Requesting inclusion of 26bb0e9a in linux-3.14.y
Subsystems (2)
Hello,
This is my first time requesting inclusion of a patch, please point out any breach of protocol.
I'm using linux-3.14.y and I've run into a bug fixed in later kernel versions:
commit 26bb0e9a1a938ec98ee07aa76533f1a711fba706
Author: Lukasz Majewski <[email protected]> Date: Wed Sep 24 10:27:10 2014 +0200
thermal: step_wise: fix: Prevent from binary overflow when trend is dropping
It turns out that some boards can have instance->lower greater than 0 and when thermal trend is dropping it results with next_target equal to -1.
Since the next_target is defined as unsigned long it is interpreted as 0xFFFFFFFF and larger than instance->upper.
As a result the next_target is set to instance->upper which ramps up to maximal cooling device target when the temperature is steadily decreasing.
drivers/thermal/step_wise.c +1 -1
@@ -76,7 +76,7 @@ static unsigned long get_target_state(struct thermal_instance *instance, next_target = instance->upper;break ;case THERMAL_TREND_DROPPING : -if (cur_state == instance->lower) { +if (cur_state <= instance->lower) {if (!throttle) next_target =THERMAL_NO_TARGET ; }else {
Here's the debug output on my board:
[ 21.301211] thermal thermal_zone0: last_temperature=0, current_temperature=51000 [ 21.308803] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=1,throttle=0 [ 21.316248] thermal cooling_device0: cur_state=0 [ 21.320957] thermal cooling_device0: old_target=-1, target=-1 [ 21.326755] thermal cooling_device0: zone0->target=4294967295 [ 21.332544] thermal cooling_device0: set to state 0
[ 34.349747] thermal thermal_zone0: last_temperature=51000, current_temperature=46000 [ 34.357830] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=2,throttle=0 [ 34.365254] thermal cooling_device0: cur_state=0 [ 34.369989] thermal cooling_device0: old_target=-1, target=4 [ 34.375740] thermal cooling_device0: zone0->target=4 [ 34.380867] thermal cooling_device0: set to state 4
Bug: raising the cooling state, despite the temperature dropping.
The .bind() call was
thermal_zone_bind_cooling_device(tz, 0, cdev, 4, 1);
(The intent being that, once the system is above the trip temp, at least a little bit of cooling should be applied, always.)
cur_state = 0 is not equal to lower_state = 1
AFAICT, Lukasz's patch fixes that issue.
Regards.
Greg KH
maintainerQuoted 62 lines · Mason
Hello,
This is my first time requesting inclusion of a patch, please point out any breach of protocol.
I'm using linux-3.14.y and I've run into a bug fixed in later kernel versions:
commit
26bb0e9a1a938ec98ee07aa76533f1a711fba706Author: Lukasz Majewski <[email protected]> Date: Wed Sep 24 10:27:10 2014 +0200thermal:
step_wise: fix: Prevent from binary overflow when trend is droppingIt turns out that some boards can have
instance->lowergreater than 0 and when thermal trend is dropping it results withnext_targetequal to -1.Since the
next_targetis defined as unsigned long it is interpreted as0xFFFFFFFFand larger thaninstance->upper.
As a result thenext_targetis set toinstance->upperwhich ramps up to maximal cooling device target when the temperature is steadily decreasing.Signed-off-by Lukasz Majewski <[email protected]>Signed-off-by Zhang Rui <[email protected]>drivers/thermal/step_wise.c +1
-1@@ -76,7 +76,7 @@ static unsigned long get_target_state(struct thermal_instance *instance, next_target = instance->upper;break ;case THERMAL_TREND_DROPPING : -if (cur_state == instance->lower) { +if (cur_state <= instance->lower) {if (!throttle) next_target =THERMAL_NO_TARGET ; }else {Here's the debug output on my board:
[ 21.301211] thermal thermal_zone0: last_temperature=0, current_temperature=51000 [ 21.308803] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=1,throttle=0 [ 21.316248] thermal cooling_device0: cur_state=0 [ 21.320957] thermal cooling_device0: old_target=-1, target=-1 [ 21.326755] thermal cooling_device0: zone0->target=4294967295 [ 21.332544] thermal cooling_device0: set to state 0[ 34.349747] thermal thermal_zone0: last_temperature=51000, current_temperature=46000 [ 34.357830] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=2,throttle=0 [ 34.365254] thermal cooling_device0: cur_state=0 [ 34.369989] thermal cooling_device0: old_target=-1, target=4 [ 34.375740] thermal cooling_device0: zone0->target=4 [ 34.380867] thermal cooling_device0: set to state 4Bug: raising the cooling state, despite the temperature dropping.
The .bind() call was
Quoted 8 lines
thermal_zone_bind_cooling_device(tz, 0, cdev, 4, 1);(The intent being that, once the system is above the trip temp, at least a little bit of cooling should be applied, always.)
cur_state= 0 is not equal tolower_state= 1AFAICT, Lukasz's patch fixes that issue.
Now queued up, thanks.
greg k-h
Quoted 8 lines · Mason
Hello,
This is my first time requesting inclusion of a patch, please point out any breach of protocol.
I'm using linux-3.14.y and I've run into a bug fixed in later kernel versions:
Thanks, I'm queuing this patch for the 3.16 kernel as well.
Cheers,
--
Lu�s
Quoted 68 lines
commit
26bb0e9a1a938ec98ee07aa76533f1a711fba706Author: Lukasz Majewski <[email protected]> Date: Wed Sep 24 10:27:10 2014 +0200thermal:
step_wise: fix: Prevent from binary overflow when trend is droppingIt turns out that some boards can have
instance->lowergreater than 0 and when thermal trend is dropping it results withnext_targetequal to -1.Since the
next_targetis defined as unsigned long it is interpreted as0xFFFFFFFFand larger thaninstance->upper.
As a result thenext_targetis set toinstance->upperwhich ramps up to maximal cooling device target when the temperature is steadily decreasing.Signed-off-by Lukasz Majewski <[email protected]>Signed-off-by Zhang Rui <[email protected]>drivers/thermal/step_wise.c +1
-1@@ -76,7 +76,7 @@ static unsigned long get_target_state(struct thermal_instance *instance, next_target = instance->upper;break ;case THERMAL_TREND_DROPPING : -if (cur_state == instance->lower) { +if (cur_state <= instance->lower) {if (!throttle) next_target =THERMAL_NO_TARGET ; }else {Here's the debug output on my board:
[ 21.301211] thermal thermal_zone0: last_temperature=0, current_temperature=51000 [ 21.308803] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=1,throttle=0 [ 21.316248] thermal cooling_device0: cur_state=0 [ 21.320957] thermal cooling_device0: old_target=-1, target=-1 [ 21.326755] thermal cooling_device0: zone0->target=4294967295 [ 21.332544] thermal cooling_device0: set to state 0[ 34.349747] thermal thermal_zone0: last_temperature=51000, current_temperature=46000 [ 34.357830] thermal thermal_zone0: Trip0[type=1,temp=70000]:trend=2,throttle=0 [ 34.365254] thermal cooling_device0: cur_state=0 [ 34.369989] thermal cooling_device0: old_target=-1, target=4 [ 34.375740] thermal cooling_device0: zone0->target=4 [ 34.380867] thermal cooling_device0: set to state 4Bug: raising the cooling state, despite the temperature dropping.
The .bind() call was
thermal_zone_bind_cooling_device(tz, 0, cdev, 4, 1);(The intent being that, once the system is above the trip temp, at least a little bit of cooling should be applied, always.)
cur_state= 0 is not equal tolower_state= 1AFAICT, Lukasz's patch fixes that issue.
Regards.
--
To unsubscribe from this list: send the line "unsubscribe stable" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html