Skip to contentSkip to conversation

arm64: dts: qcom: sm8750: Enable cpufreq cooling devices

PATCH Applied Aastha Pandey 4 participants 4 messages Apr 3 – May 7

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 arm64: dts: qcom: sm8750: Enable cpufreq cooling devices

Add cooling-cells property to the CPU nodes to support cpufreq cooling devices.

---
 arch/arm64/boot/dts/qcom/sm8750.dtsi | 8 ++++++++
 1 file changed, 8 insertions(+)
arch/arm64/boot/dts/qcom/sm8750.dtsi +8 -0
index 18fb52c14acd..417f28d8c919 100644
@@ -42,6 +42,7 @@ cpu0: cpu@0 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd0>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 
 			l2_0: l2-cache {
 				compatible = "cache";
@@ -58,6 +59,7 @@ cpu1: cpu@100 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd1>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu2: cpu@200 {
@@ -68,6 +70,7 @@ cpu2: cpu@200 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd2>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu3: cpu@300 {
@@ -78,6 +81,7 @@ cpu3: cpu@300 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd3>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu4: cpu@400 {
@@ -88,6 +92,7 @@ cpu4: cpu@400 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd4>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu5: cpu@500 {
@@ -98,6 +103,7 @@ cpu5: cpu@500 {
 			next-level-cache = <&l2_0>;
 			power-domains = <&cpu_pd5>, <&scmi_dvfs 0>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu6: cpu@10000 {
@@ -108,6 +114,7 @@ cpu6: cpu@10000 {
 			next-level-cache = <&l2_1>;
 			power-domains = <&cpu_pd6>, <&scmi_dvfs 1>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 
 			l2_1: l2-cache {
 				compatible = "cache";
@@ -124,6 +131,7 @@ cpu7: cpu@10100 {
 			next-level-cache = <&l2_1>;
 			power-domains = <&cpu_pd7>, <&scmi_dvfs 1>;
 			power-domain-names = "psci", "perf";
+			#cooling-cells = <2>;
 		};
 
 		cpu-map {

---
base-commit: cc13002a9f984d37906e9476f3e532a8cdd126f5
change-id: 20260403-cpufreq-a47fe1986469

Best regards,

Signature · 1 line
Aastha Pandey <[email protected]>
Reviewed-by on v1 1/1
#1 lore raw
Quoted 10 lines · On Fri, Apr 03, 2026 at 05:26:33PM +0530, Aastha Pandey via B4 Relay wrote:

From: Aastha Pandey <[email protected]>

Add cooling-cells property to the CPU nodes to support cpufreq cooling devices.

---
 arch/arm64/boot/dts/qcom/sm8750.dtsi | 8 ++++++++
 1 file changed, 8 insertions(+)
Signature · 2 lines
With best wishes
Dmitry
Reviewed-by
#2 lore raw
Quoted 6 lines · Dmitry Baryshkov
Quoted 5 lines · On Fri, Apr 03, 2026 at 05:26:33PM +0530, Aastha Pandey via B4 Relay wrote:

From: Aastha Pandey <[email protected]>

Add cooling-cells property to the CPU nodes to support cpufreq cooling devices.

Quoted 9 lines
Quoted 5 lines
---
  arch/arm64/boot/dts/qcom/sm8750.dtsi | 8 ++++++++
  1 file changed, 8 insertions(+)

thanks for raising this patch, looks good:

maintainer Applied
#3 lore raw
In reply to Aastha Pandey
Quoted 4 lines · Aastha Pandey

Add cooling-cells property to the CPU nodes to support cpufreq cooling devices.

Applied, thanks!

[1/1] arm64: dts: qcom: sm8750: Enable cpufreq cooling devices

      commit: 2552d5f2e51bd7e449b495d518e1f2e5252baf56

Best regards,

Signature · 1 line
Bjorn Andersson <[email protected]>