hwmon: (k10temp): Check range scale when CUR_TEMP register is read-write
Subsystems (2)
PATCH 1/1 hwmon: (k10temp): Check range scale when CUR_TEMP register is read-write
From: Babu Moger <[email protected]>
Spec says, when CUR_TEMP_TJ_SEL == 3 and CUR_TEMP_RANGE_SEL == 0, it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. The CUR_TEMP register is read-write when CUR_TEMP_TJ_SEL == 3 (bit 17-16).
Add the check to detect it.
Sensors command's output before the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapter
Tctl: +76.6°C <- Wrong value Tccd1: +26.5°C Tccd2: +27.5°C Tccd3: +27.2°C Tccd4: +27.5°C Tccd5: +26.0°C Tccd6: +26.2°C Tccd7: +25.0°C Tccd8: +26.5°C
Sensors command's output after the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapter
Tctl: +28.8°C <- corrected value Tccd1: +27.5°C Tccd2: +28.5°C Tccd3: +28.5°C Tccd4: +28.5°C Tccd5: +27.0°C Tccd6: +27.5°C Tccd7: +27.0°C Tccd8: +27.5°C
--- drivers/hwmon/k10temp.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-)
drivers/hwmon/k10temp.c +3 -1
@@ -75,6 +75,7 @@ static DEFINE_MUTEX(nb_smu_ind_mutex);#define ZEN_CUR_TEMP_SHIFT 21#define ZEN_CUR_TEMP_RANGE_SEL_MASK BIT(19) +#define ZEN_CUR_TEMP_TJ_SEL_MASK GENMASK(17, 16)struct k10temp_data {struct pci_dev *pdev;
@@ -155,7 +156,8 @@ static long get_raw_temp(struct k10temp_data *data) data->read_tempreg (data->pdev, ®val); temp = (regval >>ZEN_CUR_TEMP_SHIFT ) *125 ; -if (regval & data->temp_adjust_mask) +if ((regval & data->temp_adjust_mask) || + (regval &ZEN_CUR_TEMP_TJ_SEL_MASK ) ==ZEN_CUR_TEMP_TJ_SEL_MASK ) temp -=49000 ;return temp; }
Signature · 1 line
2.34.1
Quoted 36 lines · Babu Moger
From: Babu Moger <[email protected]>
Spec says, when
CUR_TEMP_TJ_SEL== 3 andCUR_TEMP_RANGE_SEL== 0, it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. TheCUR_TEMPregister is read-write whenCUR_TEMP_TJ_SEL== 3 (bit 17-16).Add the check to detect it.
Sensors command's output before the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapterTctl: +76.6°C <- Wrong value Tccd1: +26.5°C Tccd2: +27.5°C Tccd3: +27.2°C Tccd4: +27.5°C Tccd5: +26.0°C Tccd6: +26.2°C Tccd7: +25.0°C Tccd8: +26.5°CSensors command's output after the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapterTctl: +28.8°C <- corrected value Tccd1: +27.5°C Tccd2: +28.5°C Tccd3: +28.5°C Tccd4: +28.5°C Tccd5: +27.0°C Tccd6: +27.5°C Tccd7: +27.0°C Tccd8: +27.5°C
Quoted 1 line
Signed-off-by Babu Moger <[email protected]>
Applied. Please update your e-mail address configuration to avoid the following checkpatch message.
CHECK: From:/Signed-off-by: email comments mismatch: 'From: Babu Moger <[email protected]>' != 'Signed-off-by: Babu Moger <[email protected]>'
Thanks,
Guenter
Quoted 37 lines · Guenter Roeck
Quoted 36 lines · Babu Moger
From: Babu Moger <[email protected]>
Spec says, when
CUR_TEMP_TJ_SEL== 3 andCUR_TEMP_RANGE_SEL== 0, it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. TheCUR_TEMPregister is read-write whenCUR_TEMP_TJ_SEL== 3 (bit 17-16).Add the check to detect it.
Sensors command's output before the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapterTctl: +76.6°C <- Wrong value Tccd1: +26.5°C Tccd2: +27.5°C Tccd3: +27.2°C Tccd4: +27.5°C Tccd5: +26.0°C Tccd6: +26.2°C Tccd7: +25.0°C Tccd8: +26.5°CSensors command's output after the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapterTctl: +28.8°C <- corrected value Tccd1: +27.5°C Tccd2: +28.5°C Tccd3: +28.5°C Tccd4: +28.5°C Tccd5: +27.0°C Tccd6: +27.5°C Tccd7: +27.0°C Tccd8: +27.5°C
Quoted 4 lines
Quoted 1 line
Signed-off-by Babu Moger <[email protected]>Applied. Please update your e-mail address configuration to avoid the following checkpatch message.
Thank you.
Quoted 2 lines
CHECK: From:/Signed-off-by: email comments mismatch: 'From: Babu Moger <[email protected]>' != 'Signed-off-by: Babu Moger <[email protected]>'
Sure. Will update.
Quoted 3 lines
Thanks,
Guenter
Signature · 2 lines
Thanks Babu Moger