Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°C
Right Fan and temp4 are for sure incorrect.
Value temp4 is always 127 and is never changing, but value for Right Fan is increasing when fan is more noisy. So it looks like value for Right Fan is not correctly normalized or multiplier is incorrect.
And name "Right" is incorrect too. Fan is on left side of this notebook, not right as reported by driver.
It is possible to fix these problems?
Signature · 2 lines
Pali Rohár [email protected]
Hi Pali,
Quoted 3 lines · Pali Rohár
Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
That's kind of excessive wording, the output isn't that bad.
Quoted 10 lines
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°CRight Fan and temp4 are for sure incorrect.
Driver is reverse-engineered so this is best effort and some tweaking may be needed.
Quoted 9 lines
Value temp4 is always 127 and is never changing, but value for Right Fan is increasing when fan is more noisy. So it looks like value for Right Fan is not correctly normalized or multiplier is incorrect.
And name "Right" is incorrect too. Fan is on left side of this notebook, not right as reported by driver.
It is possible to fix these problems?
Load the i8k driver with fan_mult=1.
Add the following to /etc/sensors.d/i8k.conf:
chip "i8k-virtual-0"
label fan2 "Left Fan"
ignore temp4
Signature · 2 lines
Jean Delvare SUSE L3 Support
Quoted 10 lines · On Friday 16 May 2014 21:11:17 Jean Delvare wrote:
Hi Pali,
Quoted 4 lines · Pali Rohár
Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
That's kind of excessive wording, the output isn't that bad.
I mean fan RPM & temp4. Those are for sure incorrect.
Quoted 9 lines
Quoted 9 lines
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°C
Quoted 5 lines
Quoted 1 line
Right Fan and temp4 are for sure incorrect.
Driver is reverse-engineered so this is best effort and some tweaking may be needed.
Ok, if driver is developed without any documentation, then it make sense that not working correctly on new machines...
So is not there any documentation? I think that Dell released some SMM/BIOS code... But I'm not sure about it.
Quoted 5 lines
Quoted 5 lines
Value temp4 is always 127 and is never changing, but value for Right Fan is increasing when fan is more noisy. So it looks like value for Right Fan is not correctly normalized or multiplier is incorrect.
Quoted 7 lines
Quoted 4 lines
And name "Right" is incorrect too. Fan is on left side of this notebook, not right as reported by driver.
It is possible to fix these problems?
Load the i8k driver with fan_mult=1.
Looks like now it reports more plausible value for fan. When fan is at low it reporting between 3000 - 3100 RPM.
Quoted 6 lines
Add the following to
/etc/sensors.d/i8k.conf:chip "i8k-virtual-0"
label fan2 "Left Fan"
ignore temp4
And this fixing output from sensors program.
$ sensors i8k-virtual-0 Adapter: Virtual device Left Fan: 3088 RPM CPU: +54.0°C temp2: +57.0°C temp3: +40.0°C
But Right Fan name is still present in kernel sysfs:
$ grep "" /sys/class/hwmon/hwmon1/* /sys/class/hwmon/hwmon1/fan2_input:3091 /sys/class/hwmon/hwmon1/fan2_label:Right Fan /sys/class/hwmon/hwmon1/name:i8k /sys/class/hwmon/hwmon1/pwm2:128 /sys/class/hwmon/hwmon1/temp1_input:56000 /sys/class/hwmon/hwmon1/temp1_label:CPU /sys/class/hwmon/hwmon1/temp2_input:57000 /sys/class/hwmon/hwmon1/temp3_input:40000 /sys/class/hwmon/hwmon1/temp4_input:127000
Signature · 2 lines
Pali Rohár [email protected]
Quoted 2 lines · Pali Rohár
So is not there any documentation? I think that Dell released some SMM/BIOS code... But I'm not sure about it.
I don't know either. But even with some SMM/BIOS code, it doesn't tell you which sensors are present on which machines, nor what they correspond to, nor what scaling factors need to be applied.
Quoted 25 lines
Quoted 2 lines
(...)
Load the i8k driver with fan_mult=1.Looks like now it reports more plausible value for fan. When fan is at low it reporting between 3000 - 3100 RPM.
Quoted 6 lines
Add the following to
/etc/sensors.d/i8k.conf:chip "i8k-virtual-0"
label fan2 "Left Fan"
ignore temp4And this fixing output from sensors program.
$ sensors i8k-virtual-0 Adapter: Virtual device Left Fan: 3088 RPM CPU: +54.0°C temp2: +57.0°C temp3: +40.0°CBut Right Fan name is still present in kernel sysfs:
Quoted 10 lines
$ grep "" /sys/class/hwmon/hwmon1/* /sys/class/hwmon/hwmon1/fan2_input:3091 /sys/class/hwmon/hwmon1/fan2_label:Right Fan /sys/class/hwmon/hwmon1/name:i8k /sys/class/hwmon/hwmon1/pwm2:128 /sys/class/hwmon/hwmon1/temp1_input:56000 /sys/class/hwmon/hwmon1/temp1_label:CPU /sys/class/hwmon/hwmon1/temp2_input:57000 /sys/class/hwmon/hwmon1/temp3_input:40000 /sys/class/hwmon/hwmon1/temp4_input:127000
The drivers sets default labels in sysfs, the libsensors configuration files lets you override these defaults with your own labels.
Signature · 2 lines
Jean Delvare SUSE L3 Support
Quoted 29 lines · Pali Rohár
Quoted 10 lines · On Friday 16 May 2014 21:11:17 Jean Delvare wrote:
Hi Pali,
Quoted 4 lines · Pali Rohár
Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
That's kind of excessive wording, the output isn't that bad.
I mean fan RPM & temp4. Those are for sure incorrect.
Quoted 9 lines
Quoted 9 lines
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°CQuoted 5 lines
Quoted 1 line
Right Fan and temp4 are for sure incorrect.
Driver is reverse-engineered so this is best effort and some tweaking may be needed.
Quoted 6 lines
Ok, if driver is developed without any documentation, then it make sense that not working correctly on new machines...
So is not there any documentation? I think that Dell released some SMM/BIOS code... But I'm not sure about it.
If you find it, please let us know.
Guenter
Quoted 32 lines · On Saturday 17 May 2014 17:34:34 Guenter Roeck wrote:
Quoted 31 lines · Pali Rohár
Quoted 10 lines · On Friday 16 May 2014 21:11:17 Jean Delvare wrote:
Hi Pali,
Quoted 4 lines · Pali Rohár
Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
That's kind of excessive wording, the output isn't that bad.
I mean fan RPM & temp4. Those are for sure incorrect.
Quoted 9 lines
Quoted 9 lines
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°CQuoted 4 lines
Quoted 1 line
Right Fan and temp4 are for sure incorrect.
Driver is reverse-engineered so this is best effort and some tweaking may be needed.
Ok, if driver is developed without any documentation, then it make sense that not working correctly on new machines...
Quoted 6 lines
Quoted 2 lines
So is not there any documentation? I think that Dell released some SMM/BIOS code... But I'm not sure about it.
If you find it, please let us know.
Guenter
Now I remembered... Dell has released info about their smbios extensions with example programs at:
https://linux.dell.com/libsmbios/main/
https://linux.dell.com/cgi-bin/gitweb/gitweb.cgi?p=libsmbios.git;a=summary
But there is nothing about fan control or temperature.
Also I found smbios specification:
http://www.dmtf.org/standards/smbios
There is something written about fan and temp, but no idea if it is usefull for something...
Signature · 2 lines
Pali Rohár [email protected]
Quoted 9 lines · Pali Rohár
Now I remembered... Dell has released info about their smbios extensions with example programs at:
https://linux.dell.com/libsmbios/main/
https://linux.dell.com/cgi-bin/gitweb/gitweb.cgi?p=libsmbios.git;a=summaryBut there is nothing about fan control or temperature.
Quoted 6 lines
Also I found smbios specification:
http://www.dmtf.org/standards/smbios
There is something written about fan and temp, but no idea if it is usefull for something...
No, it's not useful to solve your problem.
Signature · 2 lines
Jean Delvare SUSE L3 Support
Quoted 28 lines · Jean Delvare
Hi Pali,
Quoted 3 lines · Pali Rohár
Hello,
on Dell Latitude E6440 driver i8k reporting total nonsense values
That's kind of excessive wording, the output isn't that bad.
Quoted 10 lines
$ sensors i8k-virtual-0 Adapter: Virtual device Right Fan: 93450 RPM CPU: +57.0°C temp2: +57.0°C temp3: +40.0°C temp4: +127.0°CRight Fan and temp4 are for sure incorrect.
Driver is reverse-engineered so this is best effort and some tweaking may be needed.
Quoted 5 lines
Value temp4 is always 127 and is never changing, but value for Right Fan is increasing when fan is more noisy. So it looks like value for Right Fan is not correctly normalized or multiplier is incorrect.
Quoted 7 lines
Quoted 4 lines
And name "Right" is incorrect too. Fan is on left side of this notebook, not right as reported by driver.
It is possible to fix these problems?
Load the i8k driver with fan_mult=1.
Would it make sense to change the default multiplier to 1 ? Lots of people have problems with it, and trying to figure out affected machines one by one would be an all but impossible task.
Guenter
Quoted 6 lines · Guenter Roeck
Quoted 1 line · Jean Delvare
Load the i8k driver with fan_mult=1.
Would it make sense to change the default multiplier to 1 ? Lots of people have problems with it, and trying to figure out affected machines one by one would be an all but impossible task.
That would cause a regression on many (presumably older) machines. I doubt this is acceptable. One option would be to use the ACPI year to change the default, if indeed all new machines need fan_mult=1. I don't know if this is the case.
One this I had in mind was auto-detecting the scaling factor. AFAIK only 30 and 1 are possible values, so any value above ~300 would imply scaling factor of 1 (30 would make it > 9000 RPM which is unrealistic.) But I don't know if we can actually do that, as such a simple heuristic could easily fail is the fan is stopped (30 * 0 == 1 * 0) or if the returned raw speed is temporarily unreliable for whatever reason.
I have to admit that working on a reverse engineered driver for hardware I don't even have isn't quite at the top of my to-do list.
Signature · 2 lines
Jean Delvare SUSE L3 Support
Quoted 13 lines · Jean Delvare
Quoted 6 lines · Guenter Roeck
Quoted 1 line · Jean Delvare
Load the i8k driver with fan_mult=1.
Would it make sense to change the default multiplier to 1 ? Lots of people have problems with it, and trying to figure out affected machines one by one would be an all but impossible task.
That would cause a regression on many (presumably older) machines. I doubt this is acceptable. One option would be to use the ACPI year to change the default, if indeed all new machines need fan_mult=1. I don't know if this is the case.
Quoted 7 lines
One this I had in mind was auto-detecting the scaling factor. AFAIK only 30 and 1 are possible values, so any value above ~300 would imply scaling factor of 1 (30 would make it > 9000 RPM which is unrealistic.) But I don't know if we can actually do that, as such a simple heuristic could easily fail is the fan is stopped (30 * 0 == 1 * 0) or if the returned raw speed is temporarily unreliable for whatever reason.
Sounds like an idea. We could make the cutoff higher, such as 500 or even 1000. I am not much concerned about 0 rpm - the code could simply check the returned rpm and adjust the scaling factor to 1 if the reading is too high. Since 30*0 is still 0, there is no problem if the fan is stopped.
Quoted 3 lines
I have to admit that working on a reverse engineered driver for hardware I don't even have isn't quite at the top of my to-do list.
;-). We have several of those systems, so there is at least some interest on my side. If I have time, I'll play around with it. The driver does need major cleanup, though, so that may take a while.
Guenter