STAGING: Fix pcl818.c coding style issue: code indent should use tabs where possible
PATCH 1/3 STAGING: Fix pcl818.c coding style issue: code indent should use tabs where possible
Correct one coding style problem(detected by checkpatch.pl) in pcl818.c.
- code indent should use tabs where possible
--- drivers/staging/comedi/drivers/pcl818.c | 26 +++++++++++++------------- 1 file changed, 13 insertions(+), 13 deletions(-)
drivers/staging/comedi/drivers/pcl818.c +13 -13
@@ -45,11 +45,11 @@ A word or two about DMA. Driver support DMA operations at two ways: [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=A/D input -5V.. +5V - 1, 10=A/D input -10V..+10V + 1, 10=A/D input -10V..+10V [5] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) + 1, 10=D/A output 0-10V (internal reference -10V) 2 =D/A output unknown (external reference) Options for PCL-818, PCL-818H:
@@ -57,28 +57,28 @@ A word or two about DMA. Driver support DMA operations at two ways: [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) + 1, 10=D/A output 0-10V (internal reference -10V) 2 =D/A output unknown (external reference) Options for PCL-818HD, PCL-818HG: [0] - IO Base [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA/FIFO (-1=use FIFO, 0=disable both FIFO and DMA, - 1=use DMA ch 1, 3=use DMA ch 3) + 1=use DMA ch 1, 3=use DMA ch 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) - 2 =D/A output unknown (external reference) + 1, 10=D/A output 0-10V (internal reference -10V) + 2 =D/A output unknown (external reference) Options for PCL-718: [0] - IO Base [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0=A/D Range is +/-10V 1= +/-5V 2= +/-2.5V
@@ -87,14 +87,14 @@ A word or two about DMA. Driver support DMA operations at two ways:5= user defined bipolar 6= 0-10V 7= 0-5V -8= 0-2V +8= 0-2V 9= 0-1V 10= user defined unipolar [5] - 0, 5=D/A outputs 0-5V (internal reference -5V) -1, 10=D/A outputs 0-10V (internal reference -10V) +1, 10=D/A outputs 0-10V (internal reference -10V) 2=D/A outputs unknown (external reference) [6] - 0, 60=max 60kHz A/D sampling -1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) +1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) */
Signature · 1 line
1.8.1.2
Quoted 70 lines · Simon Guo
Correct one coding style problem(detected by checkpatch.pl) in
pcl818.c.
- code indent should use tabs where possibleSigned-off-by Simon Guo <[email protected]>--- drivers/staging/comedi/drivers/pcl818.c | 26 +++++++++++++------------- 1 file changed, 13 insertions(+), 13 deletions(-)drivers/staging/comedi/drivers/pcl818.c +11
-11@@ -45,11 +45,11 @@ A word or two about DMA. Driver support DMA operations at two ways: [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=A/D input -5V.. +5V - 1, 10=A/D input -10V..+10V + 1, 10=A/D input -10V..+10V [5] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) + 1, 10=D/A output 0-10V (internal reference -10V) 2 =D/A output unknown (external reference) Options for PCL-818, PCL-818H:@@ -57,28 +57,28 @@ A word or two about DMA. Driver support DMA operations at two ways: [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) + 1, 10=D/A output 0-10V (internal reference -10V) 2 =D/A output unknown (external reference) Options for PCL-818HD, PCL-818HG: [0] - IO Base [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA/FIFO (-1=use FIFO, 0=disable both FIFO and DMA, - 1=use DMA ch 1, 3=use DMA ch 3) + 1=use DMA ch 1, 3=use DMA ch 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) - 2 =D/A output unknown (external reference) + 1, 10=D/A output 0-10V (internal reference -10V) + 2 =D/A output unknown (external reference) Options for PCL-718: [0] - IO Base [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) [2] - DMA (0=disable, 1, 3) [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 + 1= 1MHz clock for 8254 [4] - 0=A/D Range is +/-10V 1= +/-5V 2= +/-2.5V@@ -87,14 +87,14 @@ A word or two about DMA. Driver support DMA operations at two ways: 5= user defined bipolar 6= 0-10V 7= 0-5V - 8= 0-2V + 8= 0-2V 9= 0-1V
drivers/staging/comedi/drivers/pcl818.c A word or two about DMA. Driver support DMA operations at two ways: · line 99
Quoted 10 lines
drivers/staging/comedi/drivers/pcl818.c +2
-210= user defined unipolar [5] - 0, 5=D/A outputs 0-5V (internal reference -5V) -1, 10=D/A outputs 0-10V (internal reference -10V) +1, 10=D/A outputs 0-10V (internal reference -10V) 2=D/A outputs unknown (external reference) [6] - 0, 60=max 60kHz A/D sampling -1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) +1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) */
Okay, but this comment block really needs reformatting to use the usual block comment style, and with spaces to line up the columns instead of tabs so it still looks okay when the " * " is removed from the start of each line of the block comment.
Signature · 2 lines
-=( Ian Abbott @ MEV Ltd. E-mail: <[email protected]> )=- -=( Web: http://www.mev.co.uk/ )=-
Ian,
Quoted 8 lines · Ian Abbott
Okay, but this comment block really needs reformatting to use the usual block comment style, and with spaces to line up the columns instead of tabs so it still looks okay when the " * " is removed from the start of each line of the block comment.
Reviewed-by Ian Abbott <[email protected]>
Thanks for your comments for my patch 1~3. I will rework and resend the 3 patches.
BR,
Simon