libata-scsi: fix D_SENSE bit relection in control mode page
PATCH v2 1/2 libata-scsi: fix D_SENSE bit relection in control mode page
From: Tom Yan <[email protected]>
The bit should always be set to 1 when the requested version of page is "changeable" because we've made it so in ata_mselect_control(). Also, it should always be set to 1 if ATA_DFLAG_D_SENSE is set (when the requested version of page is "current" or "default").
Signed-off-by Tom Yan <[email protected]>
drivers/ata/libata-scsi.c +1 -1
@@ -2446,7 +2446,7 @@ static unsigned int ata_msense_ctl_mode(struct ata_device *dev, u8 *buf, bool changeable) {modecpy (buf, def_control_mpage,sizeof (def_control_mpage), changeable); -if (changeable && (dev->flags &ATA_DFLAG_D_SENSE )) +if (changeable || (dev->flags &ATA_DFLAG_D_SENSE )) buf[2 ] |= (1 <<2 );/* Descriptor sense requested */ return sizeof (def_control_mpage); }
Signature · 1 line