Skip to contentSkip to conversation

please help - raid 1 degraded

DISCUSSION [email protected] 4 participants 8 messages Feb 11, 2015 – Feb 12, 2015 MD RAID

lore
Share & tools
lore
#0 lore raw

centos 6.6
2x 240gig ssd in raid1
this is a live running production machine and the raid1 is for /u of users home dirs.

1 ssd went totally offline and i replaced it after noticing the firmware levels are not the same. the new ssd has the same level firmware.

/dev/sdb is the good ssd
/dev/sdc is the new blank ssd

when working it was /u1 from /dev/md127p1 and /u2 from /dev/md127p2 p1 is 80gig and p2 is 160gig for the full 240gig size of the ssd

Quoted 1 line

ls -al /dev/md*

brw-rw---- 1 root disk 9, 127 Feb 11 11:09 /dev/md127
brw-rw---- 1 root disk 259, 0 Feb 10 20:23 /dev/md127p1
brw-rw---- 1 root disk 259, 1 Feb 10 20:23 /dev/md127p2

/dev/md:
total 8
drwxr-xr-x 2 root root 140 Feb 10 20:24 .
drwxr-xr-x 20 root root 3980 Feb 10 20:24 ..

lrwxrwxrwx  1 root root    8 Feb 11 11:09 240ssd_0 -> ../md127
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p1 -> ../md127p1
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p2 -> ../md127p2
-rw-r--r--  1 root root    5 Feb 10 20:24 autorebuild.pid
-rw-------  1 root root   63 Feb 10 20:23 md-device-map
Quoted 1 line

ps -eaf | grep mdadm

root 2188 1 0 Feb10 ? 00:00:00 mdadm --monitor --scan -f --pid-file=/var/run/mdadm/mdadm.pid

how do i rebuild /dev/sdc into the mirror of /dev/sdb?

and thanks much for the help!
steve

#1 lore raw
Quoted 29 lines · On 12/02/15 05:04, [email protected] wrote:

centos 6.6
2x 240gig ssd in raid1
this is a live running production machine and the raid1 is for /u of users home dirs.

1 ssd went totally offline and i replaced it after noticing the firmware levels are not the same. the new ssd has the same level firmware.

/dev/sdb is the good ssd
/dev/sdc is the new blank ssd

when working it was /u1 from /dev/md127p1 and /u2 from /dev/md127p2 p1 is 80gig and p2 is 160gig for the full 240gig size of the ssd

Quoted 1 line

ls -al /dev/md*

brw-rw---- 1 root disk 9, 127 Feb 11 11:09 /dev/md127
brw-rw---- 1 root disk 259, 0 Feb 10 20:23 /dev/md127p1
brw-rw---- 1 root disk 259, 1 Feb 10 20:23 /dev/md127p2

/dev/md:
total 8
drwxr-xr-x 2 root root 140 Feb 10 20:24 .
drwxr-xr-x 20 root root 3980 Feb 10 20:24 ..

lrwxrwxrwx  1 root root    8 Feb 11 11:09 240ssd_0 -> ../md127
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p1 -> ../md127p1
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p2 -> ../md127p2
(quoted diff) +0 -2
-rw-r--r--  1 root root    5 Feb 10 20:24 autorebuild.pid
-rw-------  1 root root   63 Feb 10 20:23 md-device-map
Quoted 5 lines
Quoted 1 line

ps -eaf | grep mdadm

root 2188 1 0 Feb10 ? 00:00:00 mdadm --monitor --scan -f --pid-file=/var/run/mdadm/mdadm.pid

how do i rebuild /dev/sdc into the mirror of /dev/sdb?

Please send the output of fdisk -lu /dev/sd[bc] and cat /proc/mdstat (preferably both when it was working and current).

In general, when replacing a failed RAID1 disk, and assuming you configured it the way I think you did:
1) fdisk -lu /dev/sdb
Find out the exact partition sizes
2) fdisk /dev/sdc
Create the new partitions exactly the same as /dev/sdb
3) mdadm --manage /dev/md127 --add /dev/sdb1
Add the partition to the array
4) cat /proc/mdstat
Watch the rebuild progress, once it is complete, relax.

PS, steps 1 and 2 may not be needed if you are using the full block device instead of a partition. Also, change the command in step 3 to "mdadm --manage /dev/md127 --add /dev/sdb"

PPS, if this is a bootable disk, you will probably also need to do something with your boot manager to get that installed onto the new disk as well.

Hope this helps, otherwise, please provide more information.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au
#2 lore raw
Quoted 58 lines · Adam Goryachev
Quoted 29 lines · On 12/02/15 05:04, [email protected] wrote:

centos 6.6
2x 240gig ssd in raid1
this is a live running production machine and the raid1 is for /u of users home dirs.

1 ssd went totally offline and i replaced it after noticing the firmware levels are not the same. the new ssd has the same level firmware.

/dev/sdb is the good ssd
/dev/sdc is the new blank ssd

when working it was /u1 from /dev/md127p1 and /u2 from /dev/md127p2 p1 is 80gig and p2 is 160gig for the full 240gig size of the ssd

Quoted 1 line

ls -al /dev/md*

brw-rw---- 1 root disk 9, 127 Feb 11 11:09 /dev/md127
brw-rw---- 1 root disk 259, 0 Feb 10 20:23 /dev/md127p1
brw-rw---- 1 root disk 259, 1 Feb 10 20:23 /dev/md127p2

/dev/md:
total 8
drwxr-xr-x 2 root root 140 Feb 10 20:24 .
drwxr-xr-x 20 root root 3980 Feb 10 20:24 ..

lrwxrwxrwx  1 root root    8 Feb 11 11:09 240ssd_0 -> ../md127
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p1 -> ../md127p1
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p2 -> ../md127p2
(quoted diff) +0 -2
-rw-r--r--  1 root root    5 Feb 10 20:24 autorebuild.pid
-rw-------  1 root root   63 Feb 10 20:23 md-device-map
Quoted 5 lines
Quoted 1 line

ps -eaf | grep mdadm

root 2188 1 0 Feb10 ? 00:00:00 mdadm --monitor --scan -f --pid-file=/var/run/mdadm/mdadm.pid

how do i rebuild /dev/sdc into the mirror of /dev/sdb?

Please send the output of fdisk -lu /dev/sd[bc] and cat /proc/mdstat (preferably both when it was working and current).

In general, when replacing a failed RAID1 disk, and assuming you configured it the way I think you did:
1) fdisk -lu /dev/sdb
Find out the exact partition sizes
2) fdisk /dev/sdc
Create the new partitions exactly the same as /dev/sdb
3) mdadm --manage /dev/md127 --add /dev/sdb1
Add the partition to the array
4) cat /proc/mdstat
Watch the rebuild progress, once it is complete, relax.

PS, steps 1 and 2 may not be needed if you are using the full block device instead of a partition. Also, change the command in step 3 to "mdadm --manage /dev/md127 --add /dev/sdb"

PPS, if this is a bootable disk, you will probably also need to do something with your boot manager to get that installed onto the new disk as well.

Quoted 8 lines

Hope this helps, otherwise, please provide more information.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au

Adam (and anybody else that can help),
after issue i do not have before. and no they are not bootable.

[root@shell ~]# fdisk -lu /dev/sd[bc]

Disk /dev/sdb: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0001a740

Disk /dev/sdc: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x00000000

[root@shell ~]# cat /proc/mdstat
Personalities : [raid1]
md127 : active raid1 sdb[2]

      234299840 blocks super 1.2 [2/1] [U_]

unused devices: <none>

[root@shell ~]# fdisk -lu /dev/sdb

Disk /dev/sdb: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0001a740

i dont seem to be seeing the partition sizes or im stupid. couldnt i just dd if=/dev/sdb of=/dev/sdc bs=1G count=240 and then do the mdadm?

#3 lore raw
Quoted 89 lines · On 12/02/15 11:09, [email protected] wrote:
Quoted 57 lines · Adam Goryachev
Quoted 29 lines · On 12/02/15 05:04, [email protected] wrote:

centos 6.6
2x 240gig ssd in raid1
this is a live running production machine and the raid1 is for /u of users home dirs.

1 ssd went totally offline and i replaced it after noticing the firmware levels are not the same. the new ssd has the same level firmware.

/dev/sdb is the good ssd
/dev/sdc is the new blank ssd

when working it was /u1 from /dev/md127p1 and /u2 from /dev/md127p2 p1 is 80gig and p2 is 160gig for the full 240gig size of the ssd

Quoted 1 line

ls -al /dev/md*

brw-rw---- 1 root disk 9, 127 Feb 11 11:09 /dev/md127
brw-rw---- 1 root disk 259, 0 Feb 10 20:23 /dev/md127p1
brw-rw---- 1 root disk 259, 1 Feb 10 20:23 /dev/md127p2

/dev/md:
total 8
drwxr-xr-x 2 root root 140 Feb 10 20:24 .
drwxr-xr-x 20 root root 3980 Feb 10 20:24 ..

lrwxrwxrwx  1 root root    8 Feb 11 11:09 240ssd_0 -> ../md127
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p1 -> ../md127p1
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p2 -> ../md127p2
(quoted diff) +0 -2
-rw-r--r--  1 root root    5 Feb 10 20:24 autorebuild.pid
-rw-------  1 root root   63 Feb 10 20:23 md-device-map
Quoted 5 lines
Quoted 1 line

ps -eaf | grep mdadm

root 2188 1 0 Feb10 ? 00:00:00 mdadm --monitor --scan -f --pid-file=/var/run/mdadm/mdadm.pid

how do i rebuild /dev/sdc into the mirror of /dev/sdb?

Please send the output of fdisk -lu /dev/sd[bc] and cat /proc/mdstat (preferably both when it was working and current).

In general, when replacing a failed RAID1 disk, and assuming you configured it the way I think you did:
1) fdisk -lu /dev/sdb
Find out the exact partition sizes
2) fdisk /dev/sdc
Create the new partitions exactly the same as /dev/sdb
3) mdadm --manage /dev/md127 --add /dev/sdb1
Add the partition to the array
4) cat /proc/mdstat
Watch the rebuild progress, once it is complete, relax.

PS, steps 1 and 2 may not be needed if you are using the full block device instead of a partition. Also, change the command in step 3 to "mdadm --manage /dev/md127 --add /dev/sdb"

PPS, if this is a bootable disk, you will probably also need to do something with your boot manager to get that installed onto the new disk as well.

Quoted 8 lines

Hope this helps, otherwise, please provide more information.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au

Adam (and anybody else that can help),
after issue i do not have before. and no they are not bootable.

[root@shell ~]# fdisk -lu /dev/sd[bc]

Disk /dev/sdb: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0001a740

Disk /dev/sdc: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x00000000

[root@shell ~]# cat /proc/mdstat
Personalities : [raid1]
md127 : active raid1 sdb[2]

Quoted 7 lines
       234299840 blocks super 1.2 [2/1] [U_]

unused devices: <none>

i dont seem to be seeing the partition sizes or im stupid. couldnt i just dd if=/dev/sdb of=/dev/sdc bs=1G count=240 and then do the mdadm?

OK, so you aren't using partitioned disks, so it is as simple as what I said above (with one minor correction):

"mdadm --manage /dev/md127 --add /dev/sdc"

/dev/sdc is the new blank ssd, so that is the one to add, the above command with /dev/sdb wouldn't have done anything at all .... So just run that command, and then do "watch cat /proc/mdstat" until the good stuff is completed.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au
#4 lore raw
Quoted 103 lines · Adam Goryachev
Quoted 89 lines · On 12/02/15 11:09, [email protected] wrote:
Quoted 57 lines · Adam Goryachev
Quoted 29 lines · On 12/02/15 05:04, [email protected] wrote:

centos 6.6
2x 240gig ssd in raid1
this is a live running production machine and the raid1 is for /u of users home dirs.

1 ssd went totally offline and i replaced it after noticing the firmware levels are not the same. the new ssd has the same level firmware.

/dev/sdb is the good ssd
/dev/sdc is the new blank ssd

when working it was /u1 from /dev/md127p1 and /u2 from /dev/md127p2 p1 is 80gig and p2 is 160gig for the full 240gig size of the ssd

Quoted 1 line

ls -al /dev/md*

brw-rw---- 1 root disk 9, 127 Feb 11 11:09 /dev/md127
brw-rw---- 1 root disk 259, 0 Feb 10 20:23 /dev/md127p1
brw-rw---- 1 root disk 259, 1 Feb 10 20:23 /dev/md127p2

/dev/md:
total 8
drwxr-xr-x 2 root root 140 Feb 10 20:24 .
drwxr-xr-x 20 root root 3980 Feb 10 20:24 ..

lrwxrwxrwx  1 root root    8 Feb 11 11:09 240ssd_0 -> ../md127
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p1 -> ../md127p1
lrwxrwxrwx  1 root root   10 Feb 10 20:23 240ssd_0p2 -> ../md127p2
(quoted diff) +0 -2
-rw-r--r--  1 root root    5 Feb 10 20:24 autorebuild.pid
-rw-------  1 root root   63 Feb 10 20:23 md-device-map
Quoted 5 lines
Quoted 1 line

ps -eaf | grep mdadm

root 2188 1 0 Feb10 ? 00:00:00 mdadm --monitor --scan -f --pid-file=/var/run/mdadm/mdadm.pid

how do i rebuild /dev/sdc into the mirror of /dev/sdb?

Please send the output of fdisk -lu /dev/sd[bc] and cat /proc/mdstat (preferably both when it was working and current).

In general, when replacing a failed RAID1 disk, and assuming you configured it the way I think you did:
1) fdisk -lu /dev/sdb
Find out the exact partition sizes
2) fdisk /dev/sdc
Create the new partitions exactly the same as /dev/sdb
3) mdadm --manage /dev/md127 --add /dev/sdb1
Add the partition to the array
4) cat /proc/mdstat
Watch the rebuild progress, once it is complete, relax.

PS, steps 1 and 2 may not be needed if you are using the full block device instead of a partition. Also, change the command in step 3 to "mdadm --manage /dev/md127 --add /dev/sdb"

PPS, if this is a bootable disk, you will probably also need to do something with your boot manager to get that installed onto the new disk as well.

Quoted 8 lines

Hope this helps, otherwise, please provide more information.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au

Adam (and anybody else that can help),
after issue i do not have before. and no they are not bootable.

[root@shell ~]# fdisk -lu /dev/sd[bc]

Disk /dev/sdb: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0001a740

Disk /dev/sdc: 240.1 GB, 240057409536 bytes
255 heads, 63 sectors/track, 29185 cylinders, total 468862128 sectors Units = sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x00000000

[root@shell ~]# cat /proc/mdstat
Personalities : [raid1]
md127 : active raid1 sdb[2]

Quoted 7 lines
       234299840 blocks super 1.2 [2/1] [U_]

unused devices: <none>

i dont seem to be seeing the partition sizes or im stupid. couldnt i just dd if=/dev/sdb of=/dev/sdc bs=1G count=240 and then do the mdadm?

OK, so you aren't using partitioned disks, so it is as simple as what I said above (with one minor correction):

"mdadm --manage /dev/md127 --add /dev/sdc"

Quoted 10 lines

/dev/sdc is the new blank ssd, so that is the one to add, the above command with /dev/sdb wouldn't have done anything at all .... So just run that command, and then do "watch cat /proc/mdstat" until the good stuff is completed.

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au

awesome sauce!
it is recovering and at a fast pace too. says it will be done in 16mins.

ok, so now the really important questions:
once done, what files/stats do i need to save off for the next time it craters?

#5 lore raw
Quoted 1 line · On 12/02/15 12:02, [email protected] wrote:

ok, so now the really important questions: once done, what files/stats do i need to save off for the next time it craters?

I think the usual information requested is the following:
fdisk -lu /dev/sd?
mdadm --manage --query /dev/sd?
mdadm --manage --detail /dev/md*
mdadm --manage --examine /dev/sd?
cat /proc/mdstat
ls -l /dev/disk/by-id/

If you can keep a copy of all those things, then you will be much further ahead than many people. Of course, RAID1 is just so much easier/simpler than RAID5/RAID6, so usually you won't need any of that. RAID1 is simple mirror, so if you have two disks, one with data, one without, then you just need to decide which disk has the data, and start with that. It is even possible to start two MD arrays, one from each disk, and then compare the contents to decide which one you want to keep.
Or, you can simply mount the device directly (skipping any MD data at the beginning if needed).

Like I said, RAID1 is by far the simplest type of RAID if you want redundancy and can fit your dataset onto a single device.

Glad you had a successful recovery :)

Regards,
Adam

Signature · 1 line
Adam Goryachev Website Managers www.websitemanagers.com.au
#6 lore raw
Quoted 8 lines · Adam Goryachev
Quoted 1 line · On 12/02/15 12:02, [email protected] wrote:

ok, so now the really important questions: once done, what files/stats do i need to save off for the next time it craters?

I think the usual information requested is the following:
fdisk -lu /dev/sd?
mdadm --manage --query /dev/sd?
mdadm --manage --detail /dev/md*
mdadm --manage --examine /dev/sd?

Maybe

	mdadm --misc --query   /dev/md*
        mdadm --misc --detail  /dev/md*
        mdadm --misc --examine /dev/sd*
Quoted 14 lines

cat /proc/mdstat
ls -l /dev/disk/by-id/

If you can keep a copy of all those things, then you will be much further ahead than many people. Of course, RAID1 is just so much easier/simpler than RAID5/RAID6, so usually you won't need any of that. RAID1 is simple mirror, so if you have two disks, one with data, one without, then you just need to decide which disk has the data, and start with that. It is even possible to start two MD arrays, one from each disk, and then compare the contents to decide which one you want to keep.
Or, you can simply mount the device directly (skipping any MD data at the beginning if needed).

Like I said, RAID1 is by far the simplest type of RAID if you want redundancy and can fit your dataset onto a single device.

Glad you had a successful recovery :)

Regards,
Adam

Signature · 1 line
Eyal Lebedinsky ([email protected])
#7 lore raw
In reply to [email protected]
Quoted 3 lines · On 12/02/2015 00:09, [email protected] wrote:

i dont seem to be seeing the partition sizes or im stupid. couldnt i just dd if=/dev/sdb of=/dev/sdc bs=1G count=240 and then do the mdadm?

NOT a good idea. I don't know what it would do in your case, where you are using the entire disk, but if you're using a partition table you would suddenly end up with a bunch of duplicate GUIDs. Bearing in mind the "GU" stands for "globally unique", your management tools are likely to get confused ... not a good idea especially wrt raid.

Cheers,
Wol