i40e: disabling flow control makes XL710 NIC discard all packets

DISCUSSION Martin Weiser 2 participants 3 messages Nov 4, 2015 – Nov 5, 2015

lore
Share & tools
lore
#0 lore raw

Hi Helin,

I have been doing some tests with the current DPDK master to see if the issues we had with performance and statistics have improved. In our own applications we usually disable flow control using the following code:

struct rte_eth_fc_conf fc_conf = { .mode = RTE_FC_NONE }; int ret = rte_eth_dev_flow_ctrl_set(port_id, &fc_conf);

In DPDK 2.1 this did not cause any problems with XL710 NICs but with the current master the NIC will not receive any packets and they are all counted in ierrors and imissed.
The return value of rte_eth_dev_flow_ctrl_set does not indicate an error so it seems like something is going wrong here.

Regards,
Martin

#1 lore raw

Hi Martin

Thank you very much for reporting the issue!
Could you help to add more detailed steps and other information? We will try to reproduce what have seen in our lab, and then debug.

Regards,
Helin

Quoted 24 lines

-----Original Message-----
From: Martin Weiser [mailto:[email protected]]
Sent: Wednesday, November 4, 2015 6:17 PM
To: Zhang, Helin; [email protected]
Subject: i40e: disabling flow control makes XL710 NIC discard all packets

Hi Helin,

I have been doing some tests with the current DPDK master to see if the issues we had with performance and statistics have improved.
In our own applications we usually disable flow control using the following code:

struct rte_eth_fc_conf fc_conf = { .mode = RTE_FC_NONE }; int ret = rte_eth_dev_flow_ctrl_set(port_id, &fc_conf);

In DPDK 2.1 this did not cause any problems with XL710 NICs but with the current master the NIC will not receive any packets and they are all counted in ierrors and imissed.
The return value of rte_eth_dev_flow_ctrl_set does not indicate an error so it seems like something is going wrong here.

Regards,
Martin

#2 lore raw

Hi Helin,

I did some more testing and it seems like the issue is triggered when the 'high_water' and 'low_water' fields of the 'rte_eth_fc_conf' structure are set to 0 (like in my initial code example). The following example does not trigger the issue:

struct rte_eth_fc_conf fc_conf;
rte_eth_dev_flow_ctrl_get(pi, &fc_conf);
fc_conf.mode = RTE_FC_NONE;
rte_eth_dev_flow_ctrl_set(pi, &fc_conf);

But when using the following code all packets will be discarded although the call to rte_eth_dev_flow_ctrl_set does not return an error:

struct rte_eth_fc_conf fc_conf;
rte_eth_dev_flow_ctrl_get(pi, &fc_conf);
fc_conf.mode = RTE_FC_NONE;
fc_conf.low_water = 0;
fc_conf.high_water = 0;
rte_eth_dev_flow_ctrl_set(pi, &fc_conf);

I think the rest of the structure's values should not have any effect as long as flow control is completely disabled by setting the mode to RTE_FC_NONE. At least it did not with DPDK 2.1 or for other NIC types.

Regards,
Martin

Quoted 31 lines · Helin

Hi Martin

Thank you very much for reporting the issue!
Could you help to add more detailed steps and other information? We will try to reproduce what have seen in our lab, and then debug.

Regards,
Helin

Quoted 22 lines

-----Original Message-----
From: Martin Weiser [mailto:[email protected]]
Sent: Wednesday, November 4, 2015 6:17 PM
To: Zhang, Helin; [email protected]
Subject: i40e: disabling flow control makes XL710 NIC discard all packets

Hi Helin,

I have been doing some tests with the current DPDK master to see if the issues we had with performance and statistics have improved.
In our own applications we usually disable flow control using the following code:

struct rte_eth_fc_conf fc_conf = { .mode = RTE_FC_NONE }; int ret = rte_eth_dev_flow_ctrl_set(port_id, &fc_conf);

In DPDK 2.1 this did not cause any problems with XL710 NICs but with the current master the NIC will not receive any packets and they are all counted in ierrors and imissed.
The return value of rte_eth_dev_flow_ctrl_set does not indicate an error so it seems like something is going wrong here.
Regards,
Martin