Linux raid wiki - force assembling an array where one drive has a different event count - advice needed

DISCUSSION Wols Lists 3 participants 3 messages Sep 23, 2016 – Sep 24, 2016 MD RAID

lore
Share & tools
lore

Wols Lists

author
#0 lore raw

As I understand it, the event count on all devices in an array should be the same. If they're a little bit different it doesn't matter too much. My question is how much does it matter?

Let's say I've got a raid-5 and suddenly realise that one of the drives has failed and been kicked from the array. What happens if I force a reassemble? Or do a --re-add?

I don't actually have a clue, and if I'm updating the wiki I need to know. What I would HOPE happens, is that the raid code fires off an integrity scan, reading each stripe, and updating the re-added drive if it's out-of-date. Is this what the bitmap enables? So the raid code can work out what changes have been made since the drive has been booted?

Or does forced re-adding risk damaging the data because the raid code can't tell what is out-of-date and what is current on the re-added drive?

Basically, what I'm trying to get at, is that if there's one disk missing in a raid5, is a user better off just adding a new drive and rebuilding the array (risking a failure in another drive), or are they better off trying to add the failed drive back in, and then doing a --replace.

And I guess the same logic applies with raid6.

Cheers,
Wol

#1 lore raw
Quoted 8 lines · Wols Lists

As I understand it, the event count on all devices in an array should be the same. If they're a little bit different it doesn't matter too much. My question is how much does it matter?

Let's say I've got a raid-5 and suddenly realise that one of the drives has failed and been kicked from the array. What happens if I force a reassemble? Or do a --re-add?

Quoted 5 lines

I don't actually have a clue, and if I'm updating the wiki I need to know. What I would HOPE happens, is that the raid code fires off an integrity scan, reading each stripe, and updating the re-added drive if it's out-of-date. Is this what the bitmap enables? So the raid code can work out what changes have been made since the drive has been booted?

If you have a bitmap, and you re-add a drive to the array, then it will check the bitmap to find out what is out of date, and then re-sync those parts of the drive. If there is no bitmap, and you re-add a drive, then the entire drive will be re-written/synced.

Quoted 2 lines

Or does forced re-adding risk damaging the data because the raid code can't tell what is out-of-date and what is current on the re-added drive?

There is no need to "force" re-adding a drive if there is still all the data in the array. The only reason you would force an array to assemble is in the case one drive has failed (totally dead/unusable, or failed a long time ago) and a second drive has failed with only a few bad sectors, or a timeout mismatch. Then you forget the oldest drive, force assemble with the good drives plus the recently failed drive, and then recover as much data as possible. The other useful scenario is a small number of bad sectors on two drives, but not in the same location. You won't survive a full re-sync on either drive, but forcing assembly might allow you to read all the data.

Quoted 5 lines

Basically, what I'm trying to get at, is that if there's one disk missing in a raid5, is a user better off just adding a new drive and rebuilding the array (risking a failure in another drive), or are they better off trying to add the failed drive back in, and then doing a --replace.

It will depend on why the drive failed in the first place. If it failed due to a timeout mismatch, or user error (pulled the drive by accident, etc and you have a bitmap enabled, then re-adding is the best option (because you will only re-sync a small portion of the drive. If you do not have a bitmap, and you suspect one or more of your drives are having problems / likely to have read failures during the re-sync (this is usually when people come to the list/wiki) then it could be helpful to force the assemble (ie, ignore the event count). This will allow you to get your data off the array, or at least get to a point of full redundancy, you could then either add a drive to move to RAID6, or replace each drive (one by one) to get rid of the unreliable drives.

Quoted 1 line

And I guess the same logic applies with raid6.

Again, usually you would only do this if you lost 3 drives on the RAID6, 2 on RAID5.... Otherwise, you should re-build the drive in full (or suffer random data corruption). The bitmap is only useful after you temporarily lose one or more drives <= to the number of redundant drives (ie, this applies to RAID1 and RAID10 as well).

So, IMHO, in the general scenario, you should not force assemble if you want to be sure you recover all your data. It is something that is done to reduce data loss from 100% to some unknown value depending on the event count difference, but usually it is very small.

Generally, you should do a verify/repair on the array afterwards (even if the data is lost, at least they will be consistent about what it returns), and a fsck.

Don't consider the above as gospel, but it matches the various scenarios I've seen on this list....

Regards,
Adam

#2 lore raw
Quoted 61 lines · Adam Goryachev
Quoted 8 lines · Wols Lists

As I understand it, the event count on all devices in an array should be the same. If they're a little bit different it doesn't matter too much. My question is how much does it matter?

Let's say I've got a raid-5 and suddenly realise that one of the drives has failed and been kicked from the array. What happens if I force a reassemble? Or do a --re-add?

Quoted 5 lines

I don't actually have a clue, and if I'm updating the wiki I need to know. What I would HOPE happens, is that the raid code fires off an integrity scan, reading each stripe, and updating the re-added drive if it's out-of-date. Is this what the bitmap enables? So the raid code can work out what changes have been made since the drive has been booted?

If you have a bitmap, and you re-add a drive to the array, then it will check the bitmap to find out what is out of date, and then re-sync those parts of the drive.
If there is no bitmap, and you re-add a drive, then the entire drive will be re-written/synced.

Quoted 2 lines

Or does forced re-adding risk damaging the data because the raid code can't tell what is out-of-date and what is current on the re-added drive?

There is no need to "force" re-adding a drive if there is still all the data in the array. The only reason you would force an array to assemble is in the case one drive has failed (totally dead/unusable, or failed a long time ago) and a second drive has failed with only a few bad sectors, or a timeout mismatch. Then you forget the oldest drive, force assemble with the good drives plus the recently failed drive, and then recover as much data as possible.
The other useful scenario is a small number of bad sectors on two drives, but not in the same location. You won't survive a full re-sync on either drive, but forcing assembly might allow you to read all the data.

Quoted 5 lines

Basically, what I'm trying to get at, is that if there's one disk missing in a raid5, is a user better off just adding a new drive and rebuilding the array (risking a failure in another drive), or are they better off trying to add the failed drive back in, and then doing a --replace.

It will depend on why the drive failed in the first place. If it failed due to a timeout mismatch, or user error (pulled the drive by accident, etc and you have a bitmap enabled, then re-adding is the best option (because you will only re-sync a small portion of the drive. If you do not have a bitmap, and you suspect one or more of your drives are having problems / likely to have read failures during the re-sync (this is usually when people come to the list/wiki) then it could be helpful to force the assemble (ie, ignore the event count). This will allow you to get your data off the array, or at least get to a point of full redundancy, you could then either add a drive to move to RAID6, or replace each drive (one by one) to get rid of the unreliable drives.

Quoted 1 line

And I guess the same logic applies with raid6.

Again, usually you would only do this if you lost 3 drives on the RAID6, 2 on RAID5.... Otherwise, you should re-build the drive in full (or suffer random data corruption). The bitmap is only useful after you temporarily lose one or more drives <= to the number of redundant drives (ie, this applies to RAID1 and RAID10 as well).

So, IMHO, in the general scenario, you should not force assemble if you want to be sure you recover all your data. It is something that is done to reduce data loss from 100% to some unknown value depending on the event count difference, but usually it is very small.

Quoted 6 lines

Generally, you should do a verify/repair on the array afterwards (even if the data is lost, at least they will be consistent about what it returns), and a fsck.

Don't consider the above as gospel, but it matches the various scenarios I've seen on this list....

This is a very good summary. Especially the bit about forced assembly being the point most people are at when they come to this list.