Skip to contentSkip to conversation

iommu/arm-smmu-v3: Allow stream ID sharing for devices behind PCIe-to-PCI bridges

RFC PATCH In review Nirmoy Das 3 participants 4 messages Dec 11, 2025 – Dec 12, 2025

Subsystems (2)
lore
Share & tools
lore

Nirmoy Das

author
#0 lore raw

RFC PATCH 1/1 iommu/arm-smmu-v3: Allow stream ID sharing for devices behind PCIe-to-PCI bridges

ASPEED BMC controllers have VGA and USB functions behind a PCIe-to-PCI bridge that causes them to share the same stream ID:

\-[0005:e0]---00.0-[e1-e2]----00.0-[e2]--+-00.0 ASPEED Graphics Family
\-02.0 ASPEED USB Controller

Both devices get stream ID(0x5e200) due to bridge aliasing. Currently this USB controller gets rejected with "Aliasing StreamID unsupported", causing USB timeout errors. Allow stream ID sharing when both devices are on the same bus behind a PCIe-to-PCI bridge to fix this issue.

---
 drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c | 11 +++++++++++
 1 file changed, 11 insertions(+)
drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c +11 -0
index 2a8b46b948f05..411b8803eb46f 100644
@@ -3480,6 +3480,17 @@ static int arm_smmu_insert_master(struct arm_smmu_device *smmu,
 			if (existing_master == master)
 				continue;
 
+			/* Allow PCI devices on the same bus to share stream IDs
+			 * due to PCIe-to-PCI bridge aliasing.
+			 */
+			if (dev_is_pci(master->dev) && dev_is_pci(existing_master->dev)) {
+				struct pci_dev *pdev = to_pci_dev(master->dev);
+				struct pci_dev *existing_pdev = to_pci_dev(existing_master->dev);
+
+				if (pdev->bus == existing_pdev->bus)
+					continue;
+			}
+
 			dev_warn(master->dev,
 				 "Aliasing StreamID 0x%x (from %s) unsupported, expect DMA to be broken\n",
 				 sid, dev_name(existing_master->dev));

--
2.43.0

#1 lore raw
Quoted 10 lines · Nirmoy Das

ASPEED BMC controllers have VGA and USB functions behind a PCIe-to-PCI bridge that causes them to share the same stream ID:

\-[0005:e0]---00.0-[e1-e2]----00.0-[e2]--+-00.0 ASPEED Graphics Family
\-02.0 ASPEED USB Controller

Both devices get stream ID(0x5e200) due to bridge aliasing. Currently this USB controller gets rejected with "Aliasing StreamID unsupported", causing USB timeout errors. Allow stream ID sharing when both devices are on the same bus behind a PCIe-to-PCI bridge to fix this issue.

I don't think this is right, if you actually need stream ID sharing then I seem to recall the driver needs more changes. We don't want this in general.

IMHO ASPEED has wrong PCI config space and there isn't any actual PCI bus here that would force RID aliasing to worry about. I suggest going to ASPEED to find out and confirm that they don't actually share the RIDs and then let's quirk the PCI devices to disable alias generation in the first place.

Also, complain to them to fix their config space to report a PCIe bridge type in future devices. :)

Jason

reviewer
#2 lore raw
Quoted 7 lines · Jason Gunthorpe
Quoted 6 lines · Nirmoy Das

ASPEED BMC controllers have VGA and USB functions behind a PCIe-to-PCI bridge that causes them to share the same stream ID:

\-[0005:e0]---00.0-[e1-e2]----00.0-[e2]--+-00.0 ASPEED Graphics Family
\-02.0 ASPEED USB Controller

Quoted 8 lines
Quoted 4 lines

Both devices get stream ID(0x5e200) due to bridge aliasing. Currently this USB controller gets rejected with "Aliasing StreamID unsupported", causing USB timeout errors. Allow stream ID sharing when both devices are on the same bus behind a PCIe-to-PCI bridge to fix this issue.

I don't think this is right, if you actually need stream ID sharing then I seem to recall the driver needs more changes. We don't want this in general.

Yes, as I said on the last one not so long ago, we cannot simply cross our fingers and hope that aliasing at the SMMU StreamID level stems from something at the PCI RID level that pci_device_group() would be aware of, because there is no guarantee that RID->StreamID mappings are 1:1.

Thanks,
Robin.

Quoted 10 lines

IMHO ASPEED has wrong PCI config space and there isn't any actual PCI bus here that would force RID aliasing to worry about. I suggest going to ASPEED to find out and confirm that they don't actually share the RIDs and then let's quirk the PCI devices to disable alias generation in the first place.

Also, complain to them to fix their config space to report a PCIe bridge type in future devices. :)

Jason

author
#3 lore raw
Quoted 13 lines · Robin Murphy
Quoted 12 lines · Jason Gunthorpe
Quoted 10 lines · Nirmoy Das

ASPEED BMC controllers have VGA and USB functions behind a PCIe-to-PCI bridge that causes them to share the same stream ID:

   \-[0005:e0]---00.0-[e1-e2]----00.0-[e2]--+-00.0  ASPEED Graphics Family \-02.0  ASPEED USB Controller

Both devices get stream ID(0x5e200) due to bridge aliasing. Currently this USB controller gets rejected with "Aliasing StreamID unsupported", causing USB timeout errors. Allow stream ID sharing when both devices are on the same bus behind a PCIe-to-PCI bridge to fix this issue.

Quoted 9 lines
Quoted 3 lines

I don't think this is right, if you actually need stream ID sharing then I seem to recall the driver needs more changes. We don't want this in general.

Yes, as I said on the last one not so long ago, we cannot simply cross our fingers and hope that aliasing at the SMMU StreamID level stems from something at the PCI RID level that pci_device_group() would be aware of, because there is no guarantee that RID->StreamID mappings are 1:1.

Thanks,
Robin.

Thanks, Jason and Robin for your feedback. I will reach out to ASPEED to find out if they are actually sharing RID as suggested by Jason.

Quoted 8 lines
Quoted 8 lines

IMHO ASPEED has wrong PCI config space and there isn't any actual PCI bus here that would force RID aliasing to worry about. I suggest going to ASPEED to find out and confirm that they don't actually share the RIDs and then let's quirk the PCI devices to disable alias generation in the first place.

Also, complain to them to fix their config space to report a PCIe bridge type in future devices. :)

I will do that :)

Thanks,

Nirmoy

Quoted 3 lines
Quoted 2 lines

Jason