Hi,

I am having a problem in using analogy calls to read from a NatIns PCI-MIO-16E-4

I installed Xenomai 2.6.3 on a freshly installed Kubuntu 10.4 followed all the instructions and the kernel running is 3.8.13-xenomai-2.6.3. The latency test did run without problems.

I tried the example programs in /opt/xenomai-2.6.3/src/utils/analogy/ in particular insn_read it seems to work except for the fact that it doesn't seem to set the range, but just rescale (wrongly) the result The raw output (for a square wave 100mv amp) is between 0x0810 and 0x07e8 and If run "insn_read -R X" it gives values that change i.e
X max min
0 0.080 -0.115
1 0.040 -0.057
2 0.020 -0.024
3 0.006 -0.012

And so on: it rescale for a range but it doesn't set it properly

I tried to write a small prog that just does one read using a4l_sync_read and I have seen from an old message that you should use
PACK() to set the range but If I pass PACK(0,1,0) to the function
to pass the range I get this error:
4l_sync_read failed (err=-22)

How can I fix this?

Thanks,

GianPiero