Hi Team,

In IBM we have a following requirement

* Show the connected redfish client info.
o   ClientIP
o   Client Unique Identifier(unique serial number of the client etc)

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema,
Clinet IP would be read only and will be updated once the redfish client creates the session. ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

2/ (Create the Manager object at runtime)
once the redfish client creates the session , bmcweb internally does the following

- Create the manager object whose type is "Management Controller".

- Create the ethernet interface resource manager resource and update the client IP.

   In the second option how to set the Client unique identifier which is to be given by the Redfish client

 Please let me know your thoughts on the above.

Ratan

#1 lore raw

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Ratan

Quoted 36 lines · Ratan Gupta

Hi Team,

In IBM we have a following requirement

* Show the connected redfish client info.
o   ClientIP
o   Client Unique Identifier(unique serial number of the client etc)

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema,
Clinet IP would be read only and will be updated once the redfish client creates the session. ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

2/ (Create the Manager object at runtime)
once the redfish client creates the session , bmcweb internally does the following

- Create the manager object whose type is "Management Controller".

- Create the ethernet interface resource manager resource and update the client IP.

   In the second option how to set the Client unique identifier which is to be given by the Redfish client

 Please let me know your thoughts on the above.

Ratan

#2 lore raw
Quoted 5 lines · Ratan Gupta

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Before creating OEM we are to propose it to the Redfish community. Have you asked them for their thoughts?

Quoted 11 lines

Ratan

Quoted 7 lines · Ratan Gupta

Hi Team,

In IBM we have a following requirement

* Show the connected redfish client info.
o   ClientIP >> o   Client Unique Identifier(unique serial number of the

client etc)

This confuses me, how are you getting the serial number for a connected client? If so, have you looked into data protection laws and storing Personally Identifiable Information?

Quoted 17 lines
Quoted 17 lines

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema,
Clinet IP would be read only and will be updated once the redfish client creates the session. ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

2/ (Create the Manager object at runtime)
once the redfish client creates the session , bmcweb internally does the following

Quoted 6 lines
Quoted 6 lines

- Create the manager object whose type is "Management Controller".

- Create the ethernet interface resource manager resource and update the client IP.

   In the second option how to set the Client unique identifier which is to be given by the Redfish client

I've had talks before about creating a new systems schema for the BMC specifically, so that you could expose things like bmc memory, etc. Systems also has the Ethernet schema. However this depends on what you're trying to present.

Quoted 5 lines
Quoted 5 lines

 Please let me know your thoughts on the above.

Ratan

#3 lore raw

Hi James,Ivan,Richard

The Intention of the below requirement is to help the clients to find the other connected clients in realtime.

Richard, As you mentioned in other thread

*"Or is this being to log accesses for security audits?  I think that would help me figure out what direction we should move towards."*

 It may get used for security audits but didn't think before you pointed out.

Quoted 8 lines · James Feist
Quoted 5 lines · Ratan Gupta

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Before creating OEM we are to propose it to the Redfish community. Have you asked them for their thoughts?

My plan was to ask from the openBMC community first about the requirement, If the community interested in this we can propose it to the Redfish-Forum.

Quoted 8 lines
Quoted 8 lines

Ratan

Quoted 3 lines · Ratan Gupta

Hi Team,

Quoted 7 lines
Quoted 4 lines
Quoted 4 lines

In IBM we have a following requirement

  * Show the connected redfish client info.
      o   ClientIP >>       o   Client Unique Identifier(unique serial number of the

client etc)

This confuses me, how are you getting the serial number for a connected client? If so, have you looked into data protection laws and storing Personally Identifiable Information?

Client have to give this info, it could be anything like hostname of the client, serial number of the machine etc, it is up to the client what they want to provide as part of client identifier.

Why it is needed?

Consider the below use case

=> Client(x.x.x.x) creates the session with BMC

=> BMC stores this IP(x.x.x.x)

=> Now say Client IP(x.x.x.x) got change to y.y.y.y but the session is still valid.

=> Stored IP(x.x.x.x) will not be much usable here in this scenario

=> Here Client Identifier may be usable to identify the connected client.

Let me know your thoughts here.

Quoted 18 lines
Quoted 18 lines
Quoted 18 lines

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema,
Clinet IP would be read only and will be updated once the redfish client creates the session. ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

2/ (Create the Manager object at runtime)
once the redfish client creates the session , bmcweb internally does the following

Quoted 9 lines
Quoted 6 lines
Quoted 6 lines

- Create the manager object whose type is "Management Controller".

- Create the ethernet interface resource manager resource and update the client IP.

   In the second option how to set the Client unique identifier which is to be given by the Redfish client

I've had talks before about creating a new systems schema for the BMC specifically, so that you could expose things like bmc memory, etc. Systems also has the Ethernet schema. However this depends on what you're trying to present.

Here I was proposing to create a manager object for the external clients, once they creates the session with the BMC. I am not sure what else we can set for the connected client in the manager object so I was inclined towards extending the session schema instead of creating the manager object for external clients.

Quoted 5 lines
Quoted 5 lines
Quoted 5 lines

 Please let me know your thoughts on the above.

Ratan

Ratan

#4 lore raw

Hi James, Ivan, Richard,

Please go through the mail below, I responded the queries.

Let me know if we have concern around this.

Ratan

Quoted 91 lines · Ratan Gupta

Hi James,Ivan,Richard

The Intention of the below requirement is to help the clients to find the other connected clients in realtime.

Richard, As you mentioned in other thread

*"Or is this being to log accesses for security audits? I think that would help me figure out what direction we should move towards."*

 It may get used for security audits but didn't think before you pointed out.

Quoted 8 lines · James Feist
Quoted 5 lines · Ratan Gupta

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Before creating OEM we are to propose it to the Redfish community. Have you asked them for their thoughts?

My plan was to ask from the openBMC community first about the requirement, If the community interested in this we can propose it to the Redfish-Forum.

Quoted 8 lines
Quoted 8 lines

Ratan

Quoted 3 lines · Ratan Gupta

Hi Team,

Quoted 7 lines
Quoted 4 lines
Quoted 4 lines

In IBM we have a following requirement

  * Show the connected redfish client info.
      o   ClientIP >>       o   Client Unique Identifier(unique serial number of the

client etc)

This confuses me, how are you getting the serial number for a connected client? If so, have you looked into data protection laws and storing Personally Identifiable Information?

Client have to give this info, it could be anything like hostname of the client, serial number of the machine etc, it is up to the client what they want to provide as part of client identifier.

Why it is needed?

Consider the below use case

=> Client(x.x.x.x) creates the session with BMC

=> BMC stores this IP(x.x.x.x)

=> Now say Client IP(x.x.x.x) got change to y.y.y.y but the session is still valid.

=> Stored IP(x.x.x.x) will not be much usable here in this scenario

=> Here Client Identifier may be usable to identify the connected client.

Let me know your thoughts here.

Quoted 18 lines
Quoted 18 lines
Quoted 18 lines

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema,
Clinet IP would be read only and will be updated once the redfish client creates the session. ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

2/ (Create the Manager object at runtime)
once the redfish client creates the session , bmcweb internally does the following

Quoted 9 lines
Quoted 6 lines
Quoted 6 lines

- Create the manager object whose type is "Management Controller".

- Create the ethernet interface resource manager resource and update the client IP.

   In the second option how to set the Client unique identifier which is to be given by the Redfish client

I've had talks before about creating a new systems schema for the BMC specifically, so that you could expose things like bmc memory, etc. Systems also has the Ethernet schema. However this depends on what you're trying to present.

Here I was proposing to create a manager object for the external clients, once they creates the session with the BMC. I am not sure what else we can set for the connected client in the manager object so I was inclined towards extending the session schema instead of creating the manager object for external clients.

Quoted 5 lines
Quoted 5 lines
Quoted 5 lines

 Please let me know your thoughts on the above.

Ratan

Ratan

#5 lore raw
Quoted 16 lines · Ratan Gupta
Quoted 16 lines
Quoted 3 lines

This confuses me, how are you getting the serial number for a connected client? If so, have you looked into data protection laws and storing Personally Identifiable Information?

Client have to give this info, it could be anything like hostname of the client, serial number of the machine etc, it is up to the client what they want to provide as part of client identifier.

Why it is needed?

Consider the below use case

=> Client(x.x.x.x) creates the session with BMC

=> BMC stores this IP(x.x.x.x)

Quoted 8 lines
Quoted 8 lines

=> Now say Client IP(x.x.x.x) got change to y.y.y.y but the session is still valid.

=> Stored IP(x.x.x.x) will not be much usable here in this scenario

=> Here Client Identifier may be usable to identify the connected client.

Let me know your thoughts here.

IP addresses are a terrible way of attempting to identify a client anyhow. Aren't there hundreds of implementations of authentication tokens used in web technologies? Why are we attempting to invent something new?

It seems like much of the internet world has coalesced around JWT.
https://tools.ietf.org/html/rfc7519

Signature · 1 line
Patrick Williams
#6 lore raw
Quoted 26 lines · Patrick Williams
Quoted 16 lines · Ratan Gupta
Quoted 16 lines
Quoted 3 lines

This confuses me, how are you getting the serial number for a connected client? If so, have you looked into data protection laws and storing Personally Identifiable Information?

Client have to give this info, it could be anything like hostname of the client, serial number of the machine etc, it is up to the client what they want to provide as part of client identifier.

Why it is needed?

Consider the below use case

=> Client(x.x.x.x) creates the session with BMC

=> BMC stores this IP(x.x.x.x)

Quoted 8 lines
Quoted 8 lines

=> Now say Client IP(x.x.x.x) got change to y.y.y.y but the session is still valid.

=> Stored IP(x.x.x.x) will not be much usable here in this scenario

=> Here Client Identifier may be usable to identify the connected client.

Let me know your thoughts here.

Quoted 8 lines

IP addresses are a terrible way of attempting to identify a client anyhow. Aren't there hundreds of implementations of authentication tokens used in web technologies? Why are we attempting to invent something new?

It seems like much of the internet world has coalesced around JWT.
https://tools.ietf.org/html/rfc7519

I agree with Patrick about tokens as identification, IP addresses are not usable for this purpose.

#7 lore raw
In reply to Ratan Gupta
Quoted 26 lines · Ratan Gupta

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Ratan

Quoted 17 lines · Ratan Gupta

Hi Team,

In IBM we have a following requirement

Show the connected redfish client info.
ClientIP
Client Unique Identifier(unique serial number of the client etc)

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session schema, Clinet IP would be read only and will be updated once the redfish client creates the session.

We've already some sort of it in our local env for old builds. I don't mind about client ip read only property inside session/connection inside bmcweb.

Quoted 3 lines
Quoted 3 lines

ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

What is 'ClientIdentifier' and why it should be there?

#8 lore raw
Quoted 3 lines

Show the connected redfish client info.
ClientIP
Client Unique Identifier(unique serial number of the client etc)

I'd like to know a bit more of the use case for this information. Is this done to help clients find each other in realtime? Or is this being to log accesses for security audits? I think that would help me figure out what direction we should move towards.

If this is related to auditing, then we should be thinking about how this feature might expand over time.

Cheers,
Richard

Quoted 41 lines · Ivan Mikhaylov
Quoted 24 lines · Ratan Gupta

Hi Team,

Looking for your inputs

James, How about option1 for the below use case

Ratan

Quoted 15 lines · Ratan Gupta

Hi Team,

In IBM we have a following requirement

Show the connected redfish client info.
ClientIP
Client Unique Identifier(unique serial number of the client etc)

Presently there is no way through which we can get this info.

I have following two proposal for the above requirement.

1/ (Extend the session schema)

Add the IPaddress and the client Identifier as a OEM in the session

schema,

Quoted 1 line
Quoted 1 line

Clinet IP would be read only and will be updated once the redfish

client

Quoted 1 line
Quoted 1 line

creates the session.

We've already some sort of it in our local env for old builds. I don't mind about client ip read only property inside session/connection inside bmcweb.

Quoted 3 lines
Quoted 3 lines

ClientIdentifier(Management console unique serial number etc) will be writable property and can be set by the redfish client during creation of the session or after creating the session.

What is 'ClientIdentifier' and why it should be there?

#9 lore raw
Quoted 4 lines · Richard Hanley
Quoted 3 lines

Show the connected redfish client info.
ClientIP
Client Unique Identifier(unique serial number of the client etc)

Quoted 8 lines

I'd like to know a bit more of the use case for this information. Is this done to help clients find each other in realtime? Or is this being to log accesses for security audits? I think that would help me figure out what direction we should move towards.

If this is related to auditing, then we should be thinking about how this feature might expand over time.

Not sure about Ratan's use case but ClientIP will be used in upcoming phosphor- audit work.