arm: mvebu: a38x: Define supported UART baudrates
PATCH 1/1 arm: mvebu: a38x: Define supported UART baudrates
Define all standard baudrates plus 3 non-standard high speed:
3125000 4000000 5150000
3125000 matches divisor 5 with 250 MHz TCLK and divisor 4 with 200 MHz TCLK. 4000000 is the rounded value for divisor 4 with 250 MHz TCLK (3906250) and divisor 3 with 200 MHz TCLK (4166666).
5150000 is the rounded value (5208333) for divisor 3 with 250 MHz TCLK. Testing showed that rounded value is more stable then exactly calculated. And it is the highest possible baudrate which is stable on A38x platform.
Any other baudrate values above 2500000 are unstable, which is reason why e.g. standard value 3000000 is not defined, and it is needed to use non-standard value 3125000.
Tested all defined UART baudrates on Turris Omnia (A38x with 250 MHz TCLK).
--- include/configs/mv-common.h | 9 +++++++++ 1 file changed, 9 insertions(+)
include/configs/mv-common.h +9 -0
@@ -39,6 +39,15 @@#define CONFIG_SYS_NS16550_COM1 MV_UART_CONSOLE_BASE#endif +#if defined(CONFIG_ARMADA_38X ) && !defined(CONFIG_SYS_BAUDRATE_TABLE ) +#define CONFIG_SYS_BAUDRATE_TABLE { 300, 600, 1200, 1800, 2400, 4800, \ + 9600, 19200, 38400, 57600, 115200, \ + 230400, 460800, 500000, 576000, \ + 921600, 1000000, 1152000, 1500000, \ + 2000000, 2500000, 3125000, 4000000, \ + 5150000 } +#endif +/* auto boot */ /*
Signature · 1 line
2.20.1
Quoted 11 lines · Pali Rohár
Define all standard baudrates plus 3 non-standard high speed:
3125000 4000000 51500003125000 matches divisor 5 with 250 MHz TCLK and divisor 4 with 200 MHz TCLK. 4000000 is the rounded value for divisor 4 with 250 MHz TCLK (3906250) and divisor 3 with 200 MHz TCLK (4166666).
5150000 is the rounded value (5208333) for divisor 3 with 250 MHz TCLK. Testing showed that rounded value is more stable then exactly calculated. And it is the highest possible baudrate which is stable on A38x platform.
Quoted 7 lines
Any other baudrate values above 2500000 are unstable, which is reason why e.g. standard value 3000000 is not defined, and it is needed to use non-standard value 3125000.
Tested all defined UART baudrates on Turris Omnia (A38x with 250 MHz TCLK).
Signed-off-by Pali Rohár <[email protected]>
Thanks,
Stefan
Quoted 15 lines
--- include/configs/mv-common.h | 9 +++++++++ 1 file changed, 9 insertions(+)include/configs/mv-common.h +2
-0@@ -39,6 +39,15 @@#define CONFIG_SYS_NS16550_COM1 MV_UART_CONSOLE_BASE#endif +#if defined(CONFIG_ARMADA_38X ) && !defined(CONFIG_SYS_BAUDRATE_TABLE ) +#define CONFIG_SYS_BAUDRATE_TABLE { 300, 600, 1200, 1800, 2400, 4800, \
include/configs/mv-common.h line 53
Quoted 10 lines
include/configs/mv-common.h +7
-0+9600 ,19200 ,38400 ,57600 ,115200 , \ +230400 ,460800 ,500000 ,576000 , \ +921600 ,1000000 ,1152000 ,1500000 , \ +2000000 ,2500000 ,3125000 ,4000000 , \ + 5150000 } +#endif +/* auto boot */ /*
Viele Grüße,
Stefan
Signature · 3 lines
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: [email protected]
Quoted 11 lines · Pali Rohár
Define all standard baudrates plus 3 non-standard high speed:
3125000 4000000 51500003125000 matches divisor 5 with 250 MHz TCLK and divisor 4 with 200 MHz TCLK. 4000000 is the rounded value for divisor 4 with 250 MHz TCLK (3906250) and divisor 3 with 200 MHz TCLK (4166666).
5150000 is the rounded value (5208333) for divisor 3 with 250 MHz TCLK. Testing showed that rounded value is more stable then exactly calculated. And it is the highest possible baudrate which is stable on A38x platform.
Quoted 7 lines
Any other baudrate values above 2500000 are unstable, which is reason why e.g. standard value 3000000 is not defined, and it is needed to use non-standard value 3125000.
Tested all defined UART baudrates on Turris Omnia (A38x with 250 MHz TCLK).
Signed-off-by Pali Rohár <[email protected]>
Applied to u-boot-marvell/master
Thanks,
Stefan
Quoted 15 lines
--- include/configs/mv-common.h | 9 +++++++++ 1 file changed, 9 insertions(+)include/configs/mv-common.h +2
-0@@ -39,6 +39,15 @@#define CONFIG_SYS_NS16550_COM1 MV_UART_CONSOLE_BASE#endif +#if defined(CONFIG_ARMADA_38X ) && !defined(CONFIG_SYS_BAUDRATE_TABLE ) +#define CONFIG_SYS_BAUDRATE_TABLE { 300, 600, 1200, 1800, 2400, 4800, \
include/configs/mv-common.h line 53
Quoted 10 lines
include/configs/mv-common.h +7
-0+9600 ,19200 ,38400 ,57600 ,115200 , \ +230400 ,460800 ,500000 ,576000 , \ +921600 ,1000000 ,1152000 ,1500000 , \ +2000000 ,2500000 ,3125000 ,4000000 , \ + 5150000 } +#endif +/* auto boot */ /*
Viele Grüße,
Stefan
Signature · 3 lines
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: [email protected]