#1 lore raw
Quoted 25 lines · Rogier Wolff

Hi,

A friend of mine has a server in a datacenter somewhere. His machine is not working properly: most of his disks take 10-100 times longer to process each IO request than normal.

iostat -kx 10 output:
Device: rrqm/s wrqm/s r/s w/s rkB/s wkB/s avgrq-sz avgqu-sz await svctm %util
sdd 0.30 0.00 0.40 1.20 2.80 1.10 4.88 0.43 271.50 271.44 43.43

shows that in this 10 second period, the disk was busy for 4.3 seconds and serviced 15-16 requests during that time.

Normal disks show "svctm" of around 10-20ms.

Now you might say: It's his disk that's broken.
Well no: I don't believe that all four of his disks are broken. (I just showed you output about one disk, but there are 4 disks in there all behaving similar, but some are worse than others.)

Or you might say: It's his controller that's broken. So we thought too. We replaced the onboard sata controller with a 4-port sata card. Now they are running off the external sata card... Slightly better, but not by much.

Quoted 8 lines

Or you might say: it's hardware. But suppose the disk doesn't properly transfer the data 9 times out of 10, wouldn't the driver tell us SOMETHING in the syslog that things are not fine and dandy? Moreover, In the case above, 12kb were transferred in 4.3 seconds. If CRC errors were happening, the interface would've been able to transfer over 400Mb during that time. So every transfer would need to be retried on average 30000 times... Not realistic. If that were the case, we'd surely hit a maximum retry limit every now and then?

I had something somewhat similar happen on an Areca RAID card with four disks in RAID5. The first symptom was that the machine was extremely slow, that tracked down to IO being slow. By looking at the IO pattern it became apparent that it was very bursty, it did a few requests and then froze for about 30 seconds and then did a few requests again.

It was tracked down to one of the disks being faulty in a way that did not get it dropped out of the array. In this case when the machine was frozen and not doing any IO the activity led on the faulty disk was constantly on, when it came off a burst of IO happened.

I'm not sure what kind of a disk failure this was caused by, but you could test for it either by simply monitoring the activity leds (may not show anything in all cases, I don't know) or removing the disks one by one and testing if the problem disappears. I didn't get much log output in this case, I think the Areca driver was occasionally complaining about timeouts while communicating with the controller.