qemu-iotests: fix pylint 2.8 consider-using-with error
PATCH 1/1 qemu-iotests: fix pylint 2.8 consider-using-with error
pylint 2.8 introduces consider-using-with error, suggesting to use the 'with' block statement when possible.
http://pylint.pycqa.org/en/latest/whatsnew/2.8.html
Modify all subprocess.Popen calls to use the 'with' statement, except one in __init__ of QemuIoInteractive class, since
the return value is assigned to a class field and used in other methods.
--- tests/qemu-iotests/iotests.py | 63 ++++++++++++++++---------------- tests/qemu-iotests/testrunner.py | 22 +++++------ 2 files changed, 42 insertions(+), 43 deletions(-)
tests/qemu-iotests/iotests.py +31 -32
@@ -113,15 +113,14 @@ def qemu_tool_pipe_and_status(tool: str, args: Sequence[str], Run a tool and return both its output and its exit code """ stderr = subprocess.STDOUT if connect_stderr else None - subp = subprocess.Popen(args, - stdout=subprocess.PIPE, - stderr=stderr, - universal_newlines=True) - output = subp.communicate()[0] - if subp.returncode < 0: - cmd = ' '.join(args) - sys.stderr.write(f'{tool} received signal {-subp.returncode}: {cmd}\n') - return (output, subp.returncode) + with subprocess.Popen(args, stdout=subprocess.PIPE, + stderr=stderr, universal_newlines=True) as subp: + output = subp.communicate()[0] + if subp.returncode < 0: + cmd = ' '.join(args) + sys.stderr.write(f'{tool} received signal \ + {-subp.returncode}: {cmd}\n') + return (output, subp.returncode) def qemu_img_pipe_and_status(*args: str) -> Tuple[str, int]: """
@@ -237,6 +236,7 @@ def qemu_io_silent_check(*args): class QemuIoInteractive: def __init__(self, *args): self.args = qemu_io_args_no_fmt + list(args) + # pylint: disable=consider-using-with self._p = subprocess.Popen(self.args, stdin=subprocess.PIPE, stdout=subprocess.PIPE, stderr=subprocess.STDOUT,
@@ -310,22 +310,22 @@ def qemu_nbd_popen(*args): cmd.extend(args) log('Start NBD server') - p = subprocess.Popen(cmd) - try: - while not os.path.exists(pid_file): - if p.poll() is not None: - raise RuntimeError( - "qemu-nbd terminated with exit code {}: {}" - .format(p.returncode, ' '.join(cmd))) - - time.sleep(0.01) - yield - finally: - if os.path.exists(pid_file): - os.remove(pid_file) - log('Kill NBD server') - p.kill() - p.wait() + with subprocess.Popen(cmd) as p: + try: + while not os.path.exists(pid_file): + if p.poll() is not None: + raise RuntimeError( + "qemu-nbd terminated with exit code {}: {}" + .format(p.returncode, ' '.join(cmd))) + + time.sleep(0.01) + yield + finally: + if os.path.exists(pid_file): + os.remove(pid_file) + log('Kill NBD server') + p.kill() + p.wait() def compare_images(img1, img2, fmt1=imgfmt, fmt2=imgfmt): '''Return True if two image files are identical'''
@@ -334,13 +334,12 @@ def compare_images(img1, img2, fmt1=imgfmt, fmt2=imgfmt): def create_image(name, size): '''Create a fully-allocated raw image with sector markers''' - file = open(name, 'wb') - i = 0 - while i < size: - sector = struct.pack('>l504xl', i // 512, i // 512) - file.write(sector) - i = i + 512 - file.close() + with open(name, 'wb') as file: + i = 0 + while i < size: + sector = struct.pack('>l504xl', i // 512, i // 512) + file.write(sector) + i = i + 512 def image_size(img): '''Return image's virtual size'''
tests/qemu-iotests/testrunner.py +11 -11
@@ -258,17 +258,17 @@ def do_run_test(self, test: str) -> TestResult: t0 = time.time() with f_bad.open('w', encoding="utf-8") as f: - proc = subprocess.Popen(args, cwd=str(f_test.parent), env=env, - stdout=f, stderr=subprocess.STDOUT) - try: - proc.wait() - except KeyboardInterrupt: - proc.terminate() - proc.wait() - return TestResult(status='not run', - description='Interrupted by user', - interrupted=True) - ret = proc.returncode + with subprocess.Popen(args, cwd=str(f_test.parent), env=env, + stdout=f, stderr=subprocess.STDOUT) as proc: + try: + proc.wait() + except KeyboardInterrupt: + proc.terminate() + proc.wait() + return TestResult(status='not run', + description='Interrupted by user', + interrupted=True) + ret = proc.returncode elapsed = round(time.time() - t0, 1)
Signature · 1 line
2.30.2
Quoted 8 lines · Emanuele Giuseppe Esposito
pylint 2.8 introduces consider-using-with error, suggesting to use the 'with' block statement when possible.
http://pylint.pycqa.org/en/latest/whatsnew/2.8.htmlModify all subprocess.Popen calls to use the 'with' statement, except one in
__init__of QemuIoInteractive class, since
the return value is assigned to a class field and used in other methods.
Quoted 5 lines
Signed-off-by Emanuele Giuseppe Esposito <[email protected]>--- tests/qemu-iotests/iotests.py | 63 ++++++++++++++++---------------- tests/qemu-iotests/testrunner.py | 22 +++++------ 2 files changed, 42 insertions(+), 43 deletions(-)
Thanks, looks good, functionally. But I just can’t keep myself from nagging about indentation (I wouldn’t have, but flake8 says I may be justified):
Quoted 9 lines
tests/qemu-iotests/iotests.py +0
-1@@ -113,15 +113,14 @@ def qemu_tool_pipe_and_status(tool: str, args: Sequence[str], Run a tool and return both its output and its exit code """ stderr = subprocess.STDOUT if connect_stderr else None - subp = subprocess.Popen(args,
tests/qemu-iotests/iotests.py def qemu_tool_pipe_and_status(tool: str, args: Sequence[str], · line 117
Quoted 10 lines
tests/qemu-iotests/iotests.py +2
-8- stdout=subprocess.PIPE, - stderr=stderr, - universal_newlines=True) - output = subp.communicate()[0] - if subp.returncode < 0: - cmd = ' '.join(args) - sys.stderr.write(f'{tool} received signal {-subp.returncode}: {cmd}\n') - return (output, subp.returncode) + with subprocess.Popen(args, stdout=subprocess.PIPE, + stderr=stderr, universal_newlines=True) as subp:
The second line’s indentation is not aligned to the opening parenthesis of the Popen call. I’d like it better if it were.
Quoted 10 lines
tests/qemu-iotests/iotests.py +6
-0+ output = subp.communicate()[0] + if subp.returncode < 0: + cmd = ' '.join(args) + sys.stderr.write(f'{tool} received signal \ + {-subp.returncode}: {cmd}\n') + return (output, subp.returncode) def qemu_img_pipe_and_status(*args: str) -> Tuple[str, int]: """
tests/qemu-iotests/iotests.py def qemu_io_silent_check(*args): · line 239
Quoted 4 lines
tests/qemu-iotests/iotests.py +1
-0@@ -237,6 +236,7 @@ def qemu_io_silent_check(*args): class QemuIoInteractive: def __init__(self, *args): self.args = qemu_io_args_no_fmt + list(args) + # pylint: disable=consider-using-with
I think I would have added an additional comment why we need this statement (because we need to keep the Popen object around), but then again, I suppose it really is obvious.
(Wouldn’t have commented on this bit if I hadn’t replied because of the indentation. So if you think it’s obvious, no need to add a comment.)
Quoted 3 lines
tests/qemu-iotests/iotests.py +0
-0self._p = subprocess.Popen(self.args, stdin=subprocess.PIPE, stdout=subprocess.PIPE, stderr=subprocess.STDOUT,
[...]
Quoted 11 lines
tests/qemu-iotests/testrunner.py +0
-3@@ -258,17 +258,17 @@ def do_run_test(self, test: str) -> TestResult: t0 = time.time() with f_bad.open('w', encoding="utf-8") as f: - proc = subprocess.Popen(args, cwd=str(f_test.parent), env=env, - stdout=f, stderr=subprocess.STDOUT) - try:
tests/qemu-iotests/testrunner.py def do_run_test(self, test: str) -> TestResult: · line 262
Quoted 10 lines
tests/qemu-iotests/testrunner.py +2
-8- proc.wait() - except KeyboardInterrupt: - proc.terminate() - proc.wait() - return TestResult(status='not run', - description='Interrupted by user', - interrupted=True) - ret = proc.returncode + with subprocess.Popen(args, cwd=str(f_test.parent), env=env, + stdout=f, stderr=subprocess.STDOUT) as proc:
As above, the second line is (no longer) aligned to the opening parenthesis.
tests/qemu-iotests/testrunner.py def do_run_test(self, test: str) -> TestResult: · line 270
Quoted 8 lines
tests/qemu-iotests/testrunner.py +8
-0+ try: + proc.wait() + except KeyboardInterrupt: + proc.terminate() + proc.wait() + return TestResult(status='not run', + description='Interrupted by user', + interrupted=True)
And here, too.
Max
Quoted 5 lines
tests/qemu-iotests/testrunner.py +1
-0+ ret = proc.returncode elapsed = round(time.time() - t0, 1)
Quoted 9 lines · Max Reitz
Quoted 8 lines · Emanuele Giuseppe Esposito
pylint 2.8 introduces consider-using-with error, suggesting to use the 'with' block statement when possible.
http://pylint.pycqa.org/en/latest/whatsnew/2.8.htmlModify all subprocess.Popen calls to use the 'with' statement, except one in
__init__of QemuIoInteractive class, since
the return value is assigned to a class field and used in other methods.
Quoted 7 lines
Quoted 5 lines
Signed-off-by Emanuele Giuseppe Esposito <[email protected]>---
tests/qemu-iotests/iotests.py | 63 ++++++++++++++++----------------tests/qemu-iotests/testrunner.py| 22 +++++------2 files changed, 42 insertions(+), 43 deletions(-)Thanks, looks good, functionally. But I just can’t keep myself from nagging about indentation (I wouldn’t have, but flake8 says I may be justified):
No problem , I expected that there would be style problems :) I will fix the indentation and send v2.
Thank you,
Emanuele