extcon: arizona: Simplify pdata symantics for micd_dbtime
PATCH v6 1/1 extcon: arizona: Simplify pdata symantics for micd_dbtime
Currently micd_dbtime can be set to 0 for default, 1 for 4 measurements, or a greater than 16-bit value for 2 measurements. This patch simplifies the symantics to 2 for 2 measurements, 4 for 4 measurements and any other value for the default.
I am not super keen on changing the symantics of the pdata at this stage in the drivers life, but acceptance of the DT binding for this field has been made conditional on this happening.
---
Changes from v5:
- Move defines into extcon driver, rather than pdata header, it is unlikely that they would have seen any use there anyway and they can be moved there in a later change if needed.
Thanks,
Charles
drivers/extcon/extcon-arizona.c | 17 ++++++++++++++--- 1 files changed, 14 insertions(+), 3 deletions(-)
drivers/extcon/extcon-arizona.c +14 -3
@@ -48,6 +48,9 @@#define HPDET_DEBOUNCE 500#define DEFAULT_MICD_TIMEOUT 2000 +#define MICD_DBTIME_TWO_READINGS 2 +#define MICD_DBTIME_FOUR_READINGS 4 +#define MICD_LVL_1_TO_7 (ARIZONA_MICD_LVL_1 | ARIZONA_MICD_LVL_2 | \ ARIZONA_MICD_LVL_3 | ARIZONA_MICD_LVL_4 | \ ARIZONA_MICD_LVL_5 | ARIZONA_MICD_LVL_6 | \
@@ -1318,11 +1321,19 @@ static int arizona_extcon_probe(struct platform_device *pdev) arizona->pdata.micd_rate << ARIZONA_MICD_RATE_SHIFT); -if (arizona->pdata.micd_dbtime) +switch (arizona->pdata.micd_dbtime) { +case MICD_DBTIME_FOUR_READINGS :regmap_update_bits (arizona->regmap,ARIZONA_MIC_DETECT_1 ,ARIZONA_MICD_DBTIME_MASK , - arizona->pdata.micd_dbtime - <<ARIZONA_MICD_DBTIME_SHIFT ); +ARIZONA_MICD_DBTIME ); +break ; +case MICD_DBTIME_TWO_READINGS : +regmap_update_bits (arizona->regmap,ARIZONA_MIC_DETECT_1 , +ARIZONA_MICD_DBTIME_MASK ,0 ); +break ; +default : +break ; + }BUILD_BUG_ON (ARRAY_SIZE (arizona_micd_levels) !=0x40 );
Signature · 1 line
1.7.2.5
Chanwoo Choi
maintainerQuoted 5 lines · Charles Keepax
Currently
micd_dbtimecan be set to 0 for default, 1 for 4 measurements, or a greater than 16-bit value for 2 measurements. This patch simplifies the symantics to 2 for 2 measurements, 4 for 4 measurements and any other value for the default.
Quoted 7 lines
I am not super keen on changing the symantics of the pdata at this stage in the drivers life, but acceptance of the DT binding for this field has been made conditional on this happening.
Signed-off-by Charles Keepax <[email protected]>---
Applied it.
Thanks,