iio:adc:ad799x driver broken after commit "Write default config on probe and reset alert status on probe"
Subsystems (2)
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 5 lines · Mike Looijmans
After this commit:
iio:adc:ad799x: Write default config on probe and reset alert status on
probe
Quoted 7 lines
writing
ALERT_ENandBUSY_ALERTto the chip config register clears pending alerts,BUSY_ALERTis cleared when reading back the registerThe AD7999 on our board no longer functions, reading the in_voltage*_raw sysfiles always returns "255" after this.
I reverted the commit, and that fixed the problem for me.
I suspect that there is something going wrong when reading back the config register, can you check the attached patch and see what the output is?
Thanks,
- Lars
drivers/iio/adc/ad799x.c +2 -0
@@ -816,6 +816,8 @@ static int ad799x_probe(struct i2c_client *client,if (ret <0 ) goto error_disable_reg; st->config = ret; +dev_info (&client->dev,"config: %x %x\n" , st->config, + st->chip_config->default_config); ret =iio_triggered_buffer_setup (indio_dev,NULL , &ad799x_trigger_handler,NULL );
Quoted 12 lines · Lars-Peter Clausen
Quoted 11 lines · Mike Looijmans
After this commit:
iio:adc:ad799x: Write default config on probe and reset alert status on
probewriting
ALERT_ENandBUSY_ALERTto the chip config register clears pending alerts,BUSY_ALERTis cleared when reading back the registerThe AD7999 on our board no longer functions, reading the in_voltage*_raw sysfiles always returns "255" after this.
Quoted 8 lines
Quoted 1 line
I reverted the commit, and that fixed the problem for me.
I suspect that there is something going wrong when reading back the config register, can you check the attached patch and see what the output is?
Thanks,
- Lars
The attached patch delivered the following output (using the current head code):
ad799x 1-0029: config: b 0
Met vriendelijke groet / kind regards,
Mike Looijmans
System Expert
TOPIC Embedded Systems Eindhovenseweg 32-C, NL-5683 KH Best Postbus 440, NL-5680 AK Best
Telefoon: (+31) (0) 499 33 69 79
Telefax: (+31) (0) 499 33 69 70
E-mail: [email protected]
Website: www.topic.nl
Please consider the environment before printing this e-mail
Topic zoekt gedreven (embedded) software specialisten!
http://topic.nl/vacatures/topic-zoekt-software-engineers/
Quoted 18 lines · Mike Looijmans
Quoted 17 lines · Lars-Peter Clausen
Quoted 5 lines · Mike Looijmans
After this commit:
iio:adc:ad799x: Write default config on probe and reset alert status on
probeQuoted 7 lines
writing
ALERT_ENandBUSY_ALERTto the chip config register clears pending alerts,BUSY_ALERTis cleared when reading back the registerThe AD7999 on our board no longer functions, reading the in_voltage*_raw sysfiles always returns "255" after this.
I reverted the commit, and that fixed the problem for me.
I suspect that there is something going wrong when reading back the config register, can you check the attached patch and see what the output is?
Quoted 9 lines
Quoted 3 lines
Thanks,
- LarsThe attached patch delivered the following output (using the current head code):
ad799x 1-0029: config: b 0
Yea, kind of what I expected based on your description. Looking at the datasheet it seems the ad7999 doesn't even support register read back which would explain the issue. I'll try to find a board and see if I can fix it.