dt-bindings: renesas,tpu: Improve and json-schema conversion
Subsystems (3)
v2 cover dt-bindings: renesas,tpu: Improve and json-schema conversion
Hi all,
There are two different device tree bindings defined for the Renesas Timer Pulse Unit:
- one for using the TPU as a PWM controller (used on ARM), already using json-schema, and
- a second one for using the TPU as a clock source (used on H8/300).
The first has already been converted to json-schema.
This series improves the former, and converts the latter to json-schema. As both bindings using "renesas,tpu", both bindings are marked with the appropriate "select" logic, to check for the presence respectively absence of the "#pwm-cells" property.
Changes compared to v1:
- Keep additionalProperties, as pwm.yaml doesn't add any other properties,
- Drop unneeded "'#pwm-cells': true" from "select" section in renesas,tpu-pwm.yaml,
- Add Reviewed-by.
Thanks for your comments!
Geert Uytterhoeven (2):
dt-bindings: pwm: renesas,tpu-pwm: Improve json-schema
dt-bindings: timer: renesas,tpu: Convert to json-schema
.../bindings/pwm/renesas,tpu-pwm.yaml | 26 +++++++++ .../devicetree/bindings/timer/renesas,tpu.txt | 21 ------- .../bindings/timer/renesas,tpu.yaml | 56 +++++++++++++++++++ 3 files changed, 82 insertions(+), 21 deletions(-) delete mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.txt create mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.yaml
Signature · 12 lines
2.25.1
Gr{oetje,eeting}s,
Geert
--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- [email protected]
In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.
-- Linus TorvaldsPATCH v2 1/2 dt-bindings: pwm: renesas,tpu-pwm: Improve json-schema
- Include the general PWM controller schema,
- Make clocks, power-domains, and resets properties required.
---
v2:
- Keep additionalProperties, as pwm.yaml doesn't add any other properties.
--- .../bindings/pwm/renesas,tpu-pwm.yaml | 17 +++++++++++++++++ 1 file changed, 17 insertions(+)
Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.yaml +17 -0
@@ -58,6 +58,23 @@ required: - compatible - reg - '#pwm-cells' + - clocks + - power-domains + +allOf: + - $ref: pwm.yaml# + + - if: + not: + properties: + compatible: + contains: + enum: + - renesas,tpu-r8a73a4 + - renesas,tpu-r8a7740 + then: + required: + - resets additionalProperties: false
Signature · 1 line
2.25.1
Re: [PATCH v2 1/2] dt-bindings: pwm: renesas,tpu-pwm: Improve json-schema
Quoted 44 lines · Geert Uytterhoeven
- Include the general PWM controller schema,
- Make clocks, power-domains, and resets properties required.Signed-off-by Geert Uytterhoeven <[email protected]>---
v2:
- Keep additionalProperties, aspwm.yamldoesn't add any other properties.--- .../bindings/pwm/renesas,tpu-pwm.yaml | 17 +++++++++++++++++ 1 file changed, 17 insertions(+)Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.yaml +17
-0@@ -58,6 +58,23 @@ required: - compatible - reg - '#pwm-cells' + - clocks + - power-domains + +allOf: + - $ref: pwm.yaml# + + - if: + not: + properties: + compatible: + contains: + enum: + - renesas,tpu-r8a73a4 + - renesas,tpu-r8a7740 + then: + required: + - resets additionalProperties: falseSignature · 1 line
2.25.1
Signature · 1 line
Yosinori Sato
Re: [PATCH v2 1/2] dt-bindings: pwm: renesas,tpu-pwm: Improve json-schema
In reply to Geert UytterhoevenQuoted 12 lines · Geert Uytterhoeven
- Include the general PWM controller schema,
- Make clocks, power-domains, and resets properties required.Signed-off-by Geert Uytterhoeven <[email protected]>---
v2:
- Keep additionalProperties, aspwm.yamldoesn't add any other properties.--- .../bindings/pwm/renesas,tpu-pwm.yaml | 17 +++++++++++++++++ 1 file changed, 17 insertions(+)
Applied, thanks!
PATCH v2 2/2 dt-bindings: timer: renesas,tpu: Convert to json-schema
In reply to Geert UytterhoevenConvert the Renesas H8/300 Timer Pulse Unit Device Tree binding documentation to json-schema.
Correct clock-names, as "peripheral_clk" is the name of the supplier, and all users use "fck".
Note that there are two different bindings for the TPU, both using "renesas,tpu": this one for using the TPU as a clock source (used on H8/300), and a second use for using the TPU as a PWM controller (used on ARM). To avoid conflicts, both bindings are marked with the appropriate "select" logic, to check for the absence respectively presence of the "#pwm-cells" property.
---
v2:
- Drop unneeded "'#pwm-cells': true" from "select" section in renesas,tpu-pwm.yaml,
- Add Reviewed-by.
I have listed Sato-san as the maintainer, as he wrote the original driver and bindings.
Sato-san: Please scream if this is inappropriate ;-)
--- .../bindings/pwm/renesas,tpu-pwm.yaml | 9 +++ .../devicetree/bindings/timer/renesas,tpu.txt | 21 ------- .../bindings/timer/renesas,tpu.yaml | 56 +++++++++++++++++++ 3 files changed, 65 insertions(+), 21 deletions(-) delete mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.txt create mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.yaml
Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.yaml +9 -0
@@ -9,6 +9,15 @@ title: Renesas R-Car Timer Pulse Unit PWM Controller maintainers: - Laurent Pinchart <[email protected]> +select: + properties: + compatible: + contains: + const: renesas,tpu + required: + - compatible + - '#pwm-cells' + properties: compatible: items:
Documentation/devicetree/bindings/timer/renesas,tpu.txt deleted +0 -21
@@ -1,21 +0,0 @@ -* Renesas H8/300 Timer Pulse Unit - -The TPU is a 16bit timer/counter with configurable clock inputs and -programmable compare match. -This implementation support only cascade mode. - -Required Properties: - - - compatible: must contain "renesas,tpu" - - reg: base address and length of the registers block in 2 channel. - - clocks: a list of phandle, one for each entry in clock-names. - - clock-names: must contain "peripheral_clk" for the functional clock. - - -Example: - tpu: tpu@ffffe0 { - compatible = "renesas,tpu"; - reg = <0xffffe0 16>, <0xfffff0 12>; - clocks = <&pclk>; - clock-names = "peripheral_clk"; - };
Documentation/devicetree/bindings/timer/renesas,tpu.yaml new file +56 -0
56 lines not on this page · raw message
Signature · 1 line
2.25.1
Re: [PATCH v2 2/2] dt-bindings: timer: renesas,tpu: Convert to json-schema
Quoted 145 lines · Geert Uytterhoeven
Convert the Renesas H8/300 Timer Pulse Unit Device Tree binding documentation to json-schema.
Correct clock-names, as "
peripheral_clk" is the name of the supplier, and all users use "fck".Note that there are two different bindings for the TPU, both using "renesas,tpu": this one for using the TPU as a clock source (used on H8/300), and a second use for using the TPU as a PWM controller (used on ARM). To avoid conflicts, both bindings are marked with the appropriate "select" logic, to check for the absence respectively presence of the "#pwm-cells" property.
Signed-off-by Geert Uytterhoeven <[email protected]>Reviewed-by Rob Herring <[email protected]>---
v2:
- Drop unneeded "'#pwm-cells': true" from "select" section in renesas,tpu-pwm.yaml,
- Add Reviewed-by.I have listed Sato-san as the maintainer, as he wrote the original driver and bindings.
Sato-san: Please scream if this is inappropriate ;-)--- .../bindings/pwm/renesas,tpu-pwm.yaml | 9 +++ .../devicetree/bindings/timer/renesas,tpu.txt | 21 ------- .../bindings/timer/renesas,tpu.yaml | 56 +++++++++++++++++++ 3 files changed, 65 insertions(+), 21 deletions(-) delete mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.txt create mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.yamlDocumentation/devicetree/bindings/pwm/renesas,tpu-pwm.yaml +9
-0@@ -9,6 +9,15 @@ title: Renesas R-Car Timer Pulse Unit PWM Controller maintainers: - Laurent Pinchart <[email protected]> +select: + properties: + compatible: + contains: + const: renesas,tpu + required: + - compatible + - '#pwm-cells' + properties: compatible: items:Documentation/devicetree/bindings/timer/renesas,tpu.txt deleted +0
-21@@ -1,21 +0,0 @@ -* Renesas H8/300 Timer Pulse Unit - -The TPU is a 16bit timer/counter with configurable clock inputs and -programmable compare match. -This implementation support only cascade mode. - -Required Properties: - - - compatible: must contain "renesas,tpu" - - reg: base address and length of the registers block in 2 channel. - - clocks: a list of phandle, one for each entry in clock-names. - - clock-names: must contain "peripheral_clk" for the functional clock. - - -Example: - tpu: tpu@ffffe0 { - compatible = "renesas,tpu"; - reg = <0xffffe0 16>, <0xfffff0 12>; - clocks = <&pclk>; - clock-names = "peripheral_clk"; - };Documentation/devicetree/bindings/timer/renesas,tpu.yaml new file +56
-0@@ -0,0 +1,56 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/timer/renesas,tpu.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Renesas H8/300 Timer Pulse Unit + +maintainers: + - Yoshinori Sato <[email protected]> + +description: + The TPU is a 16bit timer/counter with configurable clock inputs and + programmable compare match. + This implementation supports only cascade mode. + +select: + properties: + compatible: + contains: + const: renesas,tpu + '#pwm-cells': false + required: + - compatible + +properties: + compatible: + const: renesas,tpu + + reg: + items: + - description: First channel + - description: Second channel + + clocks: + maxItems: 1 + + clock-names: + const: fck + +required: + - compatible + - reg + - clocks + - clock-names + +additionalProperties: false + +examples: + - | + tpu: tpu@ffffe0 { + compatible = "renesas,tpu"; + reg = <0xffffe0 16>, <0xfffff0 12>; + clocks = <&pclk>; + clock-names = "fck"; + };Signature · 1 line
2.25.1
Signature · 1 line
Yosinori Sato
Re: [PATCH v2 2/2] dt-bindings: timer: renesas,tpu: Convert to json-schema
In reply to Geert UytterhoevenQuoted 24 lines · Geert Uytterhoeven
Convert the Renesas H8/300 Timer Pulse Unit Device Tree binding documentation to json-schema.
Correct clock-names, as "
peripheral_clk" is the name of the supplier, and all users use "fck".Note that there are two different bindings for the TPU, both using "renesas,tpu": this one for using the TPU as a clock source (used on H8/300), and a second use for using the TPU as a PWM controller (used on ARM). To avoid conflicts, both bindings are marked with the appropriate "select" logic, to check for the absence respectively presence of the "#pwm-cells" property.
Signed-off-by Geert Uytterhoeven <[email protected]>Reviewed-by Rob Herring <[email protected]>---
v2:
- Drop unneeded "'#pwm-cells': true" from "select" section in renesas,tpu-pwm.yaml,
- Add Reviewed-by.I have listed Sato-san as the maintainer, as he wrote the original driver and bindings.
Sato-san: Please scream if this is inappropriate ;-)
Quoted 8 lines
--- .../bindings/pwm/renesas,tpu-pwm.yaml | 9 +++ .../devicetree/bindings/timer/renesas,tpu.txt | 21 ------- .../bindings/timer/renesas,tpu.yaml | 56 +++++++++++++++++++ 3 files changed, 65 insertions(+), 21 deletions(-) delete mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.txt create mode 100644 Documentation/devicetree/bindings/timer/renesas,tpu.yaml
Applied, thanks!