PATCH 3/7 ARM: shmobile: Disable DVS support for r8a7790

Since range of VDD is narrow, there is no effect of power consumption by DVS. So, DVS is disabled in R-CAR Gen2 series.

---
 arch/arm/boot/dts/r8a7790-lager.dts |    4 ----
 1 file changed, 4 deletions(-)
arch/arm/boot/dts/r8a7790-lager.dts +0 -4
index ab73ed0..9becef7 100644
@@ -317,7 +317,3 @@
 	cd-gpios = <&gpio3 22 GPIO_ACTIVE_LOW>;
 	status = "okay";
 };
-
-&cpu0 {
-	cpu0-supply = <&vdd_dvfs>;
-};
Signature · 1 line
1.7.9.5
#1 lore raw

Hello.

Quoted 13 lines · Gaku Inami

Since range of VDD is narrow, there is no effect of power consumption by DVS. So, DVS is disabled in R-CAR Gen2 series.

---
  arch/arm/boot/dts/r8a7790-lager.dts |    4 ----
  1 file changed, 4 deletions(-)
arch/arm/boot/dts/r8a7790-lager.dts +0 -0
index ab73ed0..9becef7 100644

arch/arm/boot/dts/r8a7790-lager.dts line 323

Quoted 7 lines
arch/arm/boot/dts/r8a7790-lager.dts +0 -4
@@ -317,7 +317,3 @@
  	cd-gpios = <&gpio3 22 GPIO_ACTIVE_LOW>;
  	status = "okay";
  };
-
-&cpu0 {
-	cpu0-supply = <&vdd_dvfs>;
-};

Why enable it in the first place (patch #1)?

WBR, Sergei

author
#2 lore raw
In reply to Gaku Inami

Hi Sergei

Quoted 5 lines
Quoted 5 lines
arch/arm/boot/dts/r8a7790-lager.dts +0 -0
index ab73ed0..9becef7 100644
@@ -317,7 +317,3 @@
Quoted 9 lines

arch/arm/boot/dts/r8a7790-lager.dts line 323

Quoted 7 lines
arch/arm/boot/dts/r8a7790-lager.dts +0 -4
  	cd-gpios = <&gpio3 22 GPIO_ACTIVE_LOW>;
  	status = "okay";
  };
-
-&cpu0 {
-	cpu0-supply = <&vdd_dvfs>;
-};

Why enable it in the first place (patch #1)?

patch #1 is created by Benoit. At the first, I thought better to create a separate patch without changing his code. After that, I understand that this method was wrong.

I will re-post by changing the patch #1. (disable DVS)

#3 lore raw
In reply to Gaku Inami

(CC Benoit)

Quoted 13 lines · Gaku Inami

Since range of VDD is narrow, there is no effect of power consumption by DVS. So, DVS is disabled in R-CAR Gen2 series.

---
 arch/arm/boot/dts/r8a7790-lager.dts |    4 ----
 1 file changed, 4 deletions(-)
arch/arm/boot/dts/r8a7790-lager.dts +0 -0
index ab73ed0..9becef7 100644

arch/arm/boot/dts/r8a7790-lager.dts line 323

Quoted 7 lines
arch/arm/boot/dts/r8a7790-lager.dts +0 -4
@@ -317,7 +317,3 @@
        cd-gpios = <&gpio3 22 GPIO_ACTIVE_LOW>;
        status = "okay";
 };
-
-&cpu0 {
-       cpu0-supply = <&vdd_dvfs>;
-};

The role of the DT is to describe the hardware.
Not using DVS because the effect of power consumption is low or non-existent is a software policy.

So perhaps it should be kept?

Gr{oetje,eeting}s,

Geert

--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- [email protected]

In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that.
-- Linus Torvalds

author
#4 lore raw
In reply to Gaku Inami

Hi Geert

Thank you for your feedback.

Quoted 5 lines

The role of the DT is to describe the hardware.
Not using DVS because the effect of power consumption is low or non-existent is a software policy.

So perhaps it should be kept?

I understand what you mean. I will keep the setting of VDD into DT, and consider to disable DVS in a different way.

#5 lore raw
In reply to Gaku Inami

Hi,

Quoted 4 lines · Gaku Inami

Hi Geert

Thank you for your feedback.

Quoted 9 lines
Quoted 5 lines

The role of the DT is to describe the hardware.
Not using DVS because the effect of power consumption is low or non-existent is a software policy.

So perhaps it should be kept?

I understand what you mean. I will keep the setting of VDD into DT, and consider to disable DVS in a different way.

Indeed, the line "cpu0-supply = <&vdd_dvfs>;" does just provide the name of the power rail that supply the ca15 cluster.

The postfix _dvfs is a little bit misleading in this case, I do agree.

If you do no want voltage scaling, it is just a matter of keeping the same voltage in the OPP table. This is what I have done in the series I sent a while back.

That being said, what is the exact voltage range supported by the CPU? AFAIR, with 28nm process some SoCs are able to scale down to 0.9v.

Thanks,
Benoit

Signature · 4 lines
Benoît Cousson
BayLibre
Embedded Linux Technology Lab
www.baylibre.com
author
#6 lore raw
In reply to Gaku Inami

Hi Benoit

Thank you for your feedback.

Quoted 6 lines

Indeed, the line "cpu0-supply = <&vdd_dvfs>;" does just provide the name of the power rail that supply the ca15 cluster.

The postfix _dvfs is a little bit misleading in this case, I do agree.

If you do no want voltage scaling, it is just a matter of keeping the same voltage in the OPP table. This is what I have done in the series I sent a while back.

When I tested, the voltage scaling is not disabled with only voltage setting of OPP table. The regulator side(da9210) must also be set to the same voltage.
(When voltage scaling is activated, the environment will be unstable.)

I will post the fixed patch later.

Quoted 3 lines

That being said, what is the exact voltage range supported by the CPU? AFAIR, with 28nm process some SoCs are able to scale down to 0.9v.

I do not have this information.