novena: Fix ethernet PHY reset sequence
PATCH 1/1 novena: Fix ethernet PHY reset sequence
From: Nikolay Dimitrov <[email protected]>
This patch fixes conflict between PHY pins becoming outputs after reset and imx6 still driving the pins. It also fixes the reset timing as recommended by the PHY datasheet.
--- board/kosagi/novena/novena.c | 3 -- board/kosagi/novena/novena_spl.c | 64 +++++++++++++++++++++++++++----------- 2 files changed, 46 insertions(+), 21 deletions(-)
board/kosagi/novena/novena.c +0 -3
@@ -237,9 +237,6 @@ int board_early_init_f(void)setup_display ();#endif -/* Bring Ethernet PHY out of reset. */ -gpio_set_value (IMX_GPIO_NR (3 ,23 ),1 ); -return 0 ; }
board/kosagi/novena/novena_spl.c +46 -18
85 lines not on this page · raw message
Signature · 1 line
1.7.10.4
PATCH 1/1 novena: Fix ethernet PHY reset sequence
Quoted 10 lines · On Sun, Oct 12, 2014 at 7:47 AM, <[email protected]> wrote:
From: Nikolay Dimitrov <[email protected]>
This patch fixes conflict between PHY pins becoming outputs after reset and imx6 still driving the pins. It also fixes the reset timing as recommended by the PHY datasheet.
Signed-off-by Nikolay Dimitrov <[email protected]>Cc Stefano Babic <[email protected]>Cc Sean Cross <[email protected]>Cc Marek Vasut <[email protected]>
PATCH 1/1 novena: Fix ethernet PHY reset sequence
In reply to picmaster at mail.bgQuoted 11 lines · picmaster at mail.bg
From: Nikolay Dimitrov <[email protected]>
This patch fixes conflict between PHY pins becoming outputs after reset and imx6 still driving the pins. It also fixes the reset timing as recommended by the PHY datasheet.
Signed-off-by Nikolay Dimitrov <[email protected]>Cc Stefano Babic <[email protected]>Cc Sean Cross <[email protected]>Cc Marek Vasut <[email protected]>---
Applied to u-boot-imx, thanks !
Best regards,
Stefano Babic
Signature · 5 lines
===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================