HVMlite ABI specification DRAFT B + implementation outline
Hello,
I've Cced a bunch of people who have expressed interest in the HVMlite design/implementation, both from a Xen or OS point of view. If you would like to be removed, please say so and I will remove you in further iterations. The same applies if you want to be added to the Cc.
This is an initial draft on the HVMlite design and implementation. I've mixed certain aspects of the design with the implementation, because I think we are quite tied by the implementation possibilities in certain aspects, so not speaking about it would make the document incomplete. I might be wrong on that, so feel free to comment otherwise if you would prefer a different approach.
The document is still not complete. I'm of course not as knowledgeable as some people on the Cc, so please correct me if you think there are mistakes or simply impossible goals.
I think I've managed to integrate all the comments from DRAFT A. I still haven't done a s/HVMlite/PVH/, but I plan to do so once the document is finished and ready to go inside of the Xen tree.
Roger.
---
Xen HVMlite ABI
===============
Boot ABI
--------
Since the Xen entry point into the kernel can be different from the native entry point, a ELFNOTE is used in order to tell the domain builder how to load and jump into the kernel entry point:
ELFNOTE(Xen, XEN_ELFNOTE_PHYS32_ENTRY, .long, xen_start32)
The presence of the XEN_ELFNOTE_PHYS32_ENTRY note indicates that the kernel supports the boot ABI described in this document.
The domain builder shall load the kernel into the guest memory space and jump into the entry point defined at XEN_ELFNOTE_PHYS32_ENTRY with the following machine state:
* ebx: contains the physical memory address where the loader has placed the boot start info structure.
* cr0: bit 0 (PE) must be set. All the other writeable bits are cleared.
* cr4: all bits are cleared.
* cs: must be a 32-bit read/execute code segment with a base of ‘0’ and a limit of ‘0xFFFFFFFF’. The selector value is unspecified.
* ds, es: must be a 32-bit read/write data segment with a base of ‘0’ and a limit of ‘0xFFFFFFFF’. The selector values are all unspecified.
* tr: must be a 32-bit TSS (active) with a base of '0' and a limit of '0x67'.
* eflags: all user settable bits are clear.
All other processor registers and flag bits are unspecified. The OS is in charge of setting up it's own stack, GDT and IDT.
The format of the boot start info structure is the following (pointed to be %ebx):
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578
| | ("xEn3" with the 0x80 bit of the "E" set).
4 +----------------+
| flags | SIF_xxx flags.
8 +----------------+
| cmdline_paddr | Physical address of the command line,
| | a zero-terminated ASCII string.
12 +----------------+
| nr_modules | Number of modules passed to the kernel.
16 +----------------+
| modlist_paddr | Physical address of an array of modules
| | (layout of the structure below).20 +----------------+
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+
| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.
12 +----------------+
| reserved |
16 +----------------+
Other relevant information needed in order to boot a guest kernel (console page address, xenstore event channel...) can be obtained using HVMPARAMS, just like it's done on HVM guests.
The setup of the hypercall page is also performed in the same way as HVM guests, using the hypervisor cpuid leaves and msr ranges.
Hardware description
--------------------
Hardware description can come from two different sources, just like on (PV)HVM guests.
Description of PV devices will always come from xenbus, and in fact xenbus is the only hardware description that is guaranteed to always be provided to HVMlite guests.
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided. The presence of ACPI tables can be detected by finding the RSDP, just like on bare metal.
Non-PV devices exposed to the guest
-----------------------------------
The initial idea was to simply don't provide any emulated devices to a HVMlite guest as the default option. We have however identified certain situations where emulated devices could be interesting, both from a performance and ease of implementation point of view. The following list tries to encompass the different identified scenarios:
* 1. HVMlite with no emulated devices at all
------------------------------------------
This is the current implementation inside of Xen, everything is disabled by default and the guest has access to the PV devices only. This is of course the most secure design because it has the smaller surface of attack.
* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.
* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.
Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
The default model for HVMlite guests is going to be to provide a local APIC together with a minimal set of ACPI tables that accurately match the reality of the container is guest is running on. An administrator should be able to change the default setting using the following tunables that are part of the xl toolstack:
* lapic: default to true. Indicates whether a local APIC is provided.
* ioapic: default to false. Indicates whether an IO APIC is provided (requires lapic set to true).
* acpi: default to true. Indicates whether ACPI tables are provided.
ACPI
----
ACPI tables will be provided to the hardware domain or to unprivileged domains. In the case of unprivileged guests ACPI tables are going to be created by the toolstack and will only contain the set of devices available to the guest, which will at least be the following: local APIC and optionally an IO APIC and passed-through device(s). In order to provide this information from ACPI the following tables are needed as a minimum: RSDT, FADT, MADT and DSDT. If an administrator decides to not provide a local APIC, the MADT table is not going to be provided to the guest OS.
The ACPI_FADT_NO_CMOS_RTC flag in the FADT boot_flags field is going to be used to signal guests that there's no RTC device (the Xen PV wall clock should be used instead). It is likely that this flag is not going to be set for the hardware domain, since it should have access to the RTC present in the host (if there's one). The ACPI_FADT_NO_VGA is also very likely to be set in the same boot_flags FADT field for DomUs in order to signal that there's no VGA adapter present.
Finally the ACPI_FADT_HW_REDUCED is going to be set in the FADT flags field in order to signal that there are no legacy devices: i8259 PIC or i8254 PIT. There's no intention to enable these devices, so it is expected that the hardware-reduced FADT flag is always going to be set.
In the case of the hardware domain, Xen has traditionally passed-through the native ACPI tables to the guest. This is something that of course we still want to do, but in the case of HVMlite Xen will have to make sure that the data passed in the ACPI tables to the hardware domain contain the accurate hardware description. This means that at least certain tables will have to be modified/mangled before being presented to the guest:
* MADT: the number of local APIC entries need to be fixed to match the number of vCPUs available to the guest. The address of the IO APIC(s) also need to be fixed in order to match the emulated ones that we are going to provide.
* DSDT: certain devices reported in the DSDT may not be available to the guest, but since the DSDT is a run-time generated table we cannot fix it. In order to cope with this, a STAO table will be provided that should be able to signal which devices are not available to the hardware domain. This is in line with the Xen/ACPI implementation for ARM.
* MPST, PMTT, SBTT, SRAT and SLIT: won't be initially presented to the guest, until we get our act together on the vNUMA stuff.
NB: there are corner cases that I'm not sure how to solve properly. Currently the hardware domain has some 'hacks' regarding ACPI and Xen. At least I'm aware of the following:
* 1. Reporting CPU PM info back to Xen: this comes from the DSDT table, and since this table is only available to the hardware domain it has to report the PM info back to Xen so that Xen can perform proper PM.
* 2. Doing proper shutdown (S5) requires the usage of a hypercall, which is mixed with native ACPICA code in most OSes. This is awkward and requires the usage of hooks into ACPICA which we have not yet managed to upstream.
* 3. Reporting the PCI devices it finds to the hypervisor: this is not very intrusive in general, so I'm not that pushed to remove it. It's generally easy in any OS to add some kind of hook that's executed every time a PCI device is discovered.
* 4. Report PCI memory-mapped configuration areas to Xen: my opinion regarding this one is the same as (3), it's not really intrusive so I'm not very pushed to remove it.
I would ideally like to get rid of (2) in the list above, since I'm quite sure we are never going to be able to merge the needed hooks into ACPICA. AFAICT Xen should be able to parse the FADT table and find the address of the PM1a and PM1b control registers and trap on access.
(1) is also quite nasty, but I don't see any possible way to get rid of it.
AP startup
----------
AP startup is performed using hypercalls. The following VCPU operations are used in order to bring up secondary vCPUs:
* VCPUOP_initialise is used to set the initial state of the vCPU. The argument passed to the hypercall must be of the type vcpu_hvm_context. See public/hvm/hvm_vcpu.h for the layout of the structure. Note that this hypercall allows starting the vCPU in several modes (16/32/64bits), regardless of the mode the BSP is currently running on.
* VCPUOP_up is used to launch the vCPU once the initial state has been set using VCPUOP_initialise.
* VCPUOP_down is used to bring down a vCPU.
* VCPUOP_is_up is used to scan the number of available vCPUs.
Additionally, if a local APIC is available CPU bringup can also be performed using the hardware native AP startup sequence (IPIs). In this case the hypercall interface will still be provided, as a faster and more convenient way of starting APs.
MMIO mapping
------------
For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
For the hardware domain initial direct MMIO mappings will be set for the following regions:
NOTE: ranges are defined using memory addresses, not pages.
* [0x0, 0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.
* [0xF00000, 0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.
* ACPI memory areas: regions with type E820_ACPI or E820_NVS will be mapped 1:1 to the guest physical memory map. There are going to be exceptions if Xen has to modify the tables before presenting them to the guest.
* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the PHYSDEVOP_pci_mmcfg_reserved hypercall Xen will also all guest access to them.
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction. In order to have the BARs of PCI devices properly mapped the hardware domain needs to call the PHYSDEVOP_pci_device_add hypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.
Xen HVMlite implementation plan
===============================
This is of course not part of the ABI, but I guess it makes sense to add it here in order to be able to more easily split the tasks required in order to make the proposed implementation above a reality. I've tried to split the tasks into smaller sub-tasks when possible.
DomU
----
1. Initial HVMlite implementation based on a HVM guest: no emulated devices will be provided, interface exactly the same as a PVH guest except for the boot ABI.
2. Provide ACPI tables to HVMlite guests: the initial set of provided tables will be: RSDT, FADT, MADT (iff local APIC is enabled).
3. Enable the local APIC by default for HVMlite guests.
4. Provide options to xl/libxl in order to allow admins to select the presence of a local APIC and IO APIC to HVMlite guests.
5. Implement an emulated PCI Root Complex inside of Xen.
6. Provide a DSDT table to HVMlite guests in order to signal the presence of PCI-passthrough devices.
IMHO, we should focus on (2) and (3) at the moment, and (4) is quite trivial once those two are in place. (5) and (6) should be implemented once HVMlite hardware domains are functional.
When implementing (2) it would be good to place the ACPI related code in a place that's accessible from libxl, hvmloader and Xen itself, in order to reduce code duplication. hvmloader already has most if not all the required code in order to build the tables that are needed for HVMlite DomU.
Dom0
----
1. Add a new Dom0 builder specific for HVM-like domains. PV domains have different requirements and sharing the same Dom0 domain builder only makes the code for both cases much harder to read and disentangle.
2. Implement the code required in order to mangle/modify the ACPI tables provided to Dom0, so that it matches the reality of the container provided to Dom0.
3. Allow HVM Dom0 to use PHYSDEVOP_pci_mmcfg_reserved and PHYSDEVOP_pci_device_add and make sure these hypercalls add the proper MMIO mappings.
4. Do the necessary wiring so that interrupts from physical devices are received by Dom0 using the emulated interrupt controllers (local and IO APICs).
This plan is not as detailed as the DomU one, since the Dom0 work is not as advanced as the DomU work, and is also tied to the DomU implementation. I have an initial implementation for (1), and will continue working on it.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 8 lines · Roger Pau Monné
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction. In order to have the BARs of PCI devices properly mapped the hardware domain needs to call the
PHYSDEVOP_pci_device_addhypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.
We also want to use PHYSDEVOP_pci_device_add because that's how we pass device's PXM information to the hypervisor.
Quoted 29 lines
Xen HVMlite implementation plan
===============================This is of course not part of the ABI, but I guess it makes sense to add it here in order to be able to more easily split the tasks required in order to make the proposed implementation above a reality. I've tried to split the tasks into smaller sub-tasks when possible.
DomU
----1. Initial HVMlite implementation based on a HVM guest: no emulated devices will be provided, interface exactly the same as a PVH guest except for the boot ABI.
2. Provide ACPI tables to HVMlite guests: the initial set of provided tables will be: RSDT, FADT, MADT (iff local APIC is enabled).
3. Enable the local APIC by default for HVMlite guests.
4. Provide options to xl/libxl in order to allow admins to select the presence of a local APIC and IO APIC to HVMlite guests.
5. Implement an emulated PCI Root Complex inside of Xen.
6. Provide a DSDT table to HVMlite guests in order to signal the presence of PCI-passthrough devices.
Quoted 8 lines
IMHO, we should focus on (2) and (3) at the moment, and (4) is quite trivial once those two are in place. (5) and (6) should be implemented once HVMlite hardware domains are functional.
When implementing (2) it would be good to place the ACPI related code in a place that's accessible from libxl, hvmloader and Xen itself, in order to reduce code duplication. hvmloader already has most if not all the required code in order to build the tables that are needed for HVMlite DomU.
Since I started poking at ACPI code in hvmloader anyway I can take a stab at (2).
-boris
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 47 lines · Roger Pau Monné
The format of the boot start info structure is the following (pointed to be %ebx):
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578 | | ("xEn3" with the 0x80 bit of the "E" set). 4 +----------------+ | flags | SIF_xxx flags. 8 +----------------+ | cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 12 +----------------+ | nr_modules | Number of modules passed to the kernel. 16 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).20 +----------------+
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.12 +----------------+
| reserved |
16 +----------------+Other relevant information needed in order to boot a guest kernel (console page address, xenstore event channel...) can be obtained using HVMPARAMS, just like it's done on HVM guests.
The setup of the hypercall page is also performed in the same way as HVM guests, using the hypervisor cpuid leaves and msr ranges.
Hardware description
--------------------Hardware description can come from two different sources, just like on (PV)HVM guests.
Quoted 8 lines
Description of PV devices will always come from xenbus, and in fact xenbus is the only hardware description that is guaranteed to always be provided to HVMlite guests.
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided. The presence of ACPI tables can be detected by finding the RSDP, just like on bare metal.
As we are extending the base structure, why not have an RSDP paddr in it as well? This avoids the need to scan RAM, and also serves as an indication of "No ACPI".
Quoted 37 lines
Non-PV devices exposed to the guest
-----------------------------------The initial idea was to simply don't provide any emulated devices to a HVMlite guest as the default option. We have however identified certain situations where emulated devices could be interesting, both from a performance and ease of implementation point of view. The following list tries to encompass the different identified scenarios:
* 1. HVMlite with no emulated devices at all
------------------------------------------
This is the current implementation inside of Xen, everything is disabled by default and the guest has access to the PV devices only. This is of course the most secure design because it has the smaller surface of attack.* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.
Quoted 7 lines
Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
The default model for HVMlite guests is going to be to provide a local APIC together with a minimal set of ACPI tables that accurately match the reality of the container is guest is running on.
This statement is contrary to option 1 above, which states that all emulation is disabled.
FWIW, I think there needs to be a 4th option, inbetween current 1 and 2, which is HVMLite + LAPIC. This is then the default HVMLite ABI, and is not passthrough-capable.
Quoted 20 lines
An administrator should be able to change
the default setting using the following tunables that are part of the xl toolstack:* lapic: default to true. Indicates whether a local APIC is provided.
* ioapic: default to false. Indicates whether an IO APIC is provided (requires lapic set to true).
* acpi: default to true. Indicates whether ACPI tables are provided.<snip>
MMIO mapping
------------For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
Quoted 4 lines
For the hardware domain initial direct MMIO mappings will be set for the following regions:
NOTE: ranges are defined using memory addresses, not pages.
I would preface this with "where applicable". Non-legacy boots are unlikely to have anything interesting in the first 1MB.
Quoted 20 lines
* [
0x0,0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.* [
0xF00000,0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.* ACPI memory areas: regions with type
E820_ACPIorE820_NVSwill be mapped 1:1 to the guest physical memory map. There are going to be exceptions if Xen has to modify the tables before presenting them to the guest.* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.
Quoted 2 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction.
Xen requires no dom0 interaction to find all information like this for devices in segment 0 (i.e. all current hardware). Segments other than 0 may have their MMCONF regions expressed in AML only.
The reason this is all awkward in Xen is that PCI devices were hacked in as second-class citizens when IOMMU support was added. This is a purely a Xen software issue which needs undoing.
Quoted 8 lines
In order to have
the BARs of PCI devices properly mapped the hardware domain needs to call thePHYSDEVOP_pci_device_addhypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 52 lines · Roger Pau Monné
Quoted 51 lines
The format of the boot start info structure is the following (pointed to be %ebx):
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578 | | ("xEn3" with the 0x80 bit of the "E" set). 4 +----------------+ | flags | SIF_xxx flags. 8 +----------------+ | cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 12 +----------------+ | nr_modules | Number of modules passed to the kernel. 16 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).20 +----------------+
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.12 +----------------+
| reserved |
16 +----------------+Other relevant information needed in order to boot a guest kernel (console page address, xenstore event channel...) can be obtained using HVMPARAMS, just like it's done on HVM guests.
The setup of the hypercall page is also performed in the same way as HVM guests, using the hypervisor cpuid leaves and msr ranges.
Hardware description
--------------------Hardware description can come from two different sources, just like on (PV)HVM guests.
Description of PV devices will always come from xenbus, and in fact xenbus is the only hardware description that is guaranteed to always be provided to HVMlite guests.
Quoted 8 lines
Quoted 4 lines
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided. The presence of ACPI tables can be detected by finding the RSDP, just like on bare metal.
As we are extending the base structure, why not have an RSDP paddr in it as well? This avoids the need to scan RAM, and also serves as an indication of "No ACPI".
Right, this seems fine to me. I can send a patch later to expand the structure unless anyone else complains.
Quoted 46 lines
Quoted 38 lines
Non-PV devices exposed to the guest
-----------------------------------The initial idea was to simply don't provide any emulated devices to a HVMlite guest as the default option. We have however identified certain situations where emulated devices could be interesting, both from a performance and ease of implementation point of view. The following list tries to encompass the different identified scenarios:
* 1. HVMlite with no emulated devices at all
------------------------------------------
This is the current implementation inside of Xen, everything is disabled by default and the guest has access to the PV devices only. This is of course the most secure design because it has the smaller surface of attack.* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.Quoted 7 lines
Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
The default model for HVMlite guests is going to be to provide a local APIC together with a minimal set of ACPI tables that accurately match the reality of the container is guest is running on.
Quoted 6 lines
This statement is contrary to option 1 above, which states that all emulation is disabled.
FWIW, I think there needs to be a 4th option, inbetween current 1 and 2, which is HVMLite + LAPIC. This is then the default HVMLite ABI, and is not passthrough-capable.
Right, I think this makes sense because (2) is not exactly the same as it requires the presence of a PCI root complex.
Quoted 20 lines
Quoted 20 lines
An administrator should be able to change
the default setting using the following tunables that are part of the xl toolstack:* lapic: default to true. Indicates whether a local APIC is provided.
* ioapic: default to false. Indicates whether an IO APIC is provided (requires lapic set to true).
* acpi: default to true. Indicates whether ACPI tables are provided.<snip>
MMIO mapping
------------For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
Quoted 7 lines
Quoted 4 lines
For the hardware domain initial direct MMIO mappings will be set for the following regions:
NOTE: ranges are defined using memory addresses, not pages.
I would preface this with "where applicable". Non-legacy boots are unlikely to have anything interesting in the first 1MB.
Yes, I've only taken legacy (BIOS) boot into account here. I'm not familiar with UEFI, so I'm not really sure how different it is, or which memory regions should be mapped into the guest physmap in that case. I should have made this explicit by adding a title, like:
Legacy BIOS boot
----------------
Quoted 21 lines
Quoted 21 lines
* [
0x0,0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.* [
0xF00000,0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.* ACPI memory areas: regions with type
E820_ACPIorE820_NVSwill be mapped 1:1 to the guest physical memory map. There are going to be exceptions if Xen has to modify the tables before presenting them to the guest.* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.
Quoted 6 lines
Quoted 2 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction.
Xen requires no dom0 interaction to find all information like this for devices in segment 0 (i.e. all current hardware). Segments other than 0 may have their MMCONF regions expressed in AML only.
Thanks for the comments, please bear with me. I think we are mixing two things here, one is the MMCFG areas, and the other one are the BARs of each PCI device.
AFAIK MMCFG areas are described in the 'MCFG' ACPI table, which is static and Xen should be able to parse on it's own. Then I'm not sure why PHYSDEVOP_pci_mmcfg_reserved is needed at all.
Then for BARs you need to know the specific PCI devices, which are enumerated in the DSDT or similar ACPI tables, which are not static, and thus cannot be parsed by Xen. We could do a brute force scan of the whole PCI bus using the config registers, but that seems hacky. And as Boris said we need to keep the usage of PHYSDEVOP_pci_device_add in order to notify Xen of the PXM information.
If we indeed have all the information about the BARs (position and size) we could pre-map them 1:1 before creating the hardware domain, and thus no modifications will be needed to the PHYSDEVOP_pci_device_add hypercall.
Roger.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 19 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 12:58, <[email protected]> wrote:
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 10 lines · Roger Pau Monné
Quoted 9 lines
* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.Quoted 6 lines
Quoted 2 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction.
Xen requires no dom0 interaction to find all information like this for devices in segment 0 (i.e. all current hardware). Segments other than 0 may have their MMCONF regions expressed in AML only.
Quoted 7 lines
Thanks for the comments, please bear with me. I think we are mixing two things here, one is the MMCFG areas, and the other one are the BARs of each PCI device.
AFAIK MMCFG areas are described in the 'MCFG' ACPI table, which is static and Xen should be able to parse on it's own. Then I'm not sure why
PHYSDEVOP_pci_mmcfg_reservedis needed at all.
Because there are safety nets: Xen and Linux consult the memory map to determine whether actually using what the firmware say is an MMCFG area is actually safe. Linux in addition checks ACPI tables, and this is what Xen can't do (as it require an AML interpreter), hence the hypercall to inform the hypervisor.
Quoted 6 lines
Then for BARs you need to know the specific PCI devices, which are enumerated in the DSDT or similar ACPI tables, which are not static, and thus cannot be parsed by Xen. We could do a brute force scan of the whole PCI bus using the config registers, but that seems hacky. And as Boris said we need to keep the usage of
PHYSDEVOP_pci_device_addin order to notify Xen of the PXM information.
We can only be sure to have access to segment 0 at boot time. Other segments may be accessible via MMCFG only, and whether we can safely use the respective MMCFG we won't know - see above - early enough. That's also the reason why today we do a brute force scan only on segment 0.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
El 9/2/16 a les 13:10, Jan Beulich ha escrit:
Quoted 27 lines
Quoted 19 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 12:58, <[email protected]> wrote:
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 10 lines · Roger Pau Monné
Quoted 9 lines
* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.Quoted 6 lines
Quoted 2 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction.
Xen requires no dom0 interaction to find all information like this for devices in segment 0 (i.e. all current hardware). Segments other than 0 may have their MMCONF regions expressed in AML only.
Quoted 7 lines
Thanks for the comments, please bear with me. I think we are mixing two things here, one is the MMCFG areas, and the other one are the BARs of each PCI device.
AFAIK MMCFG areas are described in the 'MCFG' ACPI table, which is static and Xen should be able to parse on it's own. Then I'm not sure why
PHYSDEVOP_pci_mmcfg_reservedis needed at all.
Quoted 5 lines
Because there are safety nets: Xen and Linux consult the memory map to determine whether actually using what the firmware say is an MMCFG area is actually safe. Linux in addition checks ACPI tables, and this is what Xen can't do (as it require an AML interpreter), hence the hypercall to inform the hypervisor.
Hm, I guess I'm overlooking something, but I think Xen checks the ACPI tables, see xen/arch/x86/x86_64/mmconfig-shared.c:400:
if (pci_mmcfg_check_hostbridge()) {
unsigned int i;
pci_mmcfg_arch_init();
for (i = 0; i < pci_mmcfg_config_num; ++i)
if (pci_mmcfg_arch_enable(i))
valid = 0;
} else {
acpi_table_parse(ACPI_SIG_MCFG, acpi_parse_mcfg);
pci_mmcfg_arch_init();
valid = pci_mmcfg_reject_broken();
}Which AFAICT suggests that Xen is indeed able to parse the 'MCFG' table, which contains the list of MMCFG regions on the system. Is there any other ACPI table where this information is reported that I'm missing?
This would suggest then that the hypercall is no longer needed.
Quoted 7 lines
Quoted 6 lines
Then for BARs you need to know the specific PCI devices, which are enumerated in the DSDT or similar ACPI tables, which are not static, and thus cannot be parsed by Xen. We could do a brute force scan of the whole PCI bus using the config registers, but that seems hacky. And as Boris said we need to keep the usage of
PHYSDEVOP_pci_device_addin order to notify Xen of the PXM information.
Quoted 5 lines
We can only be sure to have access to segment 0 at boot time. Other segments may be accessible via MMCFG only, and whether we can safely use the respective MMCFG we won't know - see above - early enough. That's also the reason why today we do a brute force scan only on segment 0.
Andrew suggested that all current hardware only uses segment 0, so it seems like covering segment 0 is all that's needed for now. Are OSes already capable of dealing with segments different than 0 that only support MMCFG accesses?
And in which case, if a segment != 0 appears, and it only supports MMCFG accesses, the MCFG table should contain an entry for this area, which should allow us to properly scan it.
Roger.
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 53 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 14:00, <[email protected]> wrote:
El 9/2/16 a les 13:10, Jan Beulich ha escrit:
Quoted 4 lines
Quoted 4 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 12:58, <[email protected]> wrote:
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 2 lines · Roger Pau Monné
Quoted 1 line
* PCI Express MMCFG: if Xen is able to identify any of these regions at
boot
Quoted 2 lines
Quoted 2 lines
Quoted 2 lines
Quoted 2 lines
time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses
to
Quoted 21 lines
Quoted 13 lines
Quoted 6 lines
Quoted 6 lines
those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.Quoted 6 lines
Quoted 2 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction.
Xen requires no dom0 interaction to find all information like this for devices in segment 0 (i.e. all current hardware). Segments other than 0 may have their MMCONF regions expressed in AML only.
Quoted 7 lines
Thanks for the comments, please bear with me. I think we are mixing two things here, one is the MMCFG areas, and the other one are the BARs of each PCI device.
AFAIK MMCFG areas are described in the 'MCFG' ACPI table, which is static and Xen should be able to parse on it's own. Then I'm not sure why
PHYSDEVOP_pci_mmcfg_reservedis needed at all.Quoted 5 lines
Because there are safety nets: Xen and Linux consult the memory map to determine whether actually using what the firmware say is an MMCFG area is actually safe. Linux in addition checks ACPI tables, and this is what Xen can't do (as it require an AML interpreter), hence the hypercall to inform the hypervisor.
Hm, I guess I'm overlooking something, but I think Xen checks the ACPI tables, see
xen/arch/x86/x86_64/mmconfig-shared.c:400:if (pci_mmcfg_check_hostbridge()) { unsigned int i; pci_mmcfg_arch_init(); for (i = 0; i < pci_mmcfg_config_num; ++i) if (pci_mmcfg_arch_enable(i)) valid = 0; } else { acpi_table_parse(ACPI_SIG_MCFG, acpi_parse_mcfg); pci_mmcfg_arch_init(); valid = pci_mmcfg_reject_broken(); }
Quoted 3 lines
Which AFAICT suggests that Xen is indeed able to parse the 'MCFG' table, which contains the list of MMCFG regions on the system. Is there any other ACPI table where this information is reported that I'm missing?
You didn't read my reply carefully enough: I didn't say Xen can't parse these tables. What I said is that Xen isn't by itself in the position to do sanity checks that have proven necessary. Hence ...
Quoted 1 line
This would suggest then that the hypercall is no longer needed.
... it's needed - see Linux'es is_mmconf_reserved() which checks both E820 and data read from DSDT (and maybe SSDT). Also please don't forget about the hotplug case, where _CBA methods need evaluation in order to obtain address information.
Quoted 13 lines
Quoted 7 lines
Quoted 6 lines
Then for BARs you need to know the specific PCI devices, which are enumerated in the DSDT or similar ACPI tables, which are not static, and thus cannot be parsed by Xen. We could do a brute force scan of the whole PCI bus using the config registers, but that seems hacky. And as Boris said we need to keep the usage of
PHYSDEVOP_pci_device_addin order to notify Xen of the PXM information.Quoted 5 lines
We can only be sure to have access to segment 0 at boot time. Other segments may be accessible via MMCFG only, and whether we can safely use the respective MMCFG we won't know - see above - early enough. That's also the reason why today we do a brute force scan only on segment 0.
Quoted 4 lines
Andrew suggested that all current hardware only uses segment 0, so it seems like covering segment 0 is all that's needed for now. Are OSes already capable of dealing with segments different than 0 that only support MMCFG accesses?
Of course - Linux for example. I've actually seen Linux (and Xen) run on a system with multiple segments.
Quoted 3 lines
And in which case, if a segment != 0 appears, and it only supports MMCFG accesses, the MCFG table should contain an entry for this area, which should allow us to properly scan it.
See above.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
El 9/2/16 a les 14:41, Jan Beulich ha escrit:
Quoted 17 lines
Quoted 17 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 14:00, <[email protected]> wrote:
Hm, I guess I'm overlooking something, but I think Xen checks the ACPI tables, see
xen/arch/x86/x86_64/mmconfig-shared.c:400:if (pci_mmcfg_check_hostbridge()) { unsigned int i; pci_mmcfg_arch_init(); for (i = 0; i < pci_mmcfg_config_num; ++i) if (pci_mmcfg_arch_enable(i)) valid = 0; } else { acpi_table_parse(ACPI_SIG_MCFG, acpi_parse_mcfg); pci_mmcfg_arch_init(); valid = pci_mmcfg_reject_broken(); }
Quoted 7 lines
Quoted 3 lines
Which AFAICT suggests that Xen is indeed able to parse the 'MCFG' table, which contains the list of MMCFG regions on the system. Is there any other ACPI table where this information is reported that I'm missing?
You didn't read my reply carefully enough: I didn't say Xen can't parse these tables. What I said is that Xen isn't by itself in the position to do sanity checks that have proven necessary. Hence ...
Sorry, Ack, AFAICT FreeBSD is much more naive in this aspect and blindly trusts what the ACPI MCFG table contains (or at least it seems to me that way).
I'm not going to argue since you say that this has proven necessary, but are this kind of broken systems still around? PVH/HVMlite requires recent hardware in order to run, so maybe things have improved since this was implemented.
Quoted 6 lines
Quoted 1 line
This would suggest then that the hypercall is no longer needed.
... it's needed - see Linux'es
is_mmconf_reserved()which checks both E820 and data read from DSDT (and maybe SSDT). Also please don't forget about the hotplug case, where_CBAmethods need evaluation in order to obtain address information.
Right, _CBA methods report the ECAM space, and are the only way to get this information in the hotplug case I guess.
Quoted 13 lines
Quoted 13 lines
Quoted 12 lines
Quoted 6 lines
Then for BARs you need to know the specific PCI devices, which are enumerated in the DSDT or similar ACPI tables, which are not static, and thus cannot be parsed by Xen. We could do a brute force scan of the whole PCI bus using the config registers, but that seems hacky. And as Boris said we need to keep the usage of
PHYSDEVOP_pci_device_addin order to notify Xen of the PXM information.We can only be sure to have access to segment 0 at boot time. Other segments may be accessible via MMCFG only, and whether we can safely use the respective MMCFG we won't know - see above - early enough. That's also the reason why today we do a brute force scan only on segment 0.
Quoted 11 lines
Quoted 4 lines
Andrew suggested that all current hardware only uses segment 0, so it seems like covering segment 0 is all that's needed for now. Are OSes already capable of dealing with segments different than 0 that only support MMCFG accesses?
Of course - Linux for example. I've actually seen Linux (and Xen) run on a system with multiple segments.
Quoted 3 lines
And in which case, if a segment != 0 appears, and it only supports MMCFG accesses, the MCFG table should contain an entry for this area, which should allow us to properly scan it.
Right, I wasn't specially trilled to remove these two PHYSDEV hypercalls anyway, they are not very intrusive IMHO. We still need to figure out how to do MMIO mapping of BARs however. We can continue the discussion about MMIO mappings on your other reply to the ABI <[email protected]>.
Roger.
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 17:32, <[email protected]> wrote:
El 9/2/16 a les 14:41, Jan Beulich ha escrit:
Quoted 17 lines
Quoted 17 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 14:00, <[email protected]> wrote:
Hm, I guess I'm overlooking something, but I think Xen checks the ACPI tables, see
xen/arch/x86/x86_64/mmconfig-shared.c:400:if (pci_mmcfg_check_hostbridge()) { unsigned int i; pci_mmcfg_arch_init(); for (i = 0; i < pci_mmcfg_config_num; ++i) if (pci_mmcfg_arch_enable(i)) valid = 0; } else { acpi_table_parse(ACPI_SIG_MCFG, acpi_parse_mcfg); pci_mmcfg_arch_init(); valid = pci_mmcfg_reject_broken(); }Quoted 7 lines
Quoted 3 lines
Which AFAICT suggests that Xen is indeed able to parse the 'MCFG' table, which contains the list of MMCFG regions on the system. Is there any other ACPI table where this information is reported that I'm missing?
You didn't read my reply carefully enough: I didn't say Xen can't parse these tables. What I said is that Xen isn't by itself in the position to do sanity checks that have proven necessary. Hence ...
Quoted 8 lines
Sorry, Ack, AFAICT FreeBSD is much more naive in this aspect and blindly trusts what the ACPI MCFG table contains (or at least it seems to me that way).
I'm not going to argue since you say that this has proven necessary, but are this kind of broken systems still around? PVH/HVMlite requires recent hardware in order to run, so maybe things have improved since this was implemented.
Let me not get started on the quality of memory maps various vendors' UEFI implementations provide.
Jan
Quoted 7 lines · Roger Pau Monné
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 6 lines · Roger Pau Monné
Quoted 5 lines
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided. The presence of ACPI tables can be detected by finding the RSDP, just like on bare metal.
Quoted 6 lines
Quoted 3 lines
As we are extending the base structure, why not have an RSDP paddr in it as well? This avoids the need to scan RAM, and also serves as an indication of "No ACPI".
Right, this seems fine to me. I can send a patch later to expand the structure unless anyone else complains.
Isn't scanning memory the standard procedure for finding RSDP? Even if we provide the address, guests will still search the memory (or is it just Linux that does that?)
-boris
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 15 lines · Boris Ostrovsky
Quoted 14 lines · Roger Pau Monné
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 13 lines · Roger Pau Monné
Quoted 8 lines
Description of physical hardware devices will always come from ACPI, in the
absence of any physical hardware device no ACPI tables will be provided. The
presence of ACPI tables can be detected by finding the RSDP, just like on
bare metal.As we are extending the base structure, why not have an RSDP paddr in it
as well? This avoids the need to scan RAM, and also serves as an indication of "No ACPI".
Quoted 5 lines
Quoted 3 lines
Right, this seems fine to me. I can send a patch later to expand the structure unless anyone else complains.
Isn't scanning memory the standard procedure for finding RSDP?
For BIOS boot, yes. For EFI, not necessarily.
Quoted 2 lines
Even if we provide the address, guests will still search the memory (or is it just Linux that does that?)
A suitably enlightened guest need not scan memory if it is has a direct pointer to the ACPI tables. A guest might still scan memory, but all it is doing is wasting time.
~Andrew
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 12 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 15:36, <[email protected]> wrote:
Quoted 10 lines · Roger Pau Monné
El 9/2/16 a les 11:56, Andrew Cooper ha escrit:
Quoted 9 lines · Roger Pau Monné
Quoted 5 lines
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided. The presence of ACPI tables can be detected by finding the RSDP, just like on bare metal.
As we are extending the base structure, why not have an RSDP paddr in it as well? This avoids the need to scan RAM, and also serves as an indication of "No ACPI".
Quoted 7 lines
Quoted 3 lines
Right, this seems fine to me. I can send a patch later to expand the structure unless anyone else complains.
Isn't scanning memory the standard procedure for finding RSDP? Even if we provide the address, guests will still search the memory (or is it just Linux that does that?)
Not with e.g. EFI, so there's a precedent of avoiding that (legacy) scan.
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 27 lines
Quoted 1 line
Quoted 1 line · On 08.02.16 at 20:03, <[email protected]> wrote:
Boot ABI
--------Since the Xen entry point into the kernel can be different from the native entry point, a
ELFNOTEis used in order to tell the domain builder how to load and jump into the kernel entry point:
ELFNOTE(Xen, XEN_ELFNOTE_PHYS32_ENTRY, .long, xen_start32)The presence of the
XEN_ELFNOTE_PHYS32_ENTRYnote indicates that the kernel supports the boot ABI described in this document.The domain builder shall load the kernel into the guest memory space and jump into the entry point defined at
XEN_ELFNOTE_PHYS32_ENTRYwith the following machine state:*
ebx: contains the physical memory address where the loader has placed the boot start info structure.*
cr0: bit 0 (PE) must be set. All the other writeable bits are cleared.*
cr4: all bits are cleared.*
cs: must be a 32-bit read/execute code segment with a base of ‘0’ and a limit of ‘0xFFFFFFFF’. The selector value is unspecified.
Quoted 6 lines
*
ds,es: must be a 32-bit read/write data segment with a base of ‘0’ and a limit of ‘0xFFFFFFFF’. The selector values are all unspecified.*
tr: must be a 32-bit TSS (active) with a base of '0' and a limit of '0x67'.*
eflags: all user settable bits are clear.
The word "user" here can be mistaken. Perhaps better "all modifiable bits"?
Quoted 2 lines
All other processor registers and flag bits are unspecified. The OS is in charge of setting up it's own stack, GDT and IDT.
The "flag bits" part should now probably be dropped?
Quoted 2 lines
The format of the boot start info structure is the following (pointed to be %ebx):
"... by %ebx"
Quoted 16 lines
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578 | | ("xEn3" with the 0x80 bit of the "E" set). 4 +----------------+ | flags | SIF_xxx flags. 8 +----------------+ | cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 12 +----------------+ | nr_modules | Number of modules passed to the kernel. 16 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).
Quoted 1 line
20 +----------------+
There having been talk about extending the structure, I think we need some indicator that the consumer can use to know which fields are present. I.e. either a version field, another flags one, or a size one.
Quoted 7 lines
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+
Quoted 5 lines
| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.12 +----------------+
| reserved |
16 +----------------+
I've been thinking about this on draft A already: Do we really want to paint ourselves into the corner of not supporting >4Gb modules, by limiting their addresses and sizes to 32 bits?
Quoted 7 lines
Hardware description
--------------------Hardware description can come from two different sources, just like on (PV)HVM
guests.
Quoted 6 lines
Description of PV devices will always come from xenbus, and in fact xenbus is the only hardware description that is guaranteed to always be provided to HVMlite guests.
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided.
This seems too strict: How about "in the absence of any physical hardware device ACPI tables may not be provided"?
Quoted 10 lines
Non-PV devices exposed to the guest
-----------------------------------The initial idea was to simply don't provide any emulated devices to a HVMlite
guest as the default option. We have however identified certain situations where emulated devices could be interesting, both from a performance and ease of implementation point of view. The following list tries to encompass the different identified scenarios:
Quoted 5 lines
* 1. HVMlite with no emulated devices at all
------------------------------------------
This is the current implementation inside of Xen, everything is disabled by default and the guest has access to the PV devices only. This is of course the most secure design because it has the smaller surface of attack.
smallest?
Quoted 11 lines
* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.
Are you reasonably convinced that the absence of an IO-APIC won't, with LAPICs present, cause more confusion than aid to the OSes wanting to adopt PVHv2?
Quoted 9 lines
* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.
Quoted 3 lines
Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
Do you really mean "*always*"? What about a system without IO-APIC? Would you mean to emulate one there for no reason?
Also I think you should say "the usage of many PHYSDEV operations", because - as we've already pointed out - some are unavoidable.
Quoted 20 lines
ACPI
----ACPI tables will be provided to the hardware domain or to unprivileged domains. In the case of unprivileged guests ACPI tables are going to be created by the toolstack and will only contain the set of devices available to the guest, which will at least be the following: local APIC and optionally an IO APIC and passed-through device(s). In order to provide this information from ACPI the following tables are needed as a minimum: RSDT, FADT, MADT and DSDT. If an administrator decides to not provide a local APIC, the MADT table is not going to be provided to the guest OS.
The
ACPI_FADT_NO_CMOS_RTCflag in the FADTboot_flagsfield is going to be used to signal guests that there's no RTC device (the Xen PV wall clock should be used instead). It is likely that this flag is not going to be set for the hardware domain, since it should have access to the RTC present in the host (if there's one). TheACPI_FADT_NO_VGAis also very likely to be set in the sameboot_flagsFADT field for DomUs in order to signal that there's no VGA adapter present.
Quoted 4 lines
Finally the
ACPI_FADT_HW_REDUCEDis going to be set in the FADT flags field in order to signal that there are no legacy devices: i8259 PIC or i8254 PIT. There's no intention to enable these devices, so it is expected that the hardware-reduced FADT flag is always going to be set.
We'll need to be absolutely certain that use of this flag doesn't carry any further implications.
Quoted 13 lines
In the case of the hardware domain, Xen has traditionally passed-through the native ACPI tables to the guest. This is something that of course we still want to do, but in the case of HVMlite Xen will have to make sure that the data passed in the ACPI tables to the hardware domain contain the accurate
hardware description. This means that at least certain tables will have to be modified/mangled before being presented to the guest:* MADT: the number of local APIC entries need to be fixed to match the number of vCPUs available to the guest. The address of the IO APIC(s) also need to be fixed in order to match the emulated ones that we are going to provide.
Quoted 5 lines
* DSDT: certain devices reported in the DSDT may not be available to the guest, but since the DSDT is a run-time generated table we cannot fix it. In order to cope with this, a STAO table will be provided that should be able to signal which devices are not available to the hardware domain. This is in line with the Xen/ACPI implementation for ARM.
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
Quoted 10 lines
NB: there are corner cases that I'm not sure how to solve properly. Currently the hardware domain has some 'hacks' regarding ACPI and Xen. At least I'm aware of the following:
* 1. Reporting CPU PM info back to Xen: this comes from the DSDT table, and since this table is only available to the hardware domain it has to report the PM info back to Xen so that Xen can perform proper PM.
* 2. Doing proper shutdown (S5) requires the usage of a hypercall, which is mixed with native ACPICA code in most OSes. This is awkward and requires the usage of hooks into ACPICA which we have not yet managed to upstream.
Iirc shutdown doesn't require any custom patches anymore in Linux.
Quoted 7 lines
* 3. Reporting the PCI devices it finds to the hypervisor: this is not very intrusive in general, so I'm not that pushed to remove it. It's generally easy in any OS to add some kind of hook that's executed every time a PCI device is discovered.
* 4. Report PCI memory-mapped configuration areas to Xen: my opinion regarding this one is the same as (3), it's not really intrusive so I'm not very pushed to remove it.
As said in another reply - for both of these, we just can't remove the reporting to Xen.
Quoted 12 lines
MMIO mapping
------------For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
For the hardware domain initial direct MMIO mappings will be set for the following regions:
Quoted 7 lines
NOTE: ranges are defined using memory addresses, not pages.
* [
0x0,0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.* [
0xF00000,0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.
When have you last seen a machine with a hole right below the 16Mb boundary?
Quoted 4 lines
* ACPI memory areas: regions with type
E820_ACPIorE820_NVSwill be mapped 1:1 to the guest physical memory map. There are going to be exceptions if Xen has to modify the tables before presenting them to the guest.
Quoted 8 lines
* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.
s/all guest/allow Dom0/ in this last sentence?
Quoted 7 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction. In order to have the BARs of PCI devices properly mapped the hardware domain needs to call the
PHYSDEVOP_pci_device_addhypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.
I'm not sure this can work, as it imposes restrictions on the ordering of operations internal of the Dom0 OS: Successfully having probed for a PCI device (and hence reporting its presence to Xen) doesn't imply its BARs have already got set up. Together with the possibility of the OS re-assigning BARs I think we will actually need another hypercall, or the same device-add hypercall may need to be issued more than once per device (i.e. also every time any BAR assignment got changed).
Jan
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel
Quoted 19 lines · Jan Beulich
Quoted 13 lines
In the case of the hardware domain, Xen has traditionally passed-through the native ACPI tables to the guest. This is something that of course we still want to do, but in the case of HVMlite Xen will have to make sure that the data passed in the ACPI tables to the hardware domain contain the accurate
hardware description. This means that at least certain tables will have to be modified/mangled before being presented to the guest:* MADT: the number of local APIC entries need to be fixed to match the number of vCPUs available to the guest. The address of the IO APIC(s) also need to be fixed in order to match the emulated ones that we are going to provide.
Quoted 5 lines
* DSDT: certain devices reported in the DSDT may not be available to the guest, but since the DSDT is a run-time generated table we cannot fix it. In order to cope with this, a STAO table will be provided that should be able to signal which devices are not available to the hardware domain. This is in line with the Xen/ACPI implementation for ARM.
Quoted 7 lines
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
Quoted 10 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 16:06, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
Quoted 7 lines
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
We want two things at once here, which afaict can't possibly work:
On one hand we want Dom0 to only see ACPI objects corresponding to its own vCPU-s. Otoh we need Dom0 to see all objects, in order to propagate respective information to Xen.
Jan
Quoted 15 lines · Jan Beulich
Quoted 15 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 16:06, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Quoted 7 lines
Quoted 2 lines
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
We want two things at once here, which afaict can't possibly work:
On one hand we want Dom0 to only see ACPI objects corresponding to its own vCPU-s. Otoh we need Dom0 to see all objects, in order to propagate respective information to Xen.
Could dom0 query Xen for the machine ACPI tables via a hypercall?
David
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 17:17, <[email protected]> wrote:
Quoted 18 lines · Jan Beulich
Quoted 17 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 16:06, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
Quoted 6 lines
Quoted 4 lines
We want two things at once here, which afaict can't possibly work:
On one hand we want Dom0 to only see ACPI objects corresponding to its own vCPU-s. Otoh we need Dom0 to see all objects, in order to propagate respective information to Xen.Could dom0 query Xen for the machine ACPI tables via a hypercall?
That would certainly be doable, but what would it do then with these tables? Loading them just like other tables is not an option, as that would result in a mess of name space collisions. And I don't think abstracting ACPI CA to be able to deal with two independent sets of tables would be very welcome on the Linux or ACPI side...
Jan
Quoted 15 lines · Jan Beulich
Quoted 15 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 16:06, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Quoted 7 lines
Quoted 2 lines
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
We want two things at once here, which afaict can't possibly work:
On one hand we want Dom0 to only see ACPI objects corresponding to its own vCPU-s. Otoh we need Dom0 to see all objects, in order to propagate respective information to Xen.
Having Dom0 see only objects corresponding to its own vCPU-s would of course be nicer from an architectural point of view. What exactly do we need to propagate from Dom0 to Xen? Can we get rid of those calls?
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 17:26, <[email protected]> wrote:
Quoted 18 lines · Jan Beulich
Quoted 17 lines
Quoted 1 line
Quoted 1 line · On 09.02.16 at 16:06, <[email protected]> wrote:
Quoted 7 lines · Jan Beulich
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
It is possible to use the STAO to hide entire objects, including processors, from the DSDT, which should be good enough to prevent dom0 from calling any of the processor related methods you are referreing to. Then we can let Xen do cpuidle and cpufreq as it is already doing.
Would that work? Or do we still need Dom0 to call any ACPI methods for power management?
Quoted 8 lines
Quoted 4 lines
We want two things at once here, which afaict can't possibly work:
On one hand we want Dom0 to only see ACPI objects corresponding to its own vCPU-s. Otoh we need Dom0 to see all objects, in order to propagate respective information to Xen.Having Dom0 see only objects corresponding to its own vCPU-s would of course be nicer from an architectural point of view. What exactly do we need to propagate from Dom0 to Xen? Can we get rid of those calls?
Not really, no. Or else - as said above - there wouldn't be any P- or C-state management anymore.
Jan
El 9/2/16 a les 14:24, Jan Beulich ha escrit:
Quoted 9 lines
Quoted 2 lines
Quoted 1 line
Quoted 1 line · On 08.02.16 at 20:03, <[email protected]> wrote:
*
eflags: all user settable bits are clear.The word "user" here can be mistaken. Perhaps better "all modifiable bits"?
Quoted 2 lines
All other processor registers and flag bits are unspecified. The OS is in charge of setting up it's own stack, GDT and IDT.
Quoted 6 lines
The "flag bits" part should now probably be dropped?
Quoted 2 lines
The format of the boot start info structure is the following (pointed to be %ebx):
"... by %ebx"
Done to both of the above comments.
Quoted 18 lines
Quoted 16 lines
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578 | | ("xEn3" with the 0x80 bit of the "E" set). 4 +----------------+ | flags | SIF_xxx flags. 8 +----------------+ | cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 12 +----------------+ | nr_modules | Number of modules passed to the kernel. 16 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).Quoted 1 line
20 +----------------+
Quoted 4 lines
There having been talk about extending the structure, I think we need some indicator that the consumer can use to know which fields are present. I.e. either a version field, another flags one, or a size one.
Either a version or flags field sounds good to me. A version is probably more desirable in order to prevent confusion with the already present flags field:
0 +----------------+
| magic | Contains the magic value 0x336ec578
| | ("xEn3" with the 0x80 bit of the "E" set).
4 +----------------+
| version | Version of this structure. Current version is 0.
| | New versions are guaranteed to bebackwards-compatible.
8 +----------------+
| flags | SIF_xxx flags.
12 +----------------+
| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 16 +----------------+ | nr_modules | Number of modules passed to the kernel. 20 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).
24 +----------------+
Quoted 14 lines
Quoted 8 lines
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+Quoted 5 lines
| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.12 +----------------+
| reserved |
16 +----------------+
Quoted 3 lines
I've been thinking about this on draft A already: Do we really want to paint ourselves into the corner of not supporting >4Gb modules, by limiting their addresses and sizes to 32 bits?
Hm, that's an itchy question. TBH I doubt we are going to see modules
Quoted 1 line
4GB ATM, but maybe in the future this no longer holds.
I wouldn't mind making all the fields in the module structure 64bits, but I think we should then spell out that Xen will always try to place the modules below the 4GiB boundary when possible.
Quoted 11 lines
Quoted 11 lines
Hardware description
--------------------Hardware description can come from two different sources, just like on (PV)HVM
guests.Description of PV devices will always come from xenbus, and in fact xenbus is the only hardware description that is guaranteed to always be provided to HVMlite guests.
Quoted 5 lines
Quoted 2 lines
Description of physical hardware devices will always come from ACPI, in the absence of any physical hardware device no ACPI tables will be provided.
This seems too strict: How about "in the absence of any physical hardware device ACPI tables may not be provided"?
Right, this should allow us for more freedom when deciding whether to provide ACPI tables or not.
The only case were we might avoid ACPI tables is when no local APIC or IO APIC is provided, and even in this scenario I would be tempted to provide at least a FADT in order to announce that no CMOS RTC is available (and possibly also signal reduced HW).
Quoted 10 lines
Quoted 10 lines
Non-PV devices exposed to the guest
-----------------------------------The initial idea was to simply don't provide any emulated devices to a HVMlite
guest as the default option. We have however identified certain situations where emulated devices could be interesting, both from a performance and ease of implementation point of view. The following list tries to encompass the different identified scenarios:
Quoted 7 lines
Quoted 5 lines
* 1. HVMlite with no emulated devices at all
------------------------------------------
This is the current implementation inside of Xen, everything is disabled by default and the guest has access to the PV devices only. This is of course the most secure design because it has the smaller surface of attack.smallest?
Right, fixed.
Quoted 12 lines
Quoted 11 lines
* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.
Quoted 3 lines
Are you reasonably convinced that the absence of an IO-APIC won't, with LAPICs present, cause more confusion than aid to the OSes wanting to adopt PVHv2?
As long as the data provided in the MADT represent the container provided I think we should be fine. In the case of no IO APICs no entries of type 1 (IO APIC) will be provided in the MADT.
Quoted 9 lines
Quoted 9 lines
* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.
Quoted 6 lines
Quoted 3 lines
Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
Do you really mean "*always*"? What about a system without IO-APIC? Would you mean to emulate one there for no reason?
Oh, a real system without an IO APIC. No, then we wouldn't provide one to the hardware domain, since it makes no sense.
Quoted 2 lines
Also I think you should say "the usage of many PHYSDEV operations", because - as we've already pointed out - some are unavoidable.
Yes, that's right.
Quoted 20 lines
Quoted 20 lines
ACPI
----ACPI tables will be provided to the hardware domain or to unprivileged domains. In the case of unprivileged guests ACPI tables are going to be created by the toolstack and will only contain the set of devices available to the guest, which will at least be the following: local APIC and optionally an IO APIC and passed-through device(s). In order to provide this information from ACPI the following tables are needed as a minimum: RSDT, FADT, MADT and DSDT. If an administrator decides to not provide a local APIC, the MADT table is not going to be provided to the guest OS.
The
ACPI_FADT_NO_CMOS_RTCflag in the FADTboot_flagsfield is going to be used to signal guests that there's no RTC device (the Xen PV wall clock should be used instead). It is likely that this flag is not going to be set for the hardware domain, since it should have access to the RTC present in the host (if there's one). TheACPI_FADT_NO_VGAis also very likely to be set in the sameboot_flagsFADT field for DomUs in order to signal that there's no VGA adapter present.
Quoted 7 lines
Quoted 4 lines
Finally the
ACPI_FADT_HW_REDUCEDis going to be set in the FADT flags field in order to signal that there are no legacy devices: i8259 PIC or i8254 PIT. There's no intention to enable these devices, so it is expected that the hardware-reduced FADT flag is always going to be set.We'll need to be absolutely certain that use of this flag doesn't carry any further implications.
No, after taking a closer look at the ACPI spec I don't think we can use this flag. It has some connotations that wouldn't be true, for example:
- UEFI must be used for boot.
- Sleep state entering is different. Using SLEEP_CONTROL_REG andSLEEP_STATUS_REG instead of SLP_TYP, SLP_EN and WAK_STS. This of course is not something that we can decide for Dom0.
And there are more implications which I think would not hold in our case.
So are we just going to say that HVMlite systems will never have a i8259 PIC or i8254 PIT? Because I don't see a proper way to report this using standard ACPI fields.
Quoted 19 lines
Quoted 13 lines
In the case of the hardware domain, Xen has traditionally passed-through the native ACPI tables to the guest. This is something that of course we still want to do, but in the case of HVMlite Xen will have to make sure that the data passed in the ACPI tables to the hardware domain contain the accurate
hardware description. This means that at least certain tables will have to be modified/mangled before being presented to the guest:* MADT: the number of local APIC entries need to be fixed to match the number of vCPUs available to the guest. The address of the IO APIC(s) also need to be fixed in order to match the emulated ones that we are going to provide.
Quoted 5 lines
* DSDT: certain devices reported in the DSDT may not be available to the guest, but since the DSDT is a run-time generated table we cannot fix it. In order to cope with this, a STAO table will be provided that should be able to signal which devices are not available to the hardware domain. This is in line with the Xen/ACPI implementation for ARM.
Quoted 7 lines
Will STAO be sufficient for everything that may need customization? I'm particularly worried about processor related methods in DSDT or SSDT, which - if we're really meaning to do as you say - would need to be limited (or extended) to the number of vCPU-s Dom0 gets. What's even less clear to me is how you mean to deal with P-, C-, and (once supported) T-state management for CPUs which don't have a vCPU equivalent in Dom0.
I was mostly planning to use the STAO in order to hide the UART. Hiding the CPU methods is also something that we might do from the STAO, but as you say we still need to report them to Xen in order to have proper PM. This is already listed in the section called 'hacks' below.
IMHO, I think the processor related methods should not be hidden and instead a custom Xen driver should be implemented in Dom0 in order to report them to Xen. AFAICT masking them in the STAO would effectively prevent _any_ driver in Dom0 from using them. This is ugly, but I don't see any alternative at all.
Quoted 5 lines
Quoted 5 lines
NB: there are corner cases that I'm not sure how to solve properly. Currently the hardware domain has some 'hacks' regarding ACPI and Xen. At least I'm aware of the following:
Quoted 8 lines
Quoted 6 lines
* 1. Reporting CPU PM info back to Xen: this comes from the DSDT table, and since this table is only available to the hardware domain it has to report the PM info back to Xen so that Xen can perform proper PM.
* 2. Doing proper shutdown (S5) requires the usage of a hypercall, which is mixed with native ACPICA code in most OSes. This is awkward and requires the usage of hooks into ACPICA which we have not yet managed to upstream.Iirc shutdown doesn't require any custom patches anymore in Linux.
Hm, not in Linux, but the hooks have not been merged into ACPICA, which is the standard code base used by many OSes in order to deal with ACPI.
Quoted 10 lines
Quoted 7 lines
* 3. Reporting the PCI devices it finds to the hypervisor: this is not very intrusive in general, so I'm not that pushed to remove it. It's generally easy in any OS to add some kind of hook that's executed every time a PCI device is discovered.
* 4. Report PCI memory-mapped configuration areas to Xen: my opinion regarding this one is the same as (3), it's not really intrusive so I'm not very pushed to remove it.As said in another reply - for both of these, we just can't remove the reporting to Xen.
Right, as I said above I'm not specially pushed to remove them. IMHO they are not that intrusive.
Quoted 14 lines
Quoted 14 lines
MMIO mapping
------------For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
For the hardware domain initial direct MMIO mappings will be set for the following regions:
NOTE: ranges are defined using memory addresses, not pages.
Quoted 8 lines
Quoted 5 lines
* [
0x0,0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.* [
0xF00000,0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.When have you last seen a machine with a hole right below the 16Mb boundary?
Right, I will remove this. Even my old Nehalems (which is the first architecture with IOMMU from Intel IIRC) don't have them.
Should I also mention RMRR?
* Any RMRR regions reported will also be mapped 1:1 to Dom0.
Quoted 13 lines
Quoted 4 lines
* ACPI memory areas: regions with type
E820_ACPIorE820_NVSwill be mapped 1:1 to the guest physical memory map. There are going to be exceptions if Xen has to modify the tables before presenting them to the guest.Quoted 8 lines
* PCI Express MMCFG: if Xen is able to identify any of these regions at boot time they will also be made available to the guest at the same position in it's physical memory map. It is possible that Xen will trap accesses to those regions, but a guest should be able to use the native configuration mechanism in order to interact with this configuration space. If the hardware domain reports the presence of any of those regions using the
PHYSDEVOP_pci_mmcfg_reservedhypercall Xen will also all guest access to them.
Quoted 1 line
s/all guest/allow Dom0/ in this last sentence?
Yes.
Quoted 8 lines
Quoted 7 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction. In order to have the BARs of PCI devices properly mapped the hardware domain needs to call the
PHYSDEVOP_pci_device_addhypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.
Quoted 8 lines
I'm not sure this can work, as it imposes restrictions on the ordering of operations internal of the Dom0 OS: Successfully having probed for a PCI device (and hence reporting its presence to Xen) doesn't imply its BARs have already got set up. Together with the possibility of the OS re-assigning BARs I think we will actually need another hypercall, or the same device-add hypercall may need to be issued more than once per device (i.e. also every time any BAR assignment got changed).
We already trap accesses to 0xcf8/0xcfc, can't we detect BAR reassignments and then act accordingly and change the MMIO mapping?
I was thinking that we could do the initial map at the current position when issuing the hypercall, and then detect further changes and perform remapping if needed, but maybe I'm missing something again that makes this approach not feasible.
Roger.
Quoted 20 lines
Quoted 1 line
Quoted 1 line · On 10.02.16 at 13:01, <[email protected]> wrote:
El 9/2/16 a les 14:24, Jan Beulich ha escrit:
Quoted 14 lines
Quoted 8 lines
Quoted 1 line
Quoted 1 line · On 08.02.16 at 20:03, <[email protected]> wrote:
The layout of each entry in the module structure is the following:
0 +----------------+
| paddr | Physical address of the module.
4 +----------------+
| size | Size of the module in bytes.
8 +----------------+Quoted 5 lines
| cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string.12 +----------------+
| reserved |
16 +----------------+Quoted 3 lines
I've been thinking about this on draft A already: Do we really want to paint ourselves into the corner of not supporting >4Gb modules, by limiting their addresses and sizes to 32 bits?
Quoted 6 lines
Hm, that's an itchy question. TBH I doubt we are going to see modules
Quoted 1 line
4GB ATM, but maybe in the future this no longer holds.
I wouldn't mind making all the fields in the module structure 64bits, but I think we should then spell out that Xen will always try to place the modules below the 4GiB boundary when possible.
Sounds reasonable.
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.
Quoted 7 lines
Quoted 3 lines
Are you reasonably convinced that the absence of an IO-APIC won't, with LAPICs present, cause more confusion than aid to the OSes wanting to adopt PVHv2?
As long as the data provided in the MADT represent the container provided I think we should be fine. In the case of no IO APICs no entries of type 1 (IO APIC) will be provided in the MADT.
I understand that, but are certain OSes are prepared for that?
Quoted 13 lines
Quoted 13 lines
Quoted 12 lines
* 3. HVMlite hardware domain
--------------------------
The aim is that a HVMlite hardware domain is going to work exactly like a HVMlite domain with passed-through devices. This means that the domain will need access to the same set of emulated devices, and that some ACPI tables must be fixed in order to reflect the reality of the container the hardware domain is running on. The ACPI section contains more detailed information about which/how these tables are going to be fixed.Note that in this scenario the hardware domain will *always* have a local APIC and IO APIC, and that the usage of PHYSDEV operations and PIRQ event channels is going to be removed in favour of the bare metal mechanisms.
Quoted 5 lines
Quoted 2 lines
Do you really mean "*always*"? What about a system without IO-APIC? Would you mean to emulate one there for no reason?
Oh, a real system without an IO APIC. No, then we wouldn't provide one to the hardware domain, since it makes no sense.
I.e. the above should say "... will always local APICs and IO-APICs mirroring the physical machine's, ..." or something equivalent.
Quoted 36 lines
Quoted 20 lines
Quoted 20 lines
ACPI
----ACPI tables will be provided to the hardware domain or to unprivileged domains. In the case of unprivileged guests ACPI tables are going to be created by the toolstack and will only contain the set of devices available to the guest, which will at least be the following: local APIC and optionally an IO APIC and passed-through device(s). In order to provide this information from ACPI the following tables are needed as a minimum: RSDT, FADT, MADT and DSDT. If an administrator decides to not provide a local APIC, the MADT table is not going to be provided to the guest OS.
The
ACPI_FADT_NO_CMOS_RTCflag in the FADTboot_flagsfield is going to be used to signal guests that there's no RTC device (the Xen PV wall clock should be used instead). It is likely that this flag is not going to be set for the hardware domain, since it should have access to the RTC present in the host (if there's one). TheACPI_FADT_NO_VGAis also very likely to be set in the sameboot_flagsFADT field for DomUs in order to signal that there's no VGA adapter present.Quoted 7 lines
Quoted 4 lines
Finally the
ACPI_FADT_HW_REDUCEDis going to be set in the FADT flags field in order to signal that there are no legacy devices: i8259 PIC or i8254 PIT. There's no intention to enable these devices, so it is expected that the hardware-reduced FADT flag is always going to be set.We'll need to be absolutely certain that use of this flag doesn't carry any further implications.
No, after taking a closer look at the ACPI spec I don't think we can use this flag. It has some connotations that wouldn't be true, for example:
- UEFI must be used for boot.
- Sleep state entering is different. UsingSLEEP_CONTROL_REGandSLEEP_STATUS_REGinstead ofSLP_TYP,SLP_ENandWAK_STS. This of course is not something that we can decide for Dom0.
Quoted 5 lines
And there are more implications which I think would not hold in our case.
So are we just going to say that HVMlite systems will never have a i8259 PIC or i8254 PIT? Because I don't see a proper way to report this using standard ACPI fields.
I think so, yes.
Quoted 23 lines
Quoted 14 lines
Quoted 14 lines
MMIO mapping
------------For DomUs without any device passed-through no direct MMIO mappings will be present in the physical memory map presented to the guest. For DomUs with devices passed-though the toolstack will create direct MMIO mappings as part of the domain build process, and thus no action will be required from the DomU.
For the hardware domain initial direct MMIO mappings will be set for the following regions:
NOTE: ranges are defined using memory addresses, not pages.
Quoted 8 lines
Quoted 5 lines
* [
0x0,0xFFFFF]: the low 1MiB will be mapped into the physical guest memory map at the same position.* [
0xF00000,0xFFFFFF]: the ISA memory hole will be mapped 1:1 into the guest physical memory.When have you last seen a machine with a hole right below the 16Mb boundary?
Quoted 6 lines
Right, I will remove this. Even my old Nehalems (which is the first architecture with IOMMU from Intel IIRC) don't have them.
Should I also mention RMRR?
* Any RMRR regions reported will also be mapped 1:1 to Dom0.
That's a good ideas, yes. But please make explicit that such mappings will go away together with the removal of devices (for pass-through purposes) from Dom0.
Quoted 17 lines
Quoted 8 lines
Quoted 7 lines
* PCI BARs: it's not possible for Xen to know the position of the BARs of the PCI devices without hardware domain interaction. In order to have the BARs of PCI devices properly mapped the hardware domain needs to call the
PHYSDEVOP_pci_device_addhypercall, that will take care of setting up the BARs in the guest physical memory map using 1:1 MMIO mappings. This procedure will be transparent from guest point of view, and upon returning from the hypercall mappings must be already established.Quoted 8 lines
I'm not sure this can work, as it imposes restrictions on the ordering of operations internal of the Dom0 OS: Successfully having probed for a PCI device (and hence reporting its presence to Xen) doesn't imply its BARs have already got set up. Together with the possibility of the OS re-assigning BARs I think we will actually need another hypercall, or the same device-add hypercall may need to be issued more than once per device (i.e. also every time any BAR assignment got changed).
Quoted 7 lines
We already trap accesses to 0xcf8/0xcfc, can't we detect BAR reassignments and then act accordingly and change the MMIO mapping?
I was thinking that we could do the initial map at the current position when issuing the hypercall, and then detect further changes and perform remapping if needed, but maybe I'm missing something again that makes this approach not feasible.
I think that's certainly possible, but will require quite a bit of care when implementing. (In fact this way I think we could then also observe bus renumbering, without requiring Dom0 to remove and then re-add all affected devices. Konrad - what do you think?)
Jan
El 10/2/16 a les 13:53, Jan Beulich ha escrit:
Quoted 19 lines
Quoted 19 lines
Quoted 1 line
Quoted 1 line · On 10.02.16 at 13:01, <[email protected]> wrote:
El 9/2/16 a les 14:24, Jan Beulich ha escrit:
Quoted 16 lines
Quoted 12 lines
Quoted 1 line
Quoted 1 line · On 08.02.16 at 20:03, <[email protected]> wrote:
* 2. HVMlite with (or capable to) PCI-passthrough
-----------------------------------------------
The current model of PCI-passthrought in PV guests is complex and requires heavy modifications to the guest OS. Going forward we would like to remove this limitation, by providing an interface that's the same as found on bare metal. In order to do this, at least an emulated local APIC should be provided to guests, together with the access to a PCI-Root complex. As said in the 'Hardware description' section above, this will also require ACPI. So this proposed scenario will require the following elements that are not present in the minimal (or default) HVMlite implementation: ACPI, local APIC, IO APIC (optional) and PCI-Root complex.Are you reasonably convinced that the absence of an IO-APIC won't, with LAPICs present, cause more confusion than aid to the OSes wanting to adopt PVHv2?
Quoted 5 lines
Quoted 3 lines
As long as the data provided in the MADT represent the container provided I think we should be fine. In the case of no IO APICs no entries of type 1 (IO APIC) will be provided in the MADT.
I understand that, but are certain OSes are prepared for that?
Well, given that some modifications will always be needed in order to run as a PVH guest, I don't think this should stop us. FWIW, I think FreeBSD should be able to cope with this without much fuss:
https://svnweb.freebsd.org/base/head/sys/x86/acpica/madt.c?revision=291686&view=co
The detection of local APIC and IO APICs is quite isolated from each other, and the failure to find any IO APICs should not prevent local APICs from being enabled. Although I don't think there's any hardware with this setup, such configuration would be valid from an ACPI point of view. I've of course not tested this in any way, so those are only observations by a quick look at the code. I cannot speak about Linux.
Also, thanks for the observations and comments on the document.
Roger.
Quoted 7 lines · Roger Pau Monné
The detection of local APIC and IO APICs is quite isolated from each other, and the failure to find any IO APICs should not prevent local APICs from being enabled. Although I don't think there's any hardware with this setup, such configuration would be valid from an ACPI point of view. I've of course not tested this in any way, so those are only observations by a quick look at the code. I cannot speak about Linux.
I believe Linux should be able to handle this as well:
https://git.kernel.org/cgit/linux/kernel/git/torvalds/linux.git/tree/arch/x86/kernel/acpi/boot.c?id=refs/tags/v4.5-rc3#n1140
I also removed ioapic entries from hvmloader's ACPI builder and the (HVM) guest came up with no immediately visible issues.
-boris
Quoted 19 lines · Roger Pau Monné
The format of the boot start info structure is the following (pointed to be %ebx):
NOTE: nothing will be loaded at physical address 0, so a 0 value in any of the address fields should be treated as not present.
0 +----------------+
| magic | Contains the magic value 0x336ec578 | | ("xEn3" with the 0x80 bit of the "E" set). 4 +----------------+ | flags | SIF_xxx flags. 8 +----------------+ | cmdline_paddr | Physical address of the command line, | | a zero-terminated ASCII string. 12 +----------------+ | nr_modules | Number of modules passed to the kernel. 16 +----------------+ | modlist_paddr | Physical address of an array of modules | | (layout of the structure below).
Quoted 1 line
20 +----------------+
Do we want to add version field here?
-boris
_______________________________________________
Xen-devel mailing list
[email protected]
http://lists.xen.org/xen-devel