libata - PIO error handling fix
PATCH 2/3 libata - PIO error handling fix
Hi, Jeff:
Tested burning CD-RW with libata-dev-2.6 and cdrecord:
1. ATAPI DMA mode - tested OK
2. ATAPI PIO mode - test failed when cdrecord finishes burning and issues MODE_SELECT to the device.
After checking the log, it showed that MODE_SELECT caused ata_pio_complete() to return error.
However, the error is not handled by ata_pio_task().
Attached please find the patch for ata_pio_task() error handling for your review. (The patch is against the libata-dev-2.6 tree. )
Changes in the patch:
1. End the PIO task when PIO_ST_IDLE state is entered
2. End the PIO task after PIO_ST_TMOUT and PIO_ST_ERR state handled by ata_pio_error()
3. Remove the first "if" statement to handle the error condition returned from ata_pio_block(), ata_pio_complete() and ata_pio_poll().
Change #2 is not so necessary since ata_pio_error() will put the cmd to PIO_ST_IDLE state
after the error condition is handled. The change just saves a function call to queue_work().
Tested OK on on my machine with pdc20275 and ASUS CD-RW drive.
Albert
---
drivers/scsi/libata-core.c 2004-12-02 18:57:48.719220063 +0800 renamed from drivers/scsi/libata-core.c 2004-11-30 12:52:28.000000000 +0800 +9 -10
@@ -2399,6 +2399,9 @@ unsigned long timeout = 0; switch (ap->pio_task_state) { + case PIO_ST_IDLE: + return; + case PIO_ST: ata_pio_block(ap); break;
@@ -2415,18 +2418,14 @@ case PIO_ST_TMOUT: case PIO_ST_ERR: ata_pio_error(ap); - break; + return; } - if ((ap->pio_task_state != PIO_ST_IDLE) && - (ap->pio_task_state != PIO_ST_TMOUT) && - (ap->pio_task_state != PIO_ST_ERR)) { - if (timeout) - queue_delayed_work(ata_wq, &ap->pio_task, - timeout); - else - queue_work(ata_wq, &ap->pio_task); - } + if (timeout) + queue_delayed_work(ata_wq, &ap->pio_task, + timeout); + else + queue_work(ata_wq, &ap->pio_task); } static void atapi_request_sense(struct ata_port *ap, struct ata_device *dev,
drivers/scsi/libata-core.c +9 -10
@@ -2399,6 +2399,9 @@unsigned long timeout =0 ;switch (ap->pio_task_state) { +case PIO_ST_IDLE : +return ; +case PIO_ST :ata_pio_block (ap);break ;
@@ -2415,18 +2418,14 @@case PIO_ST_TMOUT :case PIO_ST_ERR :ata_pio_error (ap); -break ; +return ; } -if ((ap->pio_task_state !=PIO_ST_IDLE ) && - (ap->pio_task_state !=PIO_ST_TMOUT ) && - (ap->pio_task_state !=PIO_ST_ERR )) { -if (timeout) -queue_delayed_work (ata_wq, &ap->pio_task, - timeout); -else -queue_work (ata_wq, &ap->pio_task); - } +if (timeout) +queue_delayed_work (ata_wq, &ap->pio_task, + timeout); +else +queue_work (ata_wq, &ap->pio_task); } static void atapi_request_sense(struct ata_port *ap, struct ata_device *dev,
Quoted 9 lines · Albert Lee
Hi, Jeff:
Tested burning CD-RW with libata-dev-2.6 and cdrecord:
1. ATAPI DMA mode - tested OK
2. ATAPI PIO mode - test failed when cdrecord finishes burning and issuesMODE_SELECTto the device.After checking the log, it showed that
MODE_SELECTcausedata_pio_complete()to return error.
However, the error is not handled byata_pio_task().
Quoted 8 lines
Attached please find the patch for
ata_pio_task()error handling for your review. (The patch is against the libata-dev-2.6 tree. )Changes in the patch:
1. End the PIO task whenPIO_ST_IDLEstate is entered
2. End the PIO task afterPIO_ST_TMOUTandPIO_ST_ERRstate handled byata_pio_error()
3. Remove the first "if" statement to handle the error condition returned fromata_pio_block(),ata_pio_complete()andata_pio_poll().
Jeff, 3. is the same issue + fix that was reported earlier by Tim. It seems that we have both somehow forgot about it. :-|
Quoted 4 lines
Change #2 is not so necessary since
ata_pio_error()will put the cmd toPIO_ST_IDLEstate
after the error condition is handled. The change just saves a function call toqueue_work().Tested OK on on my machine with pdc20275 and ASUS CD-RW drive.
Patch looks fine for me.
Bartlomiej