. Whilst I welcome comments on this, the actual question I am raising here concerns not what is presented, but the way we indicate that this is what is to be expected.

Two obvious options exist as we have two places this type could be 'represented'. Either we introduce a new channel type - rotquaternion which is defined to be a rotation expressed as a quaternion, or we take the existing channel type rot and apply a modifier (similar to an axis modifier) to indicate that rather than being a rotation about a given axis, we have a rotation represented as a quaternion. This would be done with a new modifier. To illustrate the point, lets take a few example sysfs attributes.

Option 1. New channel type

in_rotquaternion1_raw
in_rotquaternion1_scale

Option 2. New modifier.

in_rot1_quaternion_raw
in_rot1_quaternion_scale

Next lets take the ecap driver and it's pulse characteristic measurement interface. Here we have a single underlying thing (the waveform) about which we wish to measure a number of elements. Again, we can either do this via new channel types, or via modifiers. Note there is precedence for using index numbers to indicate that multiple measurements are being taken via the same physical wire of different things.

Option 1. New Channel types (I'm making the naming up as a go along - the aim here is generality to other things we might measure and time intervals are more general than 'pulse' or similar types)

in_interval1_high_raw (time pulse is high)
in_interval_scale

in_interval1_low_raw (time pulse is low)

in_interval_risingtorising_raw (period measured rising edge to rising edge) in_interval_fallingtofalling_raw (period measured falling to falling)

in_interval_rising_raw (rise time of waveform).
in_interval_falling_raw (fall time of waveform).

in_voltage_peaktopeak_raw (peak to peak voltage). We actually have interfaces in place for this sort of stuff.

Option 2 - modifiers for everything. (this is what I suggested in -
http://www.spinics.net/lists/linux-omap/msg103204.html

in_waveformX_hightime_raw
in_waveformX_lowtime_raw
in_waveformX_period_raw
in_waveformX_markspace_raw
in_waveformX_peaktopeak_raw
in_waveformX_risetime_raw
in_waveformX_falltime_raw

Personally my thinking has changed since my ecap related email. I think we want to keep the channel types to be strictly what quantity is being measured and rely on shared index numbers to indicate that we are dealing with multiple measurements of a given 'channel'.

Hence I slightly favour option 1. However the reason I'm sending this RFC is I definitely want more input on this decision from other regular IIO developers (and anyone else!). I'm particularly interested in cases that people don't think are cleanly covered by the proposed options. I've picked a few people to poke via ccing them, but please do send this on to anyone else you think might contribute to the discussion.

It's going to tie us to a large body of ABI moving forwards. My apologies to Matt and Srinivas for the fact your drivers have gotten caught up in this, but we need to get it right.

Whilst we are talking interface reviews. Another one I proposed recently was spherical coordinates for position measurements. The main reason for this is that it gives a unified way of indicating distance from sensor as

in_position_r_raw

There are also magnetic position sensors that report in full spherical coordinates so we may want the other elements down the line. I'm kind of regretting letting the generic 'proximity' interface in now. Those are measuring something related to distance, but material dependent so I'm not too bothered if we introduced another similar interface. Anyone comments on this would be great as well as I'd like to get the lightning sensor merged sooner rather than later!

I hate my webmail, but then its better than doing it on my mobile phone..

Thanks

Jonathan

#1 lore raw

Hi Jonathan,

thanks for the very good presentation.

Quoted 19 lines

Firstly, the quaternion interface. Quaternions require 4 components to be presented together in order for any meaning to be extracted. Thus it makes no sense to ever present their components separately. To this end a new interface is proposed in which all 4 components are presented as a space separated list. Whilst I welcome comments on this, the actual question I am raising here concerns not what is presented, but the way we indicate that this is what is to be expected.

Two obvious options exist as we have two places this type could be 'represented'. Either we introduce a new channel type - rotquaternion which is defined to be a rotation expressed as a quaternion, or we take the existing channel type rot and apply a modifier (similar to an axis modifier) to indicate that rather than being a rotation about a given axis, we have a rotation represented as a quaternion. This would be done with a new modifier. To illustrate the point, lets take a few example sysfs attributes.

Option 1. New channel type

Quoted 7 lines

in_rotquaternion1_raw
in_rotquaternion1_scale

Option 2. New modifier.

in_rot1_quaternion_raw
in_rot1_quaternion_scale

I prefer option 2 since we still measure a rotation, but an axis makes no sense. I'd even propose to additionally have:

in_rot1_xyz_raw

to present x y and z in one single reading since a lot of sensor supply a measurement from the same point in time when reading out all values together.

Quoted 42 lines

Next lets take the ecap driver and it's pulse characteristic measurement interface. Here we have a single underlying thing (the waveform) about which we wish to measure a number of elements. Again, we can either do this via new channel types, or via modifiers. Note there is precedence for using index numbers to indicate that multiple measurements are being taken via the same physical wire of different things.

Option 1. New Channel types (I'm making the naming up as a go along - the aim here is generality to other things we might measure and time intervals are more general than 'pulse' or similar types)

in_interval1_high_raw (time pulse is high)
in_interval_scale

in_interval1_low_raw (time pulse is low)

in_interval_risingtorising_raw (period measured rising edge to rising edge) in_interval_fallingtofalling_raw (period measured falling to falling)

in_interval_rising_raw (rise time of waveform).
in_interval_falling_raw (fall time of waveform).

in_voltage_peaktopeak_raw (peak to peak voltage). We actually have interfaces in place for this sort of stuff.

Option 2 - modifiers for everything. (this is what I suggested in -
http://www.spinics.net/lists/linux-omap/msg103204.html

in_waveformX_hightime_raw
in_waveformX_lowtime_raw
in_waveformX_period_raw
in_waveformX_markspace_raw
in_waveformX_peaktopeak_raw
in_waveformX_risetime_raw
in_waveformX_falltime_raw

Personally my thinking has changed since my ecap related email. I think we want to keep the channel types to be strictly what quantity is being measured and rely on shared index numbers to indicate that we are dealing with multiple measurements of a given 'channel'.

Quoted 6 lines

Hence I slightly favour option 1. However the reason I'm sending this RFC is I definitely want more input on this decision from other regular IIO developers (and anyone else!). I'm particularly interested in cases that people don't think are cleanly covered by the proposed options. I've picked a few people to poke via ccing them, but please do send this on to anyone else you think might contribute to the discussion.

Here I'm with you. Your arguments make perfectly sense for me.

Quoted 10 lines

It's going to tie us to a large body of ABI moving forwards. My apologies to Matt and Srinivas for the fact your drivers have gotten caught up in this, but we need to get it right.

Whilst we are talking interface reviews. Another one I proposed recently was spherical coordinates for position measurements. The main reason for this is that it gives a unified way of indicating distance from sensor as

in_position_r_raw

Why would this be a position when you actually measure distance? Can you give an example?

Quoted 7 lines

There are also magnetic position sensors that report in full spherical coordinates so we may want the other elements down the line. I'm kind of regretting letting the generic 'proximity' interface in now. Those are measuring something related to distance, but material dependent so I'm not too bothered if we introduced another similar interface. Anyone comments on this would be great as well as I'd like to get the lightning sensor merged sooner rather than later!

Regards,
Manuel

author maintainer
#2 lore raw
Quoted 38 lines · Manuel Stahl

Hi Jonathan,

thanks for the very good presentation.

Quoted 1 line

Firstly, the quaternion interface. Quaternions require 4 components

to

Quoted 1 line

be presented together in order for any meaning to be extracted. Thus

it

Quoted 1 line

makes no sense to ever present their components separately. To this

end

Quoted 1 line

a new interface is proposed in which all 4 components are presented

as

Quoted 1 line

a space separated list. Whilst I welcome comments on this, the

actual

Quoted 1 line

question I am raising here concerns not what is presented, but the

way we

Quoted 4 lines

indicate that this is what is to be expected.

Two obvious options exist as we have two places this type could be 'represented'. Either we introduce a new channel type -

rotquaternion

Quoted 1 line

which is defined to be a rotation expressed as a quaternion, or we

take

Quoted 1 line

the existing channel type rot and apply a modifier (similar to an

axis

Quoted 2 lines

modifier) to indicate that rather than being a rotation about a given axis, we have a rotation represented as a quaternion. This would be

done

Quoted 1 line

with a new modifier. To illustrate the point, lets take a few

example

Quoted 7 lines

sysfs attributes.

Option 1. New channel type

in_rotquaternion1_raw
in_rotquaternion1_scale

Quoted 7 lines
Quoted 4 lines

Option 2. New modifier.

in_rot1_quaternion_raw
in_rot1_quaternion_scale

I prefer option 2 since we still measure a rotation, but an axis makes no sense.

I suppose this also fits better against proposal of allowing spherical position coords below. There we have on distance and two angles. In conjunction they specify the position.

Quoted 7 lines

I'd even propose to additionally have:

in_rot1_xyz_raw

to present x y and z in one single reading since a lot of sensor supply a measurement from the same point in time when reading out all values together.

Maybe... But there will be lots of combinations possible. Xz xy yz xyz

These would be sysfs only probably with the individual elements taking precedence for
buffered output.

Quoted 77 lines
Quoted 4 lines

Next lets take the ecap driver and it's pulse characteristic

measurement

Quoted 1 line

interface. Here we have a single underlying thing (the waveform)

about

Quoted 1 line

which we wish to measure a number of elements. Again, we can either

do

Quoted 1 line

this via new channel types, or via modifiers. Note there is

precedence for

Quoted 1 line

using index numbers to indicate that multiple measurements are being

taken

Quoted 3 lines

via the same physical wire of different things.

Option 1. New Channel types (I'm making the naming up as a go along -

the

Quoted 1 line

aim here is generality to other things we might measure and time

intervals

Quoted 8 lines

are more general than 'pulse' or similar types)

in_interval1_high_raw (time pulse is high)
in_interval_scale

in_interval1_low_raw (time pulse is low)

in_interval_risingtorising_raw (period measured rising edge to rising

edge)

Quoted 20 lines

in_interval_fallingtofalling_raw (period measured falling to falling)

in_interval_rising_raw (rise time of waveform).
in_interval_falling_raw (fall time of waveform).

in_voltage_peaktopeak_raw (peak to peak voltage). We actually have interfaces in place for this sort of stuff.

Option 2 - modifiers for everything. (this is what I suggested in -
http://www.spinics.net/lists/linux-omap/msg103204.html

in_waveformX_hightime_raw
in_waveformX_lowtime_raw
in_waveformX_period_raw
in_waveformX_markspace_raw
in_waveformX_peaktopeak_raw
in_waveformX_risetime_raw
in_waveformX_falltime_raw

Quoted 2 lines

Personally my thinking has changed since my ecap related email. I think we want to keep the channel types to be strictly what

quantity

Quoted 4 lines

is being measured and rely on shared index numbers to indicate that we are dealing with multiple measurements of a given 'channel'.

Hence I slightly favour option 1. However the reason I'm sending

this

Quoted 1 line

RFC is I definitely want more input on this decision from other

regular

Quoted 2 lines

IIO developers (and anyone else!). I'm particularly interested in cases that people don't think are cleanly covered by the proposed

options.

Quoted 1 line

I've picked a few people to poke via ccing them, but please do send

this

Quoted 1 line

on to anyone else you think might contribute to the discussion.

Here I'm with you. Your arguments make perfectly sense for me.

Quoted 2 lines

It's going to tie us to a large body of ABI moving forwards. My apologies to Matt and Srinivas for the fact your drivers have

gotten

Quoted 3 lines

caught up in this, but we need to get it right.

Whilst we are talking interface reviews. Another one I proposed

recently

Quoted 2 lines

was spherical coordinates for position measurements. The main reason for this is that it gives a unified way of indicating distance from

Quoted 7 lines

sensor

Quoted 3 lines

as

in_position_r_raw

Why would this be a position when you actually measure distance? Can you give an example?

In spherical coordinates the r is merely the distance from the reference point. To do full position you would have two angle coordinates as well.

Thanks

J

Quoted 19 lines
Quoted 2 lines

There are also magnetic position sensors that report in full

spherical

Quoted 2 lines

coordinates so we may want the other elements down the line. I'm kind of regretting letting the generic 'proximity' interface in

now.

Quoted 1 line

Those are measuring something related to distance, but material

dependent

Quoted 3 lines

so I'm not too bothered if we introduced another similar interface. Anyone comments on this would be great as well as I'd like to get the lightning sensor merged sooner rather than later!

Regards,
Manuel

--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Signature · 1 line
Sent from my Android phone with K-9 Mail. Please excuse my brevity.