multipath-tools: identify more Storwize models
PATCH 1/1 multipath-tools: identify more Storwize models
multipath is also supported by V3500 and V3700
Cc Martin Wilck <[email protected]>
Cc Benjamin Marzinski <[email protected]>
Cc Christophe Varoqui <[email protected]>
Cc DM_DEVEL-ML <[email protected]>
Signed-off-by Xose Vazquez Perez <[email protected]>
--- libmultipath/hwtable.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
libmultipath/hwtable.c +1 -1
@@ -682,7 +682,7 @@ static struct hwentry default_hw[] = { .pgfailback = -FAILBACK_IMMEDIATE, }, { -// Storwize V5000/V7000 lines / SAN Volume Controller (SVC) +// Storwize V3x00/V5000/V7000 lines / SAN Volume Controller (SVC) // Flex System V7000 / FlashSystem V840/V9000 and 5x00/7x00/9x00/Cx00 .vendor = "IBM", .product = "^2145",
Signature · 1 line
2.51.1
Quoted 7 lines · Xose Vazquez Perez
multipath is also supported by V3500 and V3700
Cc Martin Wilck <[email protected]>Cc Benjamin Marzinski <[email protected]>Cc Christophe Varoqui <[email protected]>Cc DM_DEVEL-ML <[email protected]>Signed-off-by Xose Vazquez Perez <[email protected]>
Reviewed-by Martin Wilck <[email protected]>
Quoted 20 lines
---
libmultipath/hwtable.c | 2 +-1 file changed, 1 insertion(+), 1 deletion(-)libmultipath/hwtable.c +1
-1@@ -682,7 +682,7 @@ static struct hwentry default_hw[] = { .pgfailback = -FAILBACK_IMMEDIATE, }, { -// Storwize V5000/V7000 lines / SAN Volume Controller (SVC) + // Storwize V3x00/V5000/V7000 lines / SAN Volume Controller (SVC) // Flex System V7000 / FlashSystem V840/V9000 and5x00/7x00/9x00/Cx00
.vendor = "IBM",
.product = "^2145",