S390x: CPU Topology Information

PATCH Superseded Pierre Morel 4 participants 13 messages May 19, 2023 – Jun 2, 2023

Subsystems (2)

v9 of 21 Superseded Latest is v21 →

lore
Share & tools
lore
#0 lore raw

v9 cover S390x: CPU Topology Information

Hi,

new version of the kvm-unit-test s390x CPU topology series.

0. what is new in this new spin
-------------------------------

- more configuration tested in unittests.cfg
- one of the tested configuration using 248 processors will failed until SCLP bug is corrected
- several cleanup

1. what is done
---------------

- First part is checking PTF errors, for KVM and LPAR

- Second part is checking PTF polarization change and STSI with the cpu topology including drawers and books. This tests are run for KVM only.

To run these tests under KVM successfully you need Linux 6.0 and the latest QEMU patches you find at:

https://lists.gnu.org/archive/html/qemu-devel/2023-04/msg04568.html

Note that Fedora-35 already has the CPU Topology backport for Linux.

To start the test in KVM just do:

# ./run_tests.sh topology

or something like:

# ./s390x-run s390x/topology.elf \
	-smp 5,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 \
	-append '-drawers 3 -books 3 -sockets 4 -cores 4'

Of course the declaration of the number of drawers, books, socket and core must be coherent between -smp and -append arguments.

- Running the test on LPAR has been getestet on a46lp21

Regards,
Pierre

Pierre Morel (2):
s390x: topology: Check the Perform Topology Function
s390x: topology: Checking Configuration Topology Information

 lib/s390x/sclp.c    |   6 +
 lib/s390x/sclp.h    |   4 +-
 lib/s390x/stsi.h    |  36 ++++
 s390x/Makefile      |   1 +
 s390x/topology.c    | 515 ++++++++++++++++++++++++++++++++++++++++++++
 s390x/unittests.cfg |  14 ++
 6 files changed, 575 insertions(+), 1 deletion(-)
 create mode 100644 s390x/topology.c
Signature · 52 lines
2.31.1

new in v8:

- use report_fail instead of report(0,...
  (Nico)

- add 2 more configurations in unittests.cfg
  (Nico)

new in v8:

- define PTF_INVALID_FUNCTION
  (Claudio)

- test every single bits for specification in the ptf instruction
  (Claudio)

- test vertical polarization twice
  (Claudio)

- add an assert(read_info)
  (Nico)

- changed skips
  (Nico)


new in v7:

- better checks using device attributes on commandline
  (Pierre)
- use builtin to get the number of CPU in the TLE mask
  (Thomas)
- use Elvis (not dead)
  (Thomas)
- reset before tests
  (Nina)
- splitting test_ptf in small functions
  (Thomas)
- check every ptf function code for program check
  (Nina)
- Test made on LPAR
  (Janosch)
- use a single page for SYSIB
  (Thomas)
- abort on wrong parameter
  (Thomas)
- implement SYSIB check with a recursive funtion
  (Nina)
- diverse little changes (naming, clearer checks
  (Nina, Thomas)
#1 lore raw

PATCH v9 1/2 s390x: topology: Check the Perform Topology Function

We check that the PTF instruction is working correctly when the cpu topology facility is available.

For KVM only, we test changing of the polarity between horizontal and vertical and that a reset set the horizontal polarity.

---
 s390x/Makefile      |   1 +
 s390x/topology.c    | 189 ++++++++++++++++++++++++++++++++++++++++++++
 s390x/unittests.cfg |   3 +
 3 files changed, 193 insertions(+)
 create mode 100644 s390x/topology.c
s390x/Makefile +1 -0
index a80db53..fe77b07 100644
@@ -40,6 +40,7 @@ tests += $(TEST_DIR)/panic-loop-pgm.elf
 tests += $(TEST_DIR)/migration-sck.elf
 tests += $(TEST_DIR)/exittime.elf
 tests += $(TEST_DIR)/ex.elf
+tests += $(TEST_DIR)/topology.elf
 
 pv-tests += $(TEST_DIR)/pv-diags.elf
 
s390x/topology.c new file +189 -0

189 lines not on this page · raw message

s390x/unittests.cfg +3 -0
index b61faf0..fc3666b 100644
@@ -218,3 +218,6 @@ extra_params = -append '--parallel'
 
 [execute]
 file = ex.elf
+
+[topology]
+file = topology.elf
Signature · 1 line
2.31.1
Reviewed-by on v9 1/2
#2 lore raw

Re: [kvm-unit-tests PATCH v9 1/2] s390x: topology: Check the Perform Topology Function

Quoting Pierre Morel (2023-05-19 13:22:35)
[...]

Quoted 5 lines
s390x/topology.c new file +0 -0
new file mode 100644
index 0000000..2acede0

[...]

s390x/topology.c line 52

Quoted 6 lines
s390x/topology.c new file +6 -0
+static void check_privilege(int fc)
+{
+       unsigned long rc;
+
+       report_prefix_push("Privilege");
+       report_info("function code %d", fc);

report() messages should be unique.

Can you please make this a
report_prefix_pushf("Privileged fc %d", fc);
and get rid of the report_info()?

With this change:

#3 lore raw

Re: [kvm-unit-tests PATCH v9 1/2] s390x: topology: Check the Perform Topology Function

Quoted 16 lines · Nico Boehr

Quoting Pierre Morel (2023-05-19 13:22:35)
[...]

Quoted 5 lines
s390x/topology.c new file +0 -0
new file mode 100644
index 0000000..2acede0

[...]

s390x/topology.c line 52

Quoted 6 lines
s390x/topology.c new file +6 -0
+static void check_privilege(int fc)
+{
+       unsigned long rc;
+
+       report_prefix_push("Privilege");
+       report_info("function code %d", fc);

report() messages should be unique.

Quoted 7 lines

Can you please make this a
report_prefix_pushf("Privileged fc %d", fc);
and get rid of the report_info()?

With this change:

Yes, thanks

Pierre

#4 lore raw

PATCH v9 2/2 s390x: topology: Checking Configuration Topology Information

In reply to Pierre Morel

STSI with function code 15 is used to store the CPU configuration topology.

We retrieve the maximum nested level with SCLP and use the topology tree provided by the drawers, books, sockets, cores arguments.

We check :
- if the topology stored is coherent between the QEMU -smp parameters and kernel parameters.
- the number of CPUs
- the maximum number of CPUs
- the number of containers of each levels for every STSI(15.1.x) instruction allowed by the machine.

---
 lib/s390x/sclp.c    |   6 +
 lib/s390x/sclp.h    |   4 +-
 lib/s390x/stsi.h    |  36 +++++
 s390x/topology.c    | 326 ++++++++++++++++++++++++++++++++++++++++++++
 s390x/unittests.cfg |  11 ++
 5 files changed, 382 insertions(+), 1 deletion(-)
lib/s390x/sclp.c +6 -0
index 390fde7..acdc8a9 100644
@@ -238,3 +238,9 @@ uint64_t get_max_ram_size(void)
 {
 	return max_ram_size;
 }
+
+uint64_t sclp_get_stsi_mnest(void)
+{
+	assert(read_info);
+	return read_info->stsi_parm;
+}
lib/s390x/sclp.h +3 -1
index 853529b..6a611bc 100644
@@ -150,7 +150,8 @@ typedef struct ReadInfo {
 	SCCBHeader h;
 	uint16_t rnmax;
 	uint8_t rnsize;
-	uint8_t  _reserved1[16 - 11];       /* 11-15 */
+	uint8_t  _reserved1[15 - 11];       /* 11-14 */
+	uint8_t stsi_parm;                  /* 15-15 */
 	uint16_t entries_cpu;               /* 16-17 */
 	uint16_t offset_cpu;                /* 18-19 */
 	uint8_t  _reserved2[24 - 20];       /* 20-23 */
@@ -341,5 +342,6 @@ int sclp_service_call(unsigned int command, void *sccb);
 void sclp_memory_setup(void);
 uint64_t get_ram_size(void);
 uint64_t get_max_ram_size(void);
+uint64_t sclp_get_stsi_mnest(void);
 
 #endif /* _S390X_SCLP_H_ */
lib/s390x/stsi.h +36 -0
index bebc492..1351a6f 100644
@@ -29,4 +29,40 @@ struct sysinfo_3_2_2 {
 	uint8_t ext_names[8][256];
 };
 
+#define CPUS_TLE_RES_BITS 0x00fffffff8000000UL
+struct topology_core {
+	uint8_t nl;
+	uint8_t reserved1[3];
+	uint8_t reserved4:5;
+	uint8_t d:1;
+	uint8_t pp:2;
+	uint8_t type;
+	uint16_t origin;
+	uint64_t mask;
+};
+
+#define CONTAINER_TLE_RES_BITS 0x00ffffffffffff00UL
+struct topology_container {
+	uint8_t nl;
+	uint8_t reserved[6];
+	uint8_t id;
+};
+
+union topology_entry {
+	uint8_t nl;
+	struct topology_core cpu;
+	struct topology_container container;
+};
+
+#define CPU_TOPOLOGY_MAX_LEVEL 6
+struct sysinfo_15_1_x {
+	uint8_t reserved0[2];
+	uint16_t length;
+	uint8_t mag[CPU_TOPOLOGY_MAX_LEVEL];
+	uint8_t reserved0a;
+	uint8_t mnest;
+	uint8_t reserved0c[4];
+	union topology_entry tle[];
+};
+
 #endif  /* _S390X_STSI_H_ */
s390x/topology.c +326 -0

349 lines not on this page · raw message

s390x/unittests.cfg +11 -0
index fc3666b..ee34741 100644
@@ -221,3 +221,14 @@ file = ex.elf
 
 [topology]
 file = topology.elf
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on
+
+[topology-3]
+file = topology.elf
+extra_params = -smp drawers=2,books=2,sockets=31,cores=2,maxcpus=248  -append '-drawers 2 -books 2 -sockets 31 -cores 2'
Signature · 1 line
2.31.1
#5 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

Quoted 17 lines · Pierre Morel

STSI with function code 15 is used to store the CPU configuration topology.

We retrieve the maximum nested level with SCLP and use the topology tree provided by the drawers, books, sockets, cores arguments.

We check :
- if the topology stored is coherent between the QEMU -smp parameters and kernel parameters.
- the number of CPUs
- the maximum number of CPUs
- the number of containers of each levels for every STSI(15.1.x) instruction allowed by the machine.

[topology]
file = topology.elf

s390x/unittests.cfg file = ex.elf · line 230

Quoted 7 lines
s390x/unittests.cfg +7 -0
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

#6 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

Quoted 40 lines · Janosch Frank
Quoted 39 lines · Pierre Morel

STSI with function code 15 is used to store the CPU configuration topology.

We retrieve the maximum nested level with SCLP and use the topology tree provided by the drawers, books, sockets, cores arguments.

We check :
- if the topology stored is coherent between the QEMU -smp parameters and kernel parameters.
- the number of CPUs
- the maximum number of CPUs
- the number of containers of each levels for every STSI(15.1.x) instruction allowed by the machine.

  [topology]
  file = topology.elf
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)

(quoted diff) +2 -0
+# 1 CPU on socket 2
+extra_params = -smp 

1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on
-device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10
-device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'

s390x/unittests.cfg +4 -0
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 

1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low

Quoted 8 lines
Quoted 6 lines

-device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

I think it will, we do not use anything specific to the CPU but the Configuration topology facility which start with z10EC and AFAIU QEMU will accept a processor newer than the one of the host, at least it does on my LPAR (VM z16b > host z16a)

But we can use z13 as basis, which also covers the case where I forgot something.

Quoted 2 lines

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

It will crash, QEMU will refuse the drawers and book parameters if the QEMU patch for topology has not been applied.

So, I should first propose a simple unittests.cfg working with both, which will SKIP with "Topology facility not present" without the patch.

When the patch is becoming used we can add more testings.

Thanks for the comments.

Pierre

#7 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

Quoted 55 lines · Pierre Morel
Quoted 44 lines · Janosch Frank
Quoted 43 lines · Pierre Morel

STSI with function code 15 is used to store the CPU configuration topology.

We retrieve the maximum nested level with SCLP and use the topology tree provided by the drawers, books, sockets, cores arguments.

We check :
- if the topology stored is coherent between the QEMU -smp parameters and kernel parameters.
- the number of CPUs
- the maximum number of CPUs
- the number of containers of each levels for every STSI(15.1.x) instruction allowed by the machine.

  [topology]
  file = topology.elf
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)

(quoted diff) +2 -0
+# 1 CPU on socket 2
+extra_params = -smp

1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'

s390x/unittests.cfg +4 -0
+
+[topology-2]
+file = topology.elf
+extra_params = -smp

1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers
2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device

Quoted 8 lines
Quoted 5 lines

z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

Quoted 7 lines

I think it will, we do not use anything specific to the CPU but the Configuration topology facility which start with z10EC
and AFAIU QEMU will accept a processor newer than the one of the host, at least it does on my LPAR (VM z16b > host z16a)

But we can use z13 as basis, which also covers the case where I forgot something.

I don't really care what we use as a base.
But we should avoid a "FAIL" if the tests are run on a machine that's older than what's specified here.

Quoted 6 lines
Quoted 5 lines

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

Quoted 8 lines

It will crash, QEMU will refuse the drawers and book parameters if the QEMU patch for topology has not been applied.

So, I should first propose a simple unittests.cfg working with both, which will SKIP with "Topology facility not present" without the patch.

When the patch is becoming used we can add more testings.

As stated above, the test shouldn't fail if the QEMU code is missing.
If there's no convenient way to do feature checking for this, then we can put those tests into a special group and make sure that this group is run in the CI once the QEMU code is upstream.

#8 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

In reply to Janosch Frank

Quoting Janosch Frank (2023-06-01 11:38:37)
[...]

Quoted 4 lines
Quoted 4 lines

[topology]
file = topology.elf

s390x/unittests.cfg +2 -0
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
Quoted 8 lines

s390x/unittests.cfg file = ex.elf · line 230

Quoted 5 lines
s390x/unittests.cfg +5 -0
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

It causes a skip, I reproduced this on a z14 by changing to z15:
SKIP topology (qemu-system-s390x: unable to find CPU model 'z15')

If we can make this more generic so the tests run on older machines it would be good, but if we can't it wouldn't break (i.e. FAIL) on older machines.

Quoted 2 lines

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

Just tried on my box, skips with:
SKIP topology (qemu-system-s390x: Parameter 'smp.books' is unexpected)

So I think we're good here.

#9 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

Quoted 21 lines · Nico Boehr

Quoting Janosch Frank (2023-06-01 11:38:37)
[...]

Quoted 4 lines
Quoted 4 lines

[topology]
file = topology.elf

s390x/unittests.cfg +2 -0
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
Quoted 8 lines

s390x/unittests.cfg file = ex.elf · line 230

Quoted 5 lines
s390x/unittests.cfg +5 -0
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

It causes a skip, I reproduced this on a z14 by changing to z15:
SKIP topology (qemu-system-s390x: unable to find CPU model 'z15')

If we can make this more generic so the tests run on older machines it would be good, but if we can't it wouldn't break (i.e. FAIL) on older machines.

Quoted 7 lines
Quoted 2 lines

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

Just tried on my box, skips with:
SKIP topology (qemu-system-s390x: Parameter 'smp.books' is unexpected)

So I think we're good here.

Perfect, thanks for checking!

#10 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

In reply to Nico Boehr
Quoted 15 lines · Nico Boehr

Quoting Janosch Frank (2023-06-01 11:38:37)
[...]

Quoted 4 lines
Quoted 4 lines

[topology]
file = topology.elf

s390x/unittests.cfg +2 -0
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
Quoted 8 lines

s390x/unittests.cfg file = ex.elf · line 230

Quoted 5 lines
s390x/unittests.cfg +5 -0
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

Quoted 5 lines

It causes a skip, I reproduced this on a z14 by changing to z15:
SKIP topology (qemu-system-s390x: unable to find CPU model 'z15')

If we can make this more generic so the tests run on older machines it would be good, but if we can't it wouldn't break (i.e. FAIL) on older machines.

Can't we simply use "-cpu max,ctop=on" ?

Thomas

#11 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

Quoted 38 lines · Thomas Huth
Quoted 37 lines · Nico Boehr

Quoting Janosch Frank (2023-06-01 11:38:37)
[...]

Quoted 23 lines
Quoted 23 lines

   [topology]
   file = topology.elf
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)

(quoted diff) +2 -0
+# 1 CPU on socket 2
+extra_params = -smp 

1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on
-device z14-s390x-cpu,core-id=1,entitlement=low -device
z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'

s390x/unittests.cfg +4 -0
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 

1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on
-device
z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low
-device

Quoted 8 lines
Quoted 5 lines

z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

It causes a skip, I reproduced this on a z14 by changing to z15:
SKIP topology (qemu-system-s390x: unable to find CPU model 'z15')

Quoted 7 lines
Quoted 2 lines

If we can make this more generic so the tests run on older machines it would be good, but if we can't it wouldn't break (i.e. FAIL) on older machines.

Can't we simply use "-cpu max,ctop=on" ?

 Thomas

Yes we can thanks.

Pierre

#12 lore raw

Re: [kvm-unit-tests PATCH v9 2/2] s390x: topology: Checking Configuration Topology Information

In reply to Nico Boehr
Quoted 19 lines · Nico Boehr

Quoting Janosch Frank (2023-06-01 11:38:37)
[...]

Quoted 11 lines

s390x/unittests.cfg file = ex.elf · line 230

Quoted 9 lines

[topology]
file = topology.elf

s390x/unittests.cfg +7 -0
+# 3 CPUs on socket 0 with different CPU TLE (standard, dedicated, origin)
+# 1 CPU on socket 2
+extra_params = -smp 1,drawers=3,books=3,sockets=4,cores=4,maxcpus=144 -cpu z14,ctop=on -device z14-s390x-cpu,core-id=1,entitlement=low -device z14-s390x-cpu,core-id=2,dedicated=on -device z14-s390x-cpu,core-id=10 -device z14-s390x-cpu,core-id=20 -device z14-s390x-cpu,core-id=130,socket-id=0,book-id=0,drawer-id=0 -append '-drawers 3 -books 3 -sockets 4 -cores 4'
+
+[topology-2]
+file = topology.elf
+extra_params = -smp 1,drawers=2,books=2,sockets=2,cores=30,maxcpus=240  -append '-drawers 2 -books 2 -sockets 2 -cores 30' -cpu z14,ctop=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=2,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=3,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=4,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=5,entitlement=high,dedicated=on -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=65,entitlement=low -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=66,entitlement=medium -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=67,entitlement=high -device z14-s390x-cpu,drawer-id=1,book-id=0,socket-id=0,core-id=68,entitlement=high,dedicated=on

Pardon my ignorance but I see z14 in there, will this work if we run on a z13?

It causes a skip, I reproduced this on a z14 by changing to z15:
SKIP topology (qemu-system-s390x: unable to find CPU model 'z15')

If we can make this more generic so the tests run on older machines it would be good, but if we can't it wouldn't break (i.e. FAIL) on older machines.

Quoted 6 lines
Quoted 2 lines

Also, will this work/fail gracefully if the test is run with a quemu that doesn't know about topology or will it crash?

Just tried on my box, skips with:
SKIP topology (qemu-system-s390x: Parameter 'smp.books' is unexpected)

So I think we're good here.

Right, I answered about QEMU and not for kvm-unit-tests