timer drift
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6, and only since recent changes).
What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is more precise, because it is the sum of short durations computed with xnarch_llmulshft, whereas on the clock side, we pass larger and larger values to xnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a few micro-seconds after hours of tests). I have verified that replacing xnarch_llmulshft with xnarch_nodiv_llimd avoids the issue. And I believe mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.
Regards.
Signature · 1 line
Gilles.
Quoted 7 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6, and only since recent changes).
Quoted 11 lines
What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is more precise, because it is the sum of short durations computed with
xnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.
The question being: what do we do to avoid this issue?
Signature · 1 line
Gilles.
Quoted 20 lines · Gilles Chanteperdrix
Quoted 7 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6, and only since recent changes).
Quoted 11 lines
What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is more precise, because it is the sum of short durations computed with
xnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.
Quoted 3 lines
The question being: what do we do to avoid this issue?
IIUC, assuming clock_gettime() delivers ns2tsc(N * period_ns), we may have to fix the timer interval update code in xnclock_tick() which produces N * (ns2tsc(period_ns)). Aligning both could be the right path, maybe compensating for the overhead using the clock gravity?
Signature · 1 line
Philippe.
Quoted 21 lines · Philippe Gerum
Quoted 20 lines · Gilles Chanteperdrix
Quoted 18 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6, and only since recent changes).
What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is more precise, because it is the sum of short durations computed with
xnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.
Quoted 9 lines
Quoted 3 lines
The question being: what do we do to avoid this issue?
IIUC, assuming
clock_gettime()deliversns2tsc(N * period_ns), we may have to fix the timer interval update code inxnclock_tick()which produces N * (ns2tsc(period_ns)). Aligning both could be the right path, maybe compensating for the overhead using the clock gravity?
s/clock gravity/timer gravity/ which would then depend on the timer being periodic or not. We'd need to calibrate this adjustement cost on low end architectures, only to make sure this is worth the burden.
Signature · 1 line
Philippe.
Quoted 32 lines · Philippe Gerum
Quoted 21 lines · Philippe Gerum
Quoted 20 lines · Gilles Chanteperdrix
Quoted 18 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6, and only since recent changes).
What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is more precise, because it is the sum of short durations computed with
xnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.Quoted 9 lines
Quoted 3 lines
The question being: what do we do to avoid this issue?
IIUC, assuming
clock_gettime()deliversns2tsc(N * period_ns), we may have to fix the timer interval update code inxnclock_tick()which produces N * (ns2tsc(period_ns)). Aligning both could be the right path, maybe compensating for the overhead using the clock gravity?
Quoted 4 lines
s/clock gravity/timer gravity/ which would then depend on the timer being periodic or not. We'd need to calibrate this adjustement cost on low end architectures, only to make sure this is worth the burden.
The overhead is a multiplication followed by the computation of ns2tsc, which is an llmulshft, so only takes a few nanoseconds. We have the "arith" test which measures llmulshft. The worst case I have is on at91rm9200 a few hundreds of nanoseconds, with latency in the 200us range.
I think it is best to leave the gravity configuration to the user, as we have always done. Maybe having a "per timer-class" gravity would make sense (for user vs kernel thread vs kernel timer and periodic vs one-shot), but it seems it would make the tuning complicated.
Signature · 1 line
Gilles.
Quoted 47 lines · Gilles Chanteperdrix
Quoted 37 lines · Philippe Gerum
Quoted 26 lines · Philippe Gerum
Quoted 25 lines · Gilles Chanteperdrix
Quoted 23 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6,
and only since recent changes).What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is
more precise, because it is the sum of short durations computed withxnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a
few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe
mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.Quoted 9 lines
Quoted 3 lines
The question being: what do we do to avoid this issue?
IIUC, assuming
clock_gettime()deliversns2tsc(N * period_ns), we may have to fix the timer interval update code inxnclock_tick()which produces N * (ns2tsc(period_ns)). Aligning both could be the right path, maybe compensating for the overhead using the clock gravity?Quoted 4 lines
s/clock gravity/timer gravity/ which would then depend on the timer being periodic or not. We'd need to calibrate this adjustement cost on low end architectures, only to make sure this is worth the burden.
The overhead is a multiplication followed by the computation of ns2tsc, which is an llmulshft, so only takes a few nanoseconds. We have the "arith" test which measures llmulshft. The worst case I have is on at91rm9200 a few hundreds of nanoseconds, with latency in the 200us range.
Quoted 5 lines
I think it is best to leave the gravity configuration to the user, as we have always done. Maybe having a "per timer-class" gravity would make sense (for user vs kernel thread vs kernel timer and periodic vs one-shot), but it seems it would make the tuning complicated.
With Cobalt, timers now have a thread affinity.
Signature · 1 line
Philippe.
Quoted 48 lines · Philippe Gerum
Quoted 47 lines · Gilles Chanteperdrix
Quoted 37 lines · Philippe Gerum
Quoted 26 lines · Philippe Gerum
Quoted 25 lines · Gilles Chanteperdrix
Quoted 23 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6,
and only since recent changes).What the latency test does is create a periodic timer, and when waking up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is
more precise, because it is the sum of short durations computed withxnarch_llmulshft, whereas on the clock side, we pass larger and larger values toxnarch_llmulshft, so at some point, the error due to the approximation begins to be within the range of observable differences (a
few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe
mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.Quoted 9 lines
Quoted 3 lines
The question being: what do we do to avoid this issue?
IIUC, assuming
clock_gettime()deliversns2tsc(N * period_ns), we may have to fix the timer interval update code inxnclock_tick()which produces N * (ns2tsc(period_ns)). Aligning both could be the right path, maybe compensating for the overhead using the clock gravity?Quoted 4 lines
s/clock gravity/timer gravity/ which would then depend on the timer being periodic or not. We'd need to calibrate this adjustement cost on low end architectures, only to make sure this is worth the burden.
The overhead is a multiplication followed by the computation of ns2tsc, which is an llmulshft, so only takes a few nanoseconds. We have the "arith" test which measures llmulshft. The worst case I have is on at91rm9200 a few hundreds of nanoseconds, with latency in the 200us range.
Quoted 8 lines
Quoted 5 lines
I think it is best to leave the gravity configuration to the user, as we have always done. Maybe having a "per timer-class" gravity would make sense (for user vs kernel thread vs kernel timer and periodic vs one-shot), but it seems it would make the tuning complicated.
With Cobalt, timers now have a thread affinity.
You mean gravity?
Signature · 1 line
Gilles.
Quoted 59 lines · Gilles Chanteperdrix
Quoted 58 lines · Philippe Gerum
Quoted 56 lines · Gilles Chanteperdrix
Quoted 40 lines · Philippe Gerum
Quoted 32 lines · Philippe Gerum
Quoted 27 lines · Gilles Chanteperdrix
Quoted 17 lines · Gilles Chanteperdrix
Hi,
when running the latency test modified to use timerfds on forge, I noticed that we have a clock vs timer drift issue (on forge, not on 2.6,
and only since recent changes).What the latency test does is create a periodic timer, and when waking
up at each tick, compare the actual wake-up time, with the expected wake-up time. The problem is that, on the timer side, the computation is
more precise, because it is the sum of short durations computed withxnarch_llmulshft, whereas on the clock side, we pass larger and larger
values toxnarch_llmulshft, so at some point, the error due to theQuoted 8 lines
approximation begins to be within the range of observable differences (a
few micro-seconds after hours of tests). I have verified that replacingxnarch_llmulshftwithxnarch_nodiv_llimdavoids the issue. And I believe
mainline does not have the same issue because they always pass small durations to the multiplication + shift operation.Quoted 3 lines
The question being: what do we do to avoid this issue?
Quoted 6 lines
IIUC, assuming
clock_gettime()deliversns2tsc(N * period_ns), we may have to fix the timer interval update code inxnclock_tick()which produces N * (ns2tsc(period_ns)). Aligning both could be the right path,
maybe compensating for the overhead using the clock gravity?Quoted 4 lines
s/clock gravity/timer gravity/ which would then depend on the timer being periodic or not. We'd need to calibrate this adjustement cost on low end architectures, only to make sure this is worth the burden.
The overhead is a multiplication followed by the computation of ns2tsc, which is an llmulshft, so only takes a few nanoseconds. We have the "arith" test which measures llmulshft. The worst case I have is on at91rm9200 a few hundreds of nanoseconds, with latency in the 200us range.
I think it is best to leave the gravity configuration to the user, as we have always done. Maybe having a "per timer-class" gravity would make sense (for user vs kernel thread vs kernel timer and periodic vs one-shot), but it seems it would make the tuning complicated.
Quoted 4 lines
Quoted 2 lines
With Cobalt, timers now have a thread affinity.
You mean gravity?
I mean we do have an optional thread affinity assigned to each timer, which is currently used to figure out the best CPU affinity for such timer. We could use this information for determining the most appropriate timer gravity, directly from __xntimer_init(), for any timer for which a thread affinity has been given.
Signature · 1 line
Philippe.